Mitsubishi Electronics DX-ZD6UE Specifications, Control input/output terminals and circuits

Page 20

Specifications

General

 

Rated Power Supply:

100 to 240 V AC, 50/60 Hz

Rated Input:

0.75 - 0.4 A (100-240 V)

Operating Temperature:

41 °F-104 °F (5 °C to 40 °C)

Relative Humidity:

Max. 80 (%)

Altitude:

Max. 2000 (m)

Dimensions:

424 (Width) x 361 (Depth) x 49 (Height) (mm)

Weight:

6.3 kg (with 2 HDD mounted)

Control terminals

 

CONT IN

Input terminal linked with the power supply of the recorder

CONT OUT

Output terminal linked with the power supply of the recorder

 

(CONT OUT is the through output of CONT IN.)

GND (Ground)

For grounding

TEMP ALM

Output terminal for detecting abnormal temperature (open collector output)

 

Active: “Low” level voltage output, Max. current 7 mA DC.

 

Non active: Open, Max. voltage 24 V DC.

FAN ALM

Output terminal for detecting fan error (open collector output)

 

Active: “Low” level voltage output, Max. current 7 mA DC.

 

Non active: Open, Max. voltage 24 V DC.

HDD ALM

Output terminal for detecting HDD error (open collector output)

 

Active: “Low” level voltage output, Max. current 7 mA DC.

 

Non active: Open, Max. voltage 24 V DC.

CONT IN

Reserved.

CONT OUT

Reserved.

EXTERNAL CONTROL:

When set to ON: Power is supplied to the HDD when 12V is applied to the input terminal linked with the power supply.

When set to OFF: Power is always supplied to the HDD.

Serial bus terminal

 

 

Serial bus terminal (2 terminals)

(Only DX-ZD6UE is connectable.)

Accessories:

USB2.0 cable

1

 

Control cable

1

 

Screws

8

 

User’s manual (this manual) 1

 

Power cord

3

Control input/output terminals and circuits

TEMP ALM terminal

FAN ALM terminal

HDD ALM terminal

• Output Circuit

Output terminal

GND terminal

<Interface circuit inside the unit>

Design and specifications are subject to change without notice.

20

Image 20
Contents DX-ZD6UE Unplug the Power Cord During a Long Absence Mains Lead Connection DisclaimerFeatures/Contents Major operations and their functions Front viewRear view English Connection example ConnectionsConnectable recorders Precautions for connection Connections StartupSet the ID rotary switch to the desired number Setting the ID number of this unitSetting the ID number of this unit Mode selection Setting the mode of this unitHDD operation mode Step Precautions for replacing the HDD Replacing the HDDRemoving the HDD Remove the screws Remove the front coversRemove the cords Pull out the HDD tray halfwayRemove the HDD Attaching the HDD Attach the new HDD onto the HDD tray with 4 screwsAttach the front covers Troubleshooting Diagnosis by HDD indicatorsDescription of problem Please check the following TroubleshootingMaintenance Specifications Control input/output terminals and circuitsMitsubishi Digital Electronics AMERICA, INC