Kramer Electronics FC-1ETHN Flash Memory Upgrade, Controlling a Kramer Machine via a Controller

Page 19

Flash Memory Upgrade

7.2 Controlling a Kramer Machine via a Controller

To control a Kramer machine via two VS-3000controllers, as the Master Mode example in Figure 5 illustrates, do the following:

1.Configure each FC-1ETHNto the Master Routing Mode (see section 6).

2.Set all the DIPs to OFF on each FC-1ETHN.

3.Connect the RS-232 port of your Kramer machine to the RS-232 port of a

FC-1ETHNvia a Null modem (alternatively, connect the RS-485 port of your Kramer machine to the ABG port1 of the FC-1ETHN)and connect the ETHERNET port of that FC-1ETHNto a LAN.

4.Connect the ETHERNET port of another FC-1ETHNto the same LAN and connect the RS-232 port of the controller to the RS-232 port of that

FC-1ETHN(alternatively, connect the RS-485 port of the controller to the ABG port1 of the FC-1ETHN).

5.Connect the ETHERNET port of another FC-1ETHNto the same LAN and connect the RS-232 port of the controller to the RS-232 port of that

FC-1ETHNvia a Null modem (alternatively, connect the RS-485 port of the controller to the ABG port1of the FC-1ETHN).

6.On each FC-1ETHN, connect the 12V DC power adapter to the power socket and connect the adapter to the mains electricity.

8 Flash Memory Upgrade

The FC-1ETHNfirmware is located in FLASH memory, which lets you upgrade to the latest Kramer firmware version in minutes! The process involves:

Downloading from the Internet (see section 8.1)

Connecting the PC to the RS-232 port (see section 8.2)

Upgrading Firmware (see section 8.3)

8.1Downloading from the Internet

You can download the up-to-date file from the Internet. To do so:

1.Go to our Web site at http://www.kramerelectronics.com and download the file: “FLIP_ FC1ETHN.zip” from the Technical Support section.

2.Extract the file: “FLIP_ FC1ETHN.zip” to a folder (for example,

1 Connect PIN A to the “A” (+) PIN, PIN B to the “B” (–) PIN, and PIN G to the “G (Ground)” PIN

12

KRAMER ELECTRONICS, LTD.

Image 19
Contents Model Figures ContentsTables Amendment to Section Figure A1 Virtual Serial Port Manager 2900-9999992 Addendum Ethernet Cross Cable Wiring Connection Getting Started IntroductionOverview Overview Achieving the Best Performance Your FC-1ETHN Ethernet ControllerUnderstanding the Kramer Configuration Manager Window Using the Kramer Configuration Manager SoftwareFC-1ETHN Configuration Manager Window FC-1ETHN Configuration Manager Window Functionality Configuring the FC-1ETHN via its Serial Port Configuring the FC-1ETHN Ethernet ControllerCrossover Cable RJ-45 Pinout Configuring the FC-1ETHN via its Ethernet portRouting Data in the Slave and Master Routing Modes Connecting the FC-1ETHN in the Slave Routing ModeConnecting the FC-1ETHN in the Master Routing Mode Controlling Kramer Machines via Ethernet using the FC-1ETHNControlling a Kramer Machine via a Computer Controlling a Kramer Machine via a Controller Flash Memory UpgradeDownloading from the Internet Upgrading Firmware Connecting the PC to the RS-232 PortOpen Configuration File window appears RS-232 Window Includes the technical specifications Technical SpecificationsOnly the first purchase customer may enforce this warranty Page 2900-104020 REV