TANDBERG TC2.1 manual What’s new

Page 5

Profile series with Codec C60

Administrator Guide

Contentsontents

IntroductionIntIntr ctition

GetGettinging startstarted

AboutAbout tthe menuss

The setSettingsings menumenu

TheS ttingsSettingsLibrarylibrary

Camerasa eras

AppenAppendicesic

ContactContact us

What’s new

What’s new this guide

The TANDBERG Profile 65” with Codec C60 has been added to the Profile series and is described in this guide.

What’s new in this software version

The latest software versions for the Codec C60 is TC2.1. The Advanced configurations menu changes are described on this page.

For a complete overview of the news and changes from TC2.0 to TC2.1 we recommend reading the software release notes TANDBERG TC Software Release Notes (TC2).

Go to: http://www.tandberg.com/docs

Advanced configuration—­Settings added

Standby StandbyAction

Value space: <None/PrivacyPosition>

None: No action.

PrivacyPosition: Turns the camera to a sideways position for privacy.

NOTE! The settings within the Experimental menu can be used ‘as is’. The content of the Experimental menu will change in future software releases.

Experimental Audio Input Microphone [1..4] EchoControl HighPassFilter

Value space: <On/Off>

Experimental Video OptimalDefinition Profile

Value space: <Normal/Medium/High>

See the table below to find when to choose Normal, Medium or High for the optimal definition profile.

Advanced configuration—­Value space changed

SerialPort BaudRate

Previous version: <9600/19200/38400/115200>

New value space: <9600/19200/38400/57600/115200>

SystemUnit MenuLanguage

Previous version: <English/Norwegian/Swedish/German/ French/Italian/Japanese/Chinese/Russian/Spanish/ Korean/Turkish>

New value space: <English/Norwegian/Swedish/German/ French/Italian/Japanese/Russian/Spanish/Korean/ Finnish/ChineseSimplified/ChineseTraditional/ PortugueseBrazilian/Turkish/Polish>

Advanced configuration—­Removed settings

The Experimental settings are subject to change without notice. They can be used “as is”. In version TC2.1 the following settings are removed:

Experimental Audio Input Line [3..4] Equalizer Mode Experimental Audio Input Line [3..4] Equalizer Number Experimental Audio Output Line [3..6] Equalizer Mode Experimental Audio Output Line [3..6] Equalizer Number Experimental SoftwareUpgrade Mode

Experimental SoftwareUpgrade ServerAddress

Experimental > Video > Optimal definition, for systems supporting 1080p

 

w288p30

w448p30

w576p30

720p30

1080p30

 

 

 

 

 

 

Normal

256kbit/s

512 kbit/s

768 kbit/s

1152 kbit/s

2560 kbit/s

Medium

128kbit/s

384 kbit/s

512 kbit/s

768 kbit/s

1920 kbit/s

High

128kbit/s

256 kbit/s

512 kbit/s

768 kbit/s

1472 kbit/s

Experimental > Video > Optimal definition, for systems supporting 720p60

w144p60

w288p60

w448p60

w576p60

720p60

Normal

128kbit/s

512 kbit/s

1152 kbit/s

1472 kbit/s

2240 kbit/s

Medium

128kbit/s

384 kbit/s

768 kbit/s

1152 kbit/s

1472 kbit/s

High

128kbit/s

256 kbit/s

512 kbit/s

768 kbit/s

1152 kbit/s

D14324.04—DECEMBER 2009

5

Image 5
Contents With Codec C60 Profile Profile 52 DualThis guide? Table of ContentsAppendices This chapter ChapterWhat’s new Trademark Intellectual Property RightsDisclaimer Patent InformationSafety Instructions Safety InstructionsEMC A-Class declaration FCC rules 15B, acc. to Class a limitsTANDBERG’s Environmental Policy Environmental IssuesGetting started Tandberg Profile System overviewSystem overview Dual monitor Tandberg Profile 52 DualWith batteries With cables LAN Codec cable configurationBatteries Using the Remote ControlCall KEY Using the Remote Control,Verify IP address settings Initial configurationsPassword protection of the Advanced menu Waking up the systemAdding the system to the network Verify your settingsAdjusting the date and time settings How to set the menu password Setting a menu passwordAbout the menus About the menus Settings menuHome menu Advanced menuSystem settings menus Advanced menus How to change a valueDescription of each setting Search Advanced configuration menuSearch functionality Advanced menu How to change the menu passwordSetting a menu password System settings library Audio settings Description of the System settingsAudio Output Line 1. Mode On/Off Audio Input Microphone 1. Mode On/OffAudio Output Hdmi 1. Mode On/Off Audio SoundsAndAlerts KeyTones Mode On/OffCamera settings Conference settings H323 Profile settings Network settings Network 1. IEEE8021X Mode On/Off Network 1. IPv4 QoS Mode Off/DiffservNetwork 1. IEEE8021X Password S 0 Network 1. IEEE8021X Eap Peap On/OffNetwork Services settings NetworkServices SIP Mode On/Off NetworkServices NTP Mode Auto/ManualNetworkServices Snmp CommunityName S 0 NetworkServices Snmp Mode Off/ReadOnly/ReadWriteSerial Port settings Phonebook settingsProvisioning settings SIP Profile settings Standby settings Time TimeFormat 24H/12H Time settingsVideo DefaultPresentationSource Video settingsVideo Encoder Threshold60fps Video Input Source 1. CameraControl CameraIdVideo Input Source 1 Connector Hdmi Video Input Source 1. CameraControl Mode On/OffVideo Input Source 2 Connector HDMI/DVI Video Input Source 3 Connector DVI/Composite/YCVideo MainVideoSource Video OSD Mode On/OffVideo Monitors Single/Dual Video OSD OutputVideo Selfview On/Off Video Output Composite 3 Resolution PAL/NTSCExperimental menu, Experimental CapsetFilter S 0 Experimental settingsExperimental Audio Output Line 1. Equalizer Mode On/Off Cameras Hdmi and HD-SDI PrecisionHD 1080p cameraKensington lock Cascaded camerasPrecisionHD 1080p Camera, Connecting the cameraHdmi cable HD-SDI cableBest view-Face recognition Using Best viewLine voltage frequency DIP switch settings for video output formatsVideo output formats Appendices Physical conditions General room guidelinesRoom equipment Environmental considerationsNatural communication Audio qualityBest audio quality to all participants Making eye contactGeneral recommendations for the room layout Guidelines for meeting room setupShows the PC presentation and the participants Sharing a PC presentationOther presentation sources Microphone Press the key to toggle the microphones on/off Tandberg Remote Control TRC5Setting the menu password Password protectionSetting the codec administrator password Startup script Login to the codecAdding a startup script About the startup script fileSystem info Password protection of the web interfaceWeb interface Web interface, Upgrade softwareExpanded view Advanced configurationSearch functionality Advanced configuration, search functionalityWallpaper Dial Hang up CallUpload certificates XML files ConfigurationHistorical log files Current log files Logs Log filesRelease key Add release keyDnam Amplifier Tandberg Dnam for Profile 42/52Dnam Loudspeaker Cabinet Tandberg Dnam for Profile Media capabilities supported in SIP Supported RFCs in SIPCurrent RFCs and drafts supported in SIP China RoHS table Profile CE Declaration for Tandberg ProfileProfile 42 with standalone foot DimensionsProfile 42 with wall mount foot Profile 42 with wheelbase foot Profile 52 with standalone foot Profile 52 with wall mount foot Profile 52 with wheelbase foot Profile 52 Dual with standalone foot Mounting Profile wall mount setupProfile 65 with standalone foot Profile 65 with wall mounting foot PrecisionHD 1080p camera Unit Delivered Complete with Technical specifications for Profile 42/52SIP Embedded Encryption Technical specifications For Profile 42/52,Technical specifications for Profile Technical specifications For Profile 65, ContactCo ctt usus