| CONTROLLING THE MULTIPLE PRODUCT 73 | ||||
60. Backlight (Command: m g) | 63. Reading luminance values (Command: m u) |
| |||||||
To adjust the screen backlight. |
| Reads luminance values. | |||||||
|
|
|
|
|
|
|
|
| |
| Transmission | Transmission | |||||||
|
|
|
|
|
|
| |||
| [m][g][ ][Set ID][ ][Data][Cr] | [m][u][ ][Set ID][ ][FF][Cr] | |||||||
Data 00 to 64: Backlight 0 to 100 |
|
|
| ||||||
| Acknowledgement |
ENGLISH
Acknowledgement
[g][][set ID][][OK/NG][Data][x]
** It may not be supported depending on the model.
61.PC Power Control (Command: d t)
To control the PC power if the PC and the monitor are synchronized.
Transmission
[d][t][ ][Set ID][ ][Data][Cr] Data
00:Synchronized (When the monitor is off, the PC is also turned off.)
01:Not synchronized (The monitor is off but the PC is on.)
** It may not be supported depending on the model.
Acknowledgement
[t][ ][Set ID][ ][OK][Data][x] Data
00:Synchronized (When the monitor is off, the PC is also turned off.)
01:Not synchronized (The monitor is off but the PC is on.)
62.PC Power (Command: d s) Control the PC power.
Transmission
[d][s][ ][Set ID][ ][Data][Cr]
[u][][SetID][][OK/NG][Data1][Data2][Data3][Data4]
[Data5][Data6][Data7][x]
Data1
Data2
Data3
CA210 measured value Hex:
Data4
Data5
Data6
Data7
BLU measured value Hex:
*CA210 measured value is entered through the calibration procedure during final assembly. Default value is 0 before calibration.
**It may not be supported, depending on the model.
Data 00: PC is turned off.
01:PC is turned on.
**It may not be supported depending on the model.
Acknowledgement
[s][ ][Set ID][ ][OK][Data][x]
Data 00: PC is turned off. 01: PC is turned on.