LCP-10G3A4EDR
Timing parameters for SFP+ management
|
| Parameter |
|
| Symbol |
| Min. |
| Max. |
| Unit |
| Note |
| |
| TX_DISABLE Assert time | t_off |
|
| 10 |
| µsec | 1 |
| ||||||
| TX_DISABLE Negate time |
| t_on |
|
|
| 2 |
| msec |
| 2 |
| |||
| Time | to | initialize | t_2w_start_up |
|
| 300 |
| msec | 3 |
| ||||
| interfase |
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| Time to initialize |
|
| t_start_up |
|
|
| 300 |
| msec |
| 4 |
| ||
| Time | to | initialize | cooled | t_start_up_cooled |
|
| 90 |
| sec | 4 |
| |||
| module |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| Time to Power Up to Level 2 |
| t_power_level2 |
|
|
| 300 |
| msec |
| 5 |
| |||
| Time to Power Down from | T_power_down |
|
| 300 |
| msec | 6 |
| ||||||
| Level 2 |
|
|
|
|
|
|
|
|
|
|
|
|
| |
| TX_Fault assert |
|
| TX_Fault_on |
|
|
| 1 |
| msec |
| 7 |
| ||
| TX_Fault | assert for | cooled | TX_Fault_on |
|
| 50 |
| msec | 7 |
| ||||
| module |
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| TX_Fault Reset |
|
| t_reset |
| 10 |
|
|
| µsec |
| 8 |
| ||
| Module Reset |
|
| t_module_reset |
|
|
| TBD |
| msec |
| TBD |
| ||
| RS0, RS1 rate select timing |
| t_RS0_FC, |
|
|
| 500 |
| µsec |
| 9 |
| |||
| for FC |
|
|
| RS1_FC |
|
|
|
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
| |||
| RS0, | RS1 | rate select | timing | t_RS0, t_RS1 |
|
| 10 |
| msec | 9 |
| |||
| non FC |
|
|
|
|
|
|
| |||||||
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
| RX_LOS assert delay |
|
| t_los_on |
|
|
| 100 |
| µsec |
| 10 |
| ||
| RX_LOS negate delay |
|
| t_los_off |
|
| 100 |
| µsec | 11 |
|
Notes:
1)Rising edge of TX_Disable to fall of output signal below 10% of nominal.
2)Falling edge of TX_Disable to rise of output signal above 90% of nominal. This only applies in normal operation, not during start up or fault recovery.
3)From power on or negation of TX_Disable.
4)From power on or TX_Disable negated during power up, or TX_Fault recovery, until
5)From falling edge of stop bit enabling power level 2 until
6)From falling edge of stop bit disabling power level 2 until module is within power level 1 requirements.
7)From Occurrence of fault to assertion of TX_Fault.
8)Time TX_Disable must be held High to reset TX_Fault.
9)From assertion till stable output.
10)From Occurrence of loss of signal to assertion of LOS
11)From Occurrence of presence of signal to negation of RX_LOS.
11 | Revision: 0B |
| 2008/9/5 |
DELTA ELECTRONICS, INC. | www.deltaww.com |