Kramer Electronics VP-81SIDN About the Power Connect Feature, Using Twisted Pair cables

Page 9

3.1About the Power Connect™ Feature

The Power Connect™ feature here means that digital Step-In Commanders (for example, the SID-DPand SID-DVI) do not require an independent power supply if the distance between the VP-81SIDNand the Step-In Commander does not exceed 50m (164ft). The Power Connect™ feature applies as long as the cable can carry power and the distance does not exceed 50m on standard TP cable. (Heavier gauge cable may be used to extend the Power Connect™ range).

Note: Analog Step-In Commanders (for example, the SID-VGAand SID-X1) do require independent power supplies.

3.2Using Twisted Pair cables

Kramer engineers have developed special twisted pair cables to best match our digital twisted pair products; the Kramer BC-DGKat524(CAT 5 24 AWG), the Kramer BC-DGKat623(CAT 6 23 AWG), and the Kramer BC-DGKat7a23(CAT 7a 23 AWG) cables. These specially built cables significantly outperform regular CAT 5/CAT 6/CAT 7a cables.

Note: The VP-81SIDNcannot work with unshielded cables.

3.3Using the IR Transmitter for the VP-81SIDN

You can use the RC-IR3IR transmitter to operate the VP-81SIDNvia the built in IR receiver on the front panel, or instead, via an optional external IR receiver. The external IR receiver can be located 15m (49ft) away from the device. This distance can be extended to up to 60m (197ft) when used with three extension cables.

Before using the external IR receiver, be sure to arrange for your Kramer dealer to insert the internal IR connection cable with the 3.5mm mini jack that fits into the REMOTE IR opening on the rear panel. Connect the external IR receiver to the REMOTE IR 3.5mm mini jack.

VP-81SIDN - Overview

5

 

 

Image 9
Contents VP-81SIDN Page Figures Remote Input Selection Switch Wiring Introduction Safety Instructions Getting StartedAchieving the Best Performance Recycling Kramer Products Overview About the Power Connect Feature Using Twisted Pair cablesUsing the IR Transmitter for the VP-81SIDN Feature Function Defining the VP-81SIDN 8x1 Digital Step-In SwitcherDefines the rear panel of the VP-81SIDN Switcher Installing in a Rack Connecting the VP-81SIDN 8x1 Digital Step-In Switcher Connecting the VP-81SIDN 8x1 Digital Step- In SwitcherPage Terminal Description Number Connecting to a Balanced Audio AcceptorRemote Input Selection Switch Wiring Connecting and Controlling Multiple VP-81SIDN Devices Connecting to the VP-81SIDN via RS-485To connect to the VP-81SIDN via RS-232 To connect a device with a RS-485 port to the VP-81SIDNTo connect up to four VP-81SIDN devices Connecting the Ethernet Port Directly to a PC Local Area Connection Properties Window Internet Protocol Version 6 Properties Window Control Configuration via the Ethernet Port Connecting the Ethernet Port via a Network Hub or SwitchOperating the VP-81SIDN Locally Selecting an InputTo select an input Resetting all Input Priorities to the Default Muting the Input when using Step-In CommandersSetting the Audio Output Volume Selecting an OutputMuting and unmuting the Audio Locking and Unlocking the Front Panel ButtonsTo lock and unlock the front panel buttons To mute and unmute the audio outputSetting the RS-485 Device Number Configuring and Maintaining the VP-81SIDNReading the Current RS-485 Device Number To read the current RS-485 machine numberResetting to the Factory Default Settings Setting the RS-485 Bus TerminationUpgrading the Firmware Operating the VP-81SIDN Remotely Operating the VP-81SIDN Using the Controller SoftwareFollowing table describes the main window features Feature Description Output Volume SliderAuthorized Users Step-In Software Menu BarMenu Bar Sub Menu Description Options Logging in as Admin Connecting to the DeviceTo log in as admin To switch an input to an output Switching an Input to an OutputInput Selection Switching and Selecting an Input when using the VP-81SIDNTo change the output volume Changing the Output VolumeMuting the Audio Output To mute the audio outputChanging the Priority of an Input Changing the Input and Output Button Icons and LabelsTo change an input/output button icon and label Updating the Firmware Resetting the DeviceSetting the IP Network Parameters Setting Multiple Cascaded DevicesTo set the number of devices VP-81SIDN Operating the VP-81SIDN Remotely Wiring the DGKat TP RJ-45 Connectors Wire ColorDo not use a crossed TP cable with this product Inputs Technical SpecificationsDefault Communication Parameters RS-232Ethernet Kramer Protocol 3000 Syntax ProtocolHost Message Format Device Message FormatCommand Terms Entering Commands Kramer Protocol 3000 CommandsCommand Forms Chaining CommandsLdfw Page Safety Warning