Mitsubishi Electronics LVP-X400U To operate projector power on Continue, Volume from the speaker

Page 14

To operate projector power ON (Continue)

Turning off the projector

9.Press the POWER button.

The message “POWER OFF? YES : PRESS AGAIN” appears on the screen.

To exit from this mode, press any button except POWER, LASER, mouse pointer, R/L-click, STILL and VOLUME + and - buttons.

10.Press the POWER button again.

The light source lamp will be turned off.

Pressing the POWER button second time will shut off the light source lamp, but the exhaust fan con- tinues to operate for 120 seconds to cool down the light source lamp and LCD panels. In this time, the lamp indicator will be turned off.

11.Turn off the main power switch. When turning off the main switch, the POWER indicator turns off.

In cases where the main power switch is acciden- tally turned off when either the intake/exhaust fan or the power source lamp is in operation, allow the unit to cool down for 10 minutes with the power turned off. Repeat step 3 when turning on the power source lamp. If the lamp does not turn on immediately, repeat this step two or three times. Replace the lamp if it should still fail to turn on.

AUTO POSITION button

When the source is selected to COMPUTER and the image is not in the right place, set the screen to the brightest display possible, then press the AUTO POSITION button on the remote control. If the image is still not in the right place.

Set screen to the brightest display as possible (e.g., full-screen display of the “Trash” window) before deploying the automatic adjustment func- tion.

If the screen saver is running, turn off the screen saver before using the automatic adjustment button.

The volume from the speaker

Press the volume + or – button to change the volume from the speaker.

The volume control bar will appear on the screen.

AUDIO

15

The volume control bar will disappear about 10 seconds after releasing the volume buttons.

The volume buttons do not work when MENU selection bar or MENU is displayed.

The volume from the AUDIO OUT jack is also changed by pressing the volume + or – button. (Variable LINE OUT)

If the high level of audio signal, for example DVD is supplied into COMPUTER AUDIO IN terminal, the speaker out may be distorted.

AV mute

Image and audio are temporarily muted by pressing the MUTE button. To restore the image and audio to the normal mode, press the MUTE button again.

To prevent the damage of the LCD, the image and audio will be restored automatically to the normal mode, 10 minutes after setting the AV mute mode.

The audio from the AUDIO OUT jack is also muted by pressing the MUTE button.

Caution:

When you have finished using this equipment, wait 120 seconds for the exhaust fans to stop. Then turn off the main switch and unplug the power cable from the wall outlet, for safety purposes.

After the lamp is turned off, the lamp cannot be switched on again for 60 seconds as a precaution- ary measure. It will take another 60 seconds before the lamp indicator goes off. If you wish to turn on the projector again, wait until the indicator is off then press the POWER button.

The exhaust fan rotates faster when the tempera- ture around the projector rises.

When the temperature around the projector becomes too high, the sign “TEMP!!” blinks red on the screen. If the temperature stays too high, the lamp will be shut off automatically .

The projector automatically shuts off when the lamp is used up in about 1,500 hours and cannot be used until the lamp is replaced and the internal timer is reset. See page 23.

EN – 14

Image 14
Contents English Français Deutsch Italiano Español X400When using the projector in Europe Compliance NoticeContents Important safeguards If you use incorrect voltage, it can lead to fire It can lead to fire or electric shockIt can lead to fire Overview Terminal board640 660 nm laser equipment This remote control is class 2 max. output 1 mW laser diodeAbout laser beam Beam Divergence 3m distance about 5.0mm x 3.0mm ±1.5mmOperation area for wireless control system Using the remote controlBattery installation Using the wired remote controlScreen InstallationOrientation of the projector Projector + DVD player or Hdtv decoder Basic connectionsProjector + AV equipment For computer with DVI terminal For using MacintoshProjector + Personal computer About DDC For DVI connectionGetting ready for projection Adjusting the angle of projectionPreparing the projector for operation Button To operate projector power onAuto Position Turning off the projector To operate projector power on ContinueVolume from the speaker AV muteMenu operation Basic operationPicture InstallationMenu operation OptionUser memory for signal setting SignalColor temperature Picture adjustmentAdjusting the image Color matrixAdjustment from personal computer Picture adjustment XGA85Picture in Picture PinP Advanced features for presentationExpand StillProjector + computer with USB connector Advanced features for presentationMouse remote control Projector + computer with PS/2 connectorHow to reset the operation time meter Lamp replacementInterval of the lamp replacement Cleaning the projector and the ventilation slots MaintenanceCleaning the air-filter Cleaning the lensTroubleshooting Abnormal condition IndicatorsNormal condition Specifications Dimensional drawings mm SpecificationsConnectors Replacement part Option / Not included in the box871D293A40 Interface Control projector by using a personal computerControl command diagram How to set the grade Operation commandsComputer input commands Control sequenceExample Display Menu selection bar. is for Ascii code Volume commandsRemote commands Menu setting commands Example 1 Set the Auto Power on to onReading command diagram