Dukane 28A8035 manual Procedure of getting the Projector status, Example of command error

Page 27

Connection to the control signal terminal (continued)

The procedure of getting the Projector status

(1)Computer sends the command '20H'+'yyH' to Projector. (2)Projector reply the command '1xH'+'yyH'+data bytes.

The procedure of setting the Projector status

(1)Computer sends the command '3xH'+'yyH'+data bytes. (2)Projector changes it’s status.

(3)Projector reply the command '1xH'+'yyH'+data bytes which indicate status.

Caution

∙ (3) data bytes is not always same as (1) data bytes. If projector cannot realize the status of (1)

data bytes, projector set the proper status and reply this new setting data bytes or projector

 

 

reply the error reply '0xH'+'yyH'+data bytes same as (1).

When only power control (POWER COMMAND) is performed, it takes about 2~140 seconds between sending set code and receiving answering code.

The procedure of default setting the Projector status

(1)Computer sends the command '40H'+'yyH' (2)Projector changes it's status to default setting.

(3)Projector reply the command '1xH'+'yyH'+data bytes which indicate default.

The example of command error

When projector cannot accept command from PC, error code '00H'+'yyH' is sent back.

(in a case when command code '2xH', '3xH' or '4xH'+'yyH'+data is sent from PC to projector)

The example of data error

When projector cannot accept command from PC, error code with data '00H'+'yyH'+data is sent back as it is. (in a case when command code '2xH', '3xH' or '4xH'+'yyH'+data is sent from PC to projector)

When data is longer than required data code length, projector ignores excess data code.

When data is shorter than required data code length, projector sends back error code shown above.

The example of framing error

Projector sends error code '70H'+'70H' up to 10 times at intervals of 1 second until any answer is received.

The interval of command bytes and data bytes

After command code '2xH', '3xH' or '4xH' is sent from PC, if command or data is not sent within 500ms, projector sends back error command '70H'+70H'. If no answer is sent within 1 second from that time, framing error is assumed.

ENGLISH

Caution

∙ The interval of command bytes and data bytes must be over 1mS and under 500mS. If it is

under 1mS, it may be treat as framing error.

 

After projector has sent back answer code, when next command is to be sent from PC, allow for an interval of 40ms or more between answer code and other code.

27

Image 27
Contents 28A8035 For the Customers in U.K Instructions to Users Video signal cablesPower cord Before useIf any abnormality occurs Do not look directly at the lens when Lamp is litDo not install this unit in an unstable place Do not use power supplies other Than that specifiedDo not stare directly into the laser aperture Be careful in handling the power cordClean inside the unit at least once two years CleaningHandle the power cord carefully Use of batteries When you are not going to use for aCleaning the lens When you are not going to use For a long timeDo not place this unit where it gets hot VolumeContents of shipping box RGB input terminal Remote control sensor Main Power switchAC in socket Video input terminalRemote control transmitter Names and functions of each part How to insert batteriesInstallation Example of the projector and screen installationHow to use foot adjusters To project the picture Basic operationsPress the STANDBY/ON button, for 1 second To turn off the powerFreeze Function Adjustments and functions To return to the initial settingMemory function Manual Operation How to use the SET UP menuBar display items VOLUME, Bright etc Numerical display items V POSIT, H Posit etcAdjustment Item Details of adjustment AUTO-adjustmentAUTO-adjustment Confirm Screen During AUTO-adjustmentReveal Connection to the RGB signal terminal Connection to the video signal terminalsResolution Standard Display Dots KHz Type Example of computer signalInitial set signals Computer/signal Horizontal Timing µsComputer/signal Vertical Timing lines Connection to the control signal terminal Control signal terminalMouse emulation PS/2 mouse ADB Mac mouseSerial mouse RS232C cable Reference Control command tableControl command table CommunicationCommand data Example of command error Procedure of getting the Projector statusProcedure of setting the Projector status Procedure of default setting the Projector statusComputerDesk type Example of system setupConnecting various equipment AC Inlet Computer Note typeAir filter Filter cover Cleaning the air filterHow to replace lamp Remove the lamp coverLoosen two screws and pull the handle to remove Lamp Install the lamp cover and fix it using screws Reset the lamp timeLamp Action Indicator displayMessage table On-screen displayWhen you think something wrong Dimension diagram RCA Jack terminal Input terminal Input/OutputOperating guide RGB cable Legal Information Mail avsales@dukane.com St. Charles, IL Fax