Maintenance and Cleaning

Lamp Replacement

When the life of the projection lamp of this projector draws to an end, the LAMP REPLACE indicator lights yellow. If this indicator lights yellow, replace the lamp with a new one promptly.

This indicator lights yellow when the life of the projection lamp draws to an end.

Top Control

 

 

 

 

POWER

 

 

 

 

WARNING

 

 

O

LAMP

 

 

V

 

M

SELECT

 

 

REPLACE

L

 

 

 

U

 

 

M

 

O

 

+

E

 

V

 

 

 

CAUTION

CAUTION

Allow a projector to cool, for at least 45 minutes before

For continued safety, replace with a lamp of the same

you open the Lamp cover. The inside of the projector

type. Do not drop a lamp or touch a glass bulb! The

can become very hot.

glass can shatter and may cause injury.

Follow these steps to replace the lamp.

1

Turn off the projector and disconnect the AC plug. Allow the

 

projector to cool for at least 45 minutes.

2

Loosen the screw with a screwdriver, and remove the lamp

 

cover.

3

Loosen 2 screws of the lamp with a screwdriver and pull out the

 

lamp by grasping the handle.

4

Replace the lamp with a new one and tighten the 2 screws back

 

into position. Make sure that the lamp is set properly. Replace

 

the lamp cover and tighten the screw.

5

Connect the AC power cord to the projector and turn on the

 

projector.

6

Reset the Lamp replace counter.

 

See “Lamp Replace Counter” on the next page.

Lamp Cover

Screw

Screw

Lamp

Screw

Handle

ORDER REPLACEMENT LAMP

Replacement lamp can be ordered through your dealer. When ordering a projection lamp, give the following information to the dealer.

Model No. of your projector

:

38-VIV208-01

Replacement Lamp Type No.

:

03-000754-01P

 

 

 

(Service Parts No. 610 309 2706)

43

Image 43
Contents Model Table of Contents Risk of Electric Shock Do not Open To the UserVoor de klanten in Nederland Safety InstructionsMoving the Projector Safety InstructionsInstalling the Projector in Proper Position Air CirculationFederal Communication Commission Notice Compliance200 240 V AC ComplianceFor Continental Europe For the U.S.A. and CanadaFeatures and Design Bottom Part Names and FunctionsFront BackTerminal Part Names and FunctionsTop Power ON-OFF buttonSignal Emission indicator Remote ControlPointer Function Laser Pointer FunctionWireless Mouse Operation Remote Control CodeRemote Control Batteries Installation Remote Control Operating RangeAdjustable Feet InstallationPositioning the Projector Connecting to a Computer InstallationTerminals Connecting to Video EquipmentProjector Turning On the Projector Basic OperationTurning Off the Projector Basic Operation Zoom AdjustmentFocus Adjustment Keystone AdjustmentDirect Operation Timer FunctionSound Adjustment No Show FunctionOn-Screen Menu Remote ControlOn-Screen Menu Top ControlMenu Bar Input Source Selection Computer InputMode Computer InputComputer System Selection AutoTo store adjustment data Computer Adjustment AutoAuto PC Adj Computer Adjustment Manual To clear adjustment data ResetMode free Display area To store adjustment dataImage button Standard Real Image Level SelectionStandard RealImage Level Adjustment Screen Size Adjustment Auto Video InputInput Source Selection Video, S-Video Input button Video Computer Video button VideoInput button Computer Video Computer button Video InputInput Source Selection Component, RGB Scart 21-Pin Component RGB ScartAV System Menu Video or S-Video Video System SelectionVideo or S-Video ComponentImage button Standard Cinema CinemaTint ColorProgressive Resets all adjustment to their previous figure Setting SettingSetting To change the code for the projector To change the code for the remote controlProjector is shut down and the Warning indicator lights red Maintenance and CleaningThen check the items below Cleaning the Projector Cabinet Maintenance and CleaningCleaning the Air Filters Cleaning the Projection LensReset the Lamp replace counter Lamp ReplacementLamp Replace Counter When the lamp replace counter is reset, the LampAppendix TroubleshootingAppendix ServiceProjector Condition Indicators and Projector ConditionInput PC AdjustImage Select Image Adjust Screen Menu TreeImage Select 575pSettingFreq Compatible Computer SpecificationsKHz Technical Specifications Terminal HDB15-PIN Pin Configuration Configurations of TerminalsTerminal DVI-I Pin Configuration MAC Adapter DVI Cable COMPONENT-VGA Cable SCART-VGA Cable USB Connector Series BTerminal Mini DIN 8-PIN Pin Configuration Optional PartsAttaching the Lens Cover Page Part No -A 610 309 1143 1AA6P1P4208-- MT3K