ENGLISH
RS-232C Interface (Continued)
Command Format
The command between this unit and the computer consists of“Header”,“Unit ID”,“Command”,“Data” and “End”.
●Header (1 byte), Unit ID (2 bytes), Command (2 bytes), Data (n bytes), End (1 byte) ■ Header
This binary code indicates the start of communication.
Binary code | Type | Description |
|
|
|
21 | Operating command | PC → This unit |
|
|
|
3F | Response command | PC → This unit |
|
|
|
40 | Reference command | This unit → PC |
|
|
|
|
| This unit → PC |
06 | ACK | (When the command is accepted without error, it |
|
| returns to PC) |
|
|
|
■Unit ID
This code specifies the unit. The binary code is fixed at “8901”.
■Command and data
Operating command and data (Binary code)
Command | Type | Description | |
|
|
| |
0000 | Connection check | Check whether communication is available between this | |
unit and the PC during standby. | |||
|
| ||
|
|
| |
|
| During standby | |
5057 | Power supply | 31: Turn on the power. | |
During power on | |||
|
| ||
|
| 30: Turn off the power. (Standby mode) | |
|
|
| |
|
| During power on | |
4950 |
| 32: COMP. | |
Input | 33: PC RS50 RS506 | ||
|
| 36: HDMI 1 | |
|
| 37: HDMI 2 | |
|
|
| |
5243 | Remote Control | Sends the same code as the supplied remote control. | |
● “Remote control code” (Reference page: 70) | |||
|
| ||
|
|
|
Others
69