Delta Electronics LCP-10G3A4EDR manual Digital Diagnostic Monitoring Interface

Page 14

LCP-10G3A4EDR

Digital Diagnostic Monitoring Interface

Alarm and Warning Thresholds (2-Wire Address A2h)

 

Address

 

#

 

 

Name

 

Value (Dec.)

 

Unit

 

Note

 

 

 

Bytes

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

00-01

2

 

 

Temp High Alarm

 

85 degree Celsius

 

1

 

 

02-03

2

 

 

Temp Low Alarm

 

-10 degree Celsius

 

 

 

 

 

 

04-05

2

 

 

Temp High Warning

 

80 degree Celsius

 

 

 

 

 

 

06-07

2

 

 

Temp Low Warning

 

-5 degree Celsius

 

 

 

 

 

 

08-09

 

2

 

 

Voltage High Alarm

 

3.6V

 

Volt

 

 

 

 

10-11

 

2

 

 

Voltage Low Alarm

 

3.0V

 

 

 

 

 

 

12-13

 

2

 

 

Voltage High Warning

 

3.5V

 

 

 

 

 

 

14-15

 

2

 

 

Voltage Low Warning

 

3.1V

 

 

 

 

 

 

16-17

 

2

 

 

Bias High Alarm

 

Iop+10 mA

 

mA

2

 

 

18-19

2

 

Bias Low Alarm

 

Iop-5 mA

 

 

 

 

 

 

20-21

2

 

 

Bias High Warning

 

Iop+7 mA

 

 

 

 

 

 

22-23

2

 

 

Bias Low Warning

 

Iop-3 mA

 

 

 

 

 

 

24-25

 

2

 

 

TX Power High Alarm

 

P +3dB

 

dBm

 

3

 

 

26-27

 

2

 

 

TX Power Low Alarm

 

P-3dB

 

 

 

 

 

 

28-29

 

2

 

 

TX Power High Warning

 

P +2dB

 

 

 

 

 

 

30-31

 

2

 

 

TX Power Low Warning

 

P-2dB

 

 

 

 

 

 

32-33

 

2

 

 

RX Power High Alarm

 

0dBm

 

dBm

4

 

 

34-35

2

 

 

RX Power Low Alarm

 

-13.1dBm

 

 

 

 

 

 

36-37

2

 

 

RX Power High Warning

 

-1dBm

 

 

 

 

 

 

38-39

2

 

 

RX Power Low Warning

 

-11.1dBm

 

 

 

 

 

 

40-45

 

16

 

 

Reversed

 

 

 

 

 

 

 

 

56-91

 

36

 

 

External Calibration Constants

 

 

 

 

 

 

 

 

92-94

 

3

 

 

Reversed

 

 

 

 

 

 

 

 

95

 

1

 

 

Checksum

 

 

 

 

 

5

 

 

96-97

 

2

 

 

Real Time Temperature

 

 

 

 

 

 

 

 

98-99

2

 

Real Time Supply Voltage

 

 

 

 

 

 

 

 

100-101

2

 

Real Time Tx Bias Current

 

 

 

 

 

 

 

 

102-103

2

 

Real Time Tx Optical Power

 

 

 

 

 

 

 

 

104-105

2

 

Real Time Rx Received Power

 

 

 

 

 

 

 

 

106-109

 

4

 

 

Reserved

 

 

 

 

 

 

 

 

110

 

1

 

 

Optional Status/ Control Bits

 

 

 

 

 

 

 

 

111

 

1

 

 

Reserved

 

 

 

 

 

 

 

 

112-119

 

8

 

 

Optional Set of Alarm and Warning

 

 

 

 

 

 

 

Notes:

1)TC: Case Operating temperature

2)IOP: Operating current at room temperature. The min. setting current is 0 mA.

3)P: Operating optical power of transmitter at room temperature.

4)P0: Overload optical power of receiver

PS: Sensitivity optical power of receiver

5) Byte 95 contains the low order 8bits of sum of bytes 0-94

14

Revision: 0B

 

2008/9/5

DELTA ELECTRONICS, INC.

www.deltaww.com

Image 14
Contents Description ApplicationsRecommended Operating Conditions Low Speed Electrical CharacteristicsAbsolute Maximum Ratings Optical Transmitter Characteristics TC = -5to Optical Receiver Characteristics Tc = -5to LOS D-LOS aLink Length SFP+ Transceiver Electrical Pad LayoutPin Logic Symbol Name/Description Module Electrical Pin DefinitionTXDisable Low speed electrical control pins and 2-wire interfaceTXFault RS0/RS1LCP-10G3A4EDR Recommend Circuit Schematic Package Outline Drawing for Metal Housing with Bail de-latch Latch Color IdentifierParameter Symbol Min Max Unit Timing parameters for SFP+ managementEnhanced Digital Diagnostic Interface Eeprom Serial ID Memory Contents 2-Wire Address A0h Digital Diagnostic Monitoring Interface Address Name Value Dec Unit BytesOptional Set of Alarm and Warning State/ Control BitsFeature Test Method Reference Performance Regulatory Compliance