RS-232C ADJUSTMENT MODE
Interface
1)Connector:
2) Pin Layout:
Pin No. | Signal |
|
|
1 | NC (not connected) | 1 | 5 |
2 | TxD (Transmit Data) |
|
|
3 | RxD (Receive Data) |
|
|
4 | NC (not connected) |
|
|
5 | GnD |
|
|
6 | NC (not connected) | 6 | 9 |
7 | NC (not connected) |
|
|
8 | RTS (Request to Send) |
|
|
9 | NC (not connected) |
|
|
3)Baud Rate: 9600 bps (standard)
(switchable to 1200, 2400, 4800, 19200, 38400 bps)
NOTE: The baud rate of this display should be set to match the baud rate of the computer. Also, when the
4)Data Format
Start:
Data:
Parity: 0 (no parity)
Stop:
5) Connection | Control PC | Plasma Display | Control PC | Plasma Display |
| ||||
| (with D25 serial port ) | (with D9 serial port) | ||
| RXD 3 | 2 TXD | RXD 2 | 2 TXD |
| TXD 2 | 3 RXD | TXD 3 | 3 RXD |
| CTS 5 | 8 RTS | CTS 8 | 8 RTS |
| GND 7 | 5 GND | GND 5 | 5 GND |
Straight Cable
*
NOTE: Computer manufacturers may not use the same pin assignments. In case of communication difficulties, check pin functions not just pin numbers.