3.Connect the other end of the
Note: The PWR and ACT LED will be ON when connect the
4.Adjust the vertical angle of directional antenna to get the maximum reading in the LEVEL and SNR display or the SNR and RSSI reading shown in the Wireless Information of the WEB server.
5.Repeat step 3 and step 4 until achieving the best reading index, then remove the antenna alignment kit.
Note: The
6.Put the console port cover back to the console port.
Note: The signal strength should be well aligned on both the Remote unit (RU) and Basestation unit (BU).
2.6 Indoor Interface Unit
The front panel LEDs of indoor interface unit and functionality are listed below:
Function | Naming | Color | Description |
Power | PWR | Green | ON: The RU power is properly applied to the indoor unit |
|
|
| OFF: The power is disconnected or the fuse is blown |
System | SYS | Green or | ON and Green: The link to the outdoor unit is established |
|
| Red | ON and RED: A serious fault of |
RSSI L, M, H | RSSI (L, | Green | ON: The receive signal strength link to remote |
| M ,H) |
| OFF: The RF propagation path to remote |
|
|
| is ON: the signal strength is Low L, M are ON: the signal strength is |
|
|
| Medium L, M, H are all ON: the signal strength is High |
|
|
|
|
Signal Quality | SNR | Green | ON: The PER is less than 8% |
|
|
| OFF: The PER is larger than 8% |
|
|
|
|
LAN | LAN 10M | Green | ON: The LAN 10/100M connection is established Flash: The LAN |
| LAN 100M | Orange | 10/100M interface is transmitting/receiving |
|
|
| OFF: The LAN 10/100M connection is not ready |
2.7 System LED Indication
For easily configuring
ODU/IDU connection fails.
END devices Init Fail.
BU init fails.
Memory Allocate Descriptor error.
H/W Allocate Descriptor error.
BU Trap Monitor Task.
Hardware Installation |