Specifications

Standard:

10BASE-T, 100BASE-TX, and 100BASE-FX

Connectors:

Port 1 - 2 RJ-45 jacks

 

Port 2 - 2 RJ-45 jacks and 1 fiber connector

Cables:

10BASE-T - Cat. 3, 4, or 5 UTP cable

 

100BASE-TX - Cat 5 UTP cable

 

100BASE-FX - 62.5/125m MM fiber

 

100BASE-FX - 9/125m SM fiber

LED indicators:

Link/Activity LED per port, Duplex/Collision

 

LED per port, Speed LED per port, Power LED

 

FX LED for Port 2

Filtering address: 1K MAC addresses shared by two ports

Filtering rate:

14,880 pps for 10M Ethernet

 

148,800 pps for 100M Fast Ethernet

Forwarding rate: 14,880 pps for 10M Ethernet

 

148,800 pps for 100M Fast Ethernet

Power:

+12VDC 800mA min.

Dimension:

144mm x 100mm x 26mm (WxDxH)

Temperature:

0o to 40oC when operating

Humidity:

10% to 90% non-condensing when operating

-3-

Image 7
Contents 10/100 Bridging Converter Installation GuidePage Trademarks Making Network Connections Table of Contents IntroductionInstallation Interpreting LED IndicatorsIntroduction Features FX LED for Port SpecificationsConnectors Port 1 2 RJ-45 jacks StandardUnpacking InstallationInstallation Installation guide Unit One AC power adapter for the switchChecking AC Power Factory Defaults Two Switched PortsConfiguration Switches Two switched ports are located on the front panelPin assignments of the jacks are defined as follows TP PortsImportant Note Jack FunctionConnection UTP Cable Type Maximum Length Connected Device SW1 setting Port Operation ModeUTP Connections Compliant UTP CablesFiber Cables Required fiber cable for the connection are Fiber Port and Fiber ConnectionModel Series Connected device Duplex type Maximum length Following table lists some applications using the deviceConnecting to Duplex type Maximum length ApplicationsFollowing figure shows the locations of the LED indicators Interpreting LED Indicators