Operating the
To recall a setup:
1.Press the RCL button. The RCL button flashes.
2.Press the relevant OUT or IN button that stored the setup. In this example, press OUT 5.
3.Press the LOCK button to recall the stored setup.
7.4Acquiring the EDID
You can acquire the EDID from:
•A single connected output (see section 7.4.1)
•Several sets of inputs and outputs (see section 7.4.2)
•Several connected outputs automatically (see section 7.4.3)
•The default EDID (see section 7.4.4)
7.4.1Acquiring an EDID from a Single Connected Output
To acquire or change the EDID of a new output display:
1.Turn ON the
2.Connect the required acceptor to the output from which you want to acquire the EDID.
3.Press the EDID and STO buttons simultaneously and hold them for 3 seconds.
Both buttons flash.
4.Press the IN SELECTOR button to which the EDID will be copied. The selected input number flashes on the display.
5.Select the OUT SELECTOR button from which the EDID will be acquired.
6.Press the EDID button.
The process is complete when the display returns to normal.
7.4.2Acquiring an EDID from Several Sets of Inputs and Outputs
To acquire the EDID from several sets of inputs and outputs (for example, OUT 1 to IN 1 and OUT 6 to IN 3), do the following:
1.Power ON the
2.Connect the required acceptors to the outputs from which you want to acquire the EDID.
3.Press the EDID and STO buttons simultaneously and hold them for 3 seconds.
Both buttons flash.
12 | KRAMER: SIMPLE CREATIVE TECHNOLOGY |