8.Remove the defective tube:
•Press the flaps backwards to release the tube.
•Pull the tube gently out of the holders and then sideways out of the scanner.
9.Insert the replacement tube and mount it into the holders making sure that it is properly held in place by the flaps.
10.Connect the plug (F).
11.IMPORTANT: The "T" on the lamp board cover (G) indicates the socket for the transparencies tube.
12.Lower the feed table (E).
13.Mount the side panels (C) and (D), the screws (B) and the front panel (A) following the reverse of the procedure used when removing them.
NOTE! When mounting the front panel (A) make sure to give it a firm push at the bottom to click it properly into position.
14.Turn on the scanner and check function of the new tube.
English
Cleaning the External Surface of the Scanner
If the external surface of the scanner becomes dirty, then clean it with a damp cloth. Be careful not to get any moisture inside the scanner or on any of the connectors. Do not use alcohol or other solvents.
Disposal
If you need to dispose of the scanner, it must be delivered to an authorized waste plant for electronics equipment.