74CONTROLLING THE MULTIPLE PRODUCT
ENGLISH
64.Status check (Command: s v) Check various statuses.
Transmission
[s][v][ ][Set ID][ ][Data][ ][FF][Cr]
Data 05: Check the normal operation of No.1 and No.2 luminance sensors.
06: luminance sensor being used:
07:Check the normal operation of top, bottom, or main temperature sensors.
Acknowledgement
[v][ ][Set ID][ ][OK/NG][Data][Data1][x]
When the Data is 05 Data100: All normal
01:BLU sensor 1 normal, BLU sensor 2 fail
02:BLU sensor 1 fail, BLU sensor 2 normal
03:All fail
When the Data is 06
Data100: No.1 luminance sensor is being used 01: No.2 luminance sensor is being used
When the Data is 07
Data100: All temperature sensors fail
01:Top normal, Bottom fail, Main fail
02:Top fail, Bottom normal, Main fail
03:Top normal, Bottom normal, Main fail
04:Top fail, Bottom fail, Main normal
05:Top normal, Bottom fail, Main fail
06:Top fail, Bottom normal, Main fail
07:All temperature sensors normal
When the Data is 08 Acknowledgement
[v][ ][SetID][ ][OK/NG][Data][Data1][Data2][Data3][x]
65.BLU Maintenance (Command: m t) Select ON/OFF of BLU Maintenance.
Transmission
[m][t][ ][Set ID][ ][Data][Cr]
Data 00: BLU Maintenance OFF
01:BLU Maintenance ON
**It may not be supported, depending on the model.
Acknowledgement
[t][ ][Set ID][ ][OK/NG][Data][x]
66.Mirror mode (Command: t a)
Sets the Mirror mode to Off/On/Auto.
Transmission
[t][a][ ][Set ID][ ][Data][Cr]
Data 00: Mirror mode OFF
01:Mirror mode ON
02:Mirror mode Auto
**It may not be supported, depending on the model.
Acknowledgement
[a][ ][Set ID][ ][OK/NG][Data][x]
Data1: Temperature of the top sensor area when the set is powered off.
Data2: Temperature of the bottom sensor area when the set is powered off.
Data3: Temperature of the main sensor area when the set is powered off.
When the Data is 09 Acknowledgement
[v][ ][SetID][ ][OK/NG][Data][Data1][Data2][x]
Data1
Data2
Fan Speed: Hex
** It may not be supported, depending on the model.