Getting Started

Select a location that allows for 3" clearance behind the power supply, and comfortable reach of the front panel controls and cell connections. Do not block the vented area of the case - on the front bottom of the unit, or the fan area at the rear. Connect the power supply to a 3-prong grounded AC outlet, using the AC cord provided with the unit only. Connect the electrophoresis apparatus to the power supply, making sure to match the red positive lead to the red positive jack, and the black negative lead to the black negative jack. Similarly, connect one or more electrophoresis apparatus to the power supply if you plan to run more than one in parallel. Power the unit on using the AC power switch located at the rear of the unit, next to the AC line cord entry.

Function keys

black negative jacks

Exit key

 

Clear key

 

 

 

black negative jacks

 

 

 

 

red positive jacks

Run key

Stop key

 

red positive jacks

 

 

 

Pause key

 

 

 

 

 

gray ON/OFF key

 

 

 

Figure 1. Front Panel Controls

Using the Power Supply

Press the dark gray key on the front of the unit to enable/disable the control logic. The LCD display will illuminate and show the values of the last saved run setup. The FB200 preserves the run settings each time you start a run. One set of conditions is saved for each mode, constant voltage or constant current. The setpoint value, limit parameter, time duration, and power-fail restart settings are all saved. This allows convenient setup for repetitive runs.

To change the control mode, press the Exit key. From the resulting screen, select either constant volts or constant amps using the function keys to the right of the display.

After selecting a control mode, either constant voltage or current, and setting the limit and timed run parameters if desired (see Constant Voltage/Current Operations) press the Run key to energize the power supply output. The power supply output will ramp up to the appropriate setpoint, while not allowing the limit parameter to be exceeded. If the limit parameter should be exceeded, then the power supply will crossover control modes, making the limit parameter the new control

FB200-2 MANUAL

Page 5

7608175 Rev A 8/02

Image 6
Contents FB200-2 Electrophoresis Power Supply Operator’s ManualFisher Biotech FB200 Electrophoresis Power Supply Table of ContentsSafety Considerations Unpacking the Power Supply IntroductionDC output Power SpecificationsAC input Power EnvironmentalUsing the Power Supply Getting StartedConstant Voltage Operations Constant Current OperationsTimed Operations Automatic Power-fail Restart CleaningTroubleshooting and Error Indications Replacing a fuseFB200 Warranty Statement ComplianceReplacement Parts AccessoriesTechnical Support Table des matières Considérations de sécurité Déballage de l’alimentation électrique Environnement SpécificationsCourant d’entrée CA Courant de sortie CCMise en route Utilisation de l’alimentation électriqueOpérations à tension constante Opérations à intensité constanteOpérations à durée déterminée Redémarrage automatique en cas de coupure de courantNettoyage Remplacement d’un fusible Dépannage et indications d’erreurGarantie du FB200 ConformitéPièces de rechange Fisher Scientific Park Lane Pittsburgh, PA 15275 USAFisher Biotech FB200-2 Elektrophorese-Netzteil InhaltsverzeichnisSicherheitstechnische Hinweise Einführung Auspacken des NetzteilsUmfeldbedingungen Technische DatenNetzeingangsleistung GleichstromausgangsleistungEinstieg Verwenden des NetzteilsBetrieb bei Dauerspannung Betrieb bei DauerstromZeitgesteuerter Betrieb Automatischer Neustart bei StromausfallReinigung Fehlersuche und Fehlermeldung Auswechseln einer SicherungFB200 Garantieerklärung KompatibilitätErsatzteile Contenido Consideraciones de seguridad Introducción Desembalaje de la fuente de alimentaciónMedioambientales EspecificacionesPotencia de entrada de CA Potencia de salida de CCPara empezar Uso de la fuente de alimentaciónOperaciones a voltaje constante Operaciones a corriente constanteOperaciones temporizadas Reinicio automático tras un fallo en la alimentaciónLimpieza Diagnóstico e indicaciones de error Sustitución de un fusibleDeclaración de garantía del FB200 Conformidad Conformidad EMC Compatibilidad electromagnéticaPiezas de repuesto Fisher Scientific Park Lane Pittsburgh, PA 15275, EE.UUFB200-2 Electrophoresis Power Supply Part No Rev a