Flash Memory Upgrade

5. Click OK and press the keyboard shortcut key F3 (or select the

Communication / RS232” command from the Settings menu, or press the keys: Alt SCR).

The “RS232” window appears. Change the COM port:

Figure 11: RS-232 Window

6. Click Connect.

In the “Atmel – Flip” window, in the Operations Flow column, the Run button is active, and the name of the chip appears as the name of the third column: AT89C51RD2.

Verify that in the Buffer Information column, the “HEX File: FC1ETHN.hex” appears.

FC1ETHN.hex

Figure 12: Atmel – Flip Window (Connected)

7. Click Run.

After each stage in the operation is completed, the check-box for that stage becomes colored green1.

When the operation is completed, all 4 check-boxes will be colored green and the status bar message: Memory Verify Pass appears2:

1 See also the blue progress indicator on the status bar

2 If an error message: “Not Finished” shows, click Run again

15

Image 22
Contents Model Contents FiguresTables Amendment to Section Figure A1 Virtual Serial Port Manager 2900-9999992 Addendum Ethernet Cross Cable Wiring Connection Getting Started IntroductionOverview Overview Your FC-1ETHN Ethernet Controller Achieving the Best PerformanceUsing the Kramer Configuration Manager Software Understanding the Kramer Configuration Manager WindowFC-1ETHN Configuration Manager Window FC-1ETHN Configuration Manager Window Functionality Configuring the FC-1ETHN Ethernet Controller Configuring the FC-1ETHN via its Serial PortConfiguring the FC-1ETHN via its Ethernet port Crossover Cable RJ-45 PinoutConnecting the FC-1ETHN in the Slave Routing Mode Routing Data in the Slave and Master Routing ModesControlling Kramer Machines via Ethernet using the FC-1ETHN Connecting the FC-1ETHN in the Master Routing ModeControlling a Kramer Machine via a Computer Controlling a Kramer Machine via a Controller Flash Memory UpgradeDownloading from the Internet Connecting the PC to the RS-232 Port Upgrading FirmwareOpen Configuration File window appears RS-232 Window Technical Specifications Includes the technical specificationsOnly the first purchase customer may enforce this warranty Page 2900-104020 REV