1. Product Specification (continued)
ACER X193HQ
5
1.3.4.3Mode Recognition
The monitor shall recognize preset modes within a range of
1.3.4.4User Display Modes
In addition to the factory
Preset timing Chart
Preset Timing Chart
Item | No | Resoulution | Band Width | Polarit | Source |
| |||
(KHz) | (KHz) | (MHz) | H | V |
| ||||
|
|
|
|
| |||||
1 | T103 | 640x480@60Hz | 31.469 | 59.941 | 25.175 | - | - | VESA |
|
2 | T173 | 640x480@72Hz | 37.861 | 72.809 | 31.500 | - | - | VESA |
|
3 | T109 | 640x480@75Hz | 37.500 | 75.000 | 31.500 | - | - | VESA |
|
4 | T182 | 640x480@66.66Hz | 35 | 66.66 | 30.24 | - | - | MAC |
|
5 | T102 | 720x400@70Hz | 31.469 | 70.087 | 28.322 | - | + | VGA |
|
6 | T104 | 800x600@56Hz | 35.156 | 56.250 | 36.000 | + | + | VESA |
|
7 | T116 | 800x600@60Hz | 37.879 | 60.317 | 40.000 | + | + | VESA |
|
8 | T117 | 800x600@72Hz | 48.077 | 72.188 | 50.000 | + | + | VESA |
|
9 | T110 | 800x600@75Hz | 46.875 | 75.000 | 49.500 | + | + | VESA |
|
10 | T108 | 832x624@74.55Hz | 49.722 | 74.55 | 57.28 | - | - | VESA |
|
11 | T118 | 1024x768@60Hz | 48.363 | 60.004 | 65.000 | - | - | VESA |
|
12 | T157 | 1024x768@70Hz | 56.476 | 70.069 | 75.000 | - | - | VESA |
|
13 | T141 | 1024x768@75Hz | 60.023 | 75.029 | 78.750 | + | + | VESA |
|
14 | T203 | 1152x870@75Hz | 68.700 | 75.000 | 84.520 | - | - |
|
|
15 | T126 | 1152x864@75Hz | 67.5 | 75 | 108 | + | + |
|
|
16 | T161 | 1280x960@60Hz | 60 | 60 | 108 | + | + | VESA |
|
17 | T179 | 1280x1024@60Hz | 63.981 | 60.020 | 108.000 | + | + | VESA |
|
18 | T131 | 1280x1024@75Hz | 79.976 | 75.025 | 135.000 | + | + | VESA |
|
19 | T339 | 1280x720@60Hz | 44.955 | 59.940 | 74.176 | + | + |
|
|
20 | T213 | 1280x800@60Hz | 49.702 | 59.810 | 83.500 | + | + |
|
|
21 | T278 | 1366x768@60Hz | 47.712 | 59.790 | 85.500 | - | - |
|
|
|
|
|
|
|
|
|
|
|
|
1.3.5Controller Requirements
1.3.5.1General Requirements
The monitor shall include a controller capable of converting the analog RGB signal from a standard SXGA resolution video controller in the CPU to a signal which can be displayed on the panel. The controller will include a PLL, A/D converters, LVDS transmitter and other circuitry necessary to perform its function. The PLL shall be stable enough to ensure that a static image from the CPU is placed in the same physical location on the flat panel in each frame.
Go to cover page
1.3.5.2Video Stretching
The monitor shall contain provisions to “stretch” the video signal, so that an input signal from the computer in any resolution smaller than 1366 x 768 is automatically expanded to fill the entire screen.
1.3.5.3Panel Timing and Interface
The controller supplied with the monitor shall control all panel timing. This controller shall adequately insulate the monitor from the computer, so that no possible combination of input signals from the computer shall cause damage to the flat panel or any other component of the monitor. The LCD panel interface shall support the TFT standard.
1.3.6DC - AC Inverter Requirements
The
1.3.7Power Supply Requirements
The AC to DC converter power supply for the monitor shall be an external AC to DC converter ”brick” This brick shall have an IEC receptacle for main power input and a pin - in
Table 2. AC TO DC Converter Requirements
Table 2
AC to DC Converter Requirements
Input Voltage Range | The operating range shall be from 90 to 132 and 195 to 265 AVC | ||
sinusoidal for all models specified. |
| ||
|
| ||
|
| ||
Input Frequency Range | Input power frequency range sha;; be from 475.to 63 Hz over the | ||
specified input voltage range. |
| ||
|
| ||
| Power consumption for the monitor shall be less than30W over the | ||
Power Consumption | specified voltage and frequency ranges. In suspend or sleep mode | ||
| the power consumption will be less than 2W. |
| |
Line Fuse | The AC input shall be fused and become electrically open as a result | ||
on an unsafe current level. The fuse many not be user replablece. | |||
| |||
|
| ||
| The power supply shall start and function properly when under full | ||
Initial Cold Start | load, with worst case conditions of input voltage, input frequenct, | ||
| operating temperature, and cold backlight lamps. | ||
|
| ||
| The inrush current must be limited to 30A when operated at | ||
Inrush Current | 120VAC, and 50A when operated at 220VAC. Inrush current is | ||
measured at an ambient temperature of 25 | oC, with the unit | ||
| |||
| temperature stabilized in the |
| |
| The power supply shall be damaged when switched ON for one | ||
Hot Start Cycle | second and OFF for one second for seven consecutive after | ||
operating for one hour at full load, 25 | oC, and nominal input line | ||
| |||
| voltage. |
| |
| The power supply shall contain protection circuitry such that the | ||
Under Voltage | application of an input voltage below the minimum specified in this | ||
table shall not cause damage to the power supply unit nor cause | |||
| |||
| failure of the input. |
| |
|
| ||
| The power supply shalloperate within IEC | ||
Line Transient | |||
| supply shall operate and comply with CE mark. |