Kramer Electronics VS-66hdcp user manual Default Communication Parameters, Hex Table

Page 20

 

Default Communication Parameters

9

Default Communication Parameters

 

Table 4: Default Communication Parameters

 

 

 

 

 

RS-232

 

 

 

Protocol 2000

 

 

 

 

 

 

 

Baud Rate:

9600

 

 

 

 

 

 

Data Bits:

8

 

 

 

 

 

 

Stop Bits:

1

 

 

 

 

 

 

Parity:

None

 

 

 

 

 

 

Command Format:

HEX

 

 

 

 

 

 

Example (Output 1 to Input 1):

0x01, 0x81, 0x81, 0x81

 

 

 

 

 

 

Ethernet

 

 

 

Default Settings

Reset Ethernet Default Settings

 

 

 

 

 

 

IP Address: 192.168.1.39

Power cycle the unit while holding in the Factory Reset

 

 

 

button, located on the rear panel of the unit.

 

 

TCP Port #: 5000

 

 

 

 

 

 

 

10Hex Table

Table 5 lists the Hex values for a single machine (MACHINE # 1):

Table 5: VS-66HDCP Hex Codes for Switching via RS-232/RS-485

 

OUT 1

OUT 2

OUT 3

OUT 4

OUT 5

OUT 6

IN 1

01

01

01

01

01

01

 

81

81

81

81

81

81

 

81

82

83

84

85

86

 

81

81

81

81

81

81

IN 2

01

01

01

01

01

01

 

82

82

82

82

82

82

 

81

82

83

84

85

86

 

81

81

81

81

81

81

IN 3

01

01

01

01

01

01

 

83

83

83

83

83

83

 

81

82

83

84

85

86

 

81

81

81

81

81

81

IN 4

01

01

01

01

01

01

 

84

84

84

84

84

84

 

81

82

83

84

85

86

 

81

81

81

81

81

81

IN 5

01

01

01

01

01

01

 

85

85

85

85

85

85

 

81

82

83

84

85

86

 

81

81

81

81

81

81

IN 6

01

01

01

01

01

01

 

86

86

86

86

86

86

 

81

82

83

84

85

86

 

81

81

81

81

81

81

17

Image 20
Contents Model Contents FiguresTables Introduction Getting StartedQuick Start Overview About HdcpYour VS-66HDCP Recommendations for Best PerformanceVS-66HDCP 6 x 6 DVI Matrix Switcher Front and Rear Views VS-66HDCP 6 x 6 DVI Matrix Switcher Front Panel Features VS-66HDCP 6 x 6 DVI Matrix Switcher Rear Panel FeaturesUsing the IR Transmitter Installing the VS-66HDCP in a Rack Connecting the VS-66HDCP 6 x 6 DVI Matrix Switcher Operating the VS-66HDCP 6 x 6 DVI Matrix Switcher Connecting the VS-66HDCP 6 x 6 DVI Matrix SwitcherRouting Inputs to Outputs Disconnecting the OutputsStoring and Recalling a Setup Acquiring the Edid Operating the VS-66HDCP 6 x 6 DVI Matrix Switcher Connecting to the VS-66HDCP via RS-232 Operating via the EthernetSelect Properties Technical Specifications VS-66HDCP Technical SpecificationsDefault Communication Parameters Default Communication ParametersVS-66HDCP Hex Codes for Switching via RS-232/RS-485 Hex TableKramer Protocol Protocol DefinitionsReset Video Switch Video Instruction Codes for ProtocolWould be HEX codes Outputs Only the first purchase customer may enforce this warranty 2900-000360 REV