Maintenance and Cleaning
Lamp Replacement
When the life of the projection lamp of this projector draws to an end, the LAMP REPLACE indicator lights yellow. If this indicator lights yellow, replace the lamp with a new one promptly.
This indicator lights yellow when the life of the projection lamp draws to an end.
Top Control
|
|
|
| POWER |
|
|
|
| WARNING |
|
| O | LAMP | |
|
| V |
| |
M | SELECT |
|
| REPLACE |
L |
|
|
| |
U |
|
| M |
|
O |
| + | E |
|
V |
|
|
|
CAUTION | CAUTION |
Allow a projector to cool, for at least 45 minutes before | For continued safety, replace with a lamp of the same |
you open the Lamp cover. The inside of the projector | type. Do not drop a lamp or touch a glass bulb! The |
can become very hot. | glass can shatter and may cause injury. |
Follow these steps to replace the lamp.
1 | Turn off the projector and disconnect the AC plug. Allow the |
| projector to cool for at least 45 minutes. |
2 | Loosen the screw with a screwdriver, and remove the lamp |
| cover. |
3 | Loosen 2 screws of the lamp with a screwdriver and pull out the |
| lamp by grasping the handle. |
4 | Replace the lamp with a new one and tighten the 2 screws back |
| into position. Make sure that the lamp is set properly. Replace |
| the lamp cover and tighten the screw. |
5 | Connect the AC power cord to the projector and turn on the |
| projector. |
6 | Reset the Lamp replace counter. |
| See “Lamp Replace Counter” on the next page. |
Lamp Cover | Screw |
Screw
Lamp
Screw
Handle
ORDER REPLACEMENT LAMP
Replacement lamp can be ordered through your dealer. When ordering a projection lamp, give the following information to the dealer.
● | Model No. of your projector | : | |
● | Replacement Lamp Type No. | : | |
|
|
| (Service Parts No. 610 309 2706) |
43