TANDBERG D1392602 manual ProductType Uptime Software Version Name ReleaseDate, o Name

Page 25
<ProductType>

TANDBERG Video Portal

Data port Command Interface User Guide

Status format:

<ProductType>

<Uptime>

<Software

Version>

Name>

ReleaseDate>

Configuration Telephony:> VideoTelephony:>

<Hardware : Version> SerialNumber> MainBoard> AdditionalBoard> Configuration:

PRI>

TemperatureCelcius>

TemperatureFahrenheit>

---

Parameters:

ProductType, the name of the product, e.g. Video Portal

Uptime, the time the system is running since the last reboot in seconds

Software

oVersion, the unique name of the software

oName,

oReleaseDate, the time and date of the build of this software

oConfiguration

Telephony, the amount of supported voice channels

VideoTelephony, the amount of supported video channels

Hardware

oVersion, software ID

oSerialNumber, software serial number o MainBoard, the ID of the main board

o AdditionalBoard, indicates extra boards in the box o Configuration:

PRI, the amount of PRIs in the target system

BRI, the amount of BRIs in the target system

TemperatureCelcius, temperature of the main board in Celcius

TemperatureFahrenheit, temperature of the main board in Fahrenheit

Example of SystemUnit feedback: *s SystemUnit:

ProductType: "TANDBERG Video Portal"

Uptime: 15123

Software:

Version: "R3.0Beta2 (TEST SW)"

Name: "test"

ReleaseDate: "2007-03-21, 17:54"

Configuration:

Telephony: 0

VideoTelephony: 0

Hardware:

Version: "EP 1.0"

SerialNumber: "43A00001"

MainBoard: ""

AdditionalBoard: ""

D1392602

25

Image 25
Contents D1392602 Software version VTANDBERG Video Portal Data port Command Interface User Guide Data port Command Interface User Guide3. CONNECTING TO THE DATA PORT COMMAND INTERFACE USING TELNET Table of Contents4. THE TANDBERG VIDEO PORTAL COMMANDS Command format1. Introduction 2.1. Hardware and Cabling 2.2. TroubleshootingTANDBERG V IDEO P ORTAL DCE, 9 pinIf communication cannot be established between the PC/terminal and the TANDBERG Video Portal’s Data port the following should be checked 3. Connecting to the Data port Command Interface using Telnet 4.1.1. Command format 4. The TANDBERG Video Portal CommandsNOTE! The Data port Command Interface is not case sensitive 4.1.2. Command typesXconf telnet mode on 4.2. The commandsXconf telnet mode Command alplan 4.2.1. System Configuration CommandsDialplan Entry 1..64 Enabled On/Off Dialplan Entry 1..64 Name S 0 Dialplan Entry 1..64 ServiceIddistinguished c xConfiguration Dialplan Entry 1 Prefix c xConfiguration Dialplan Entry 2 Property 2 Name avmode c xConfiguration Dialplan Entry 4 Prefix NOTE! The Video Portal needs to reboot before the changes will apply Ethernet H323CallSetup H323GatekeeperH323CallSetup Mode Direct/Gatekeeper H323Gatekeeper Authentication Mode Auto/Off orc xConfiguration H323Gatekeeper Authentication Mode Off Xconf H323Gatekeeper Authenticationc xConfiguration H323Gatekeeper Authentication ID NOTE! Changes become effective after rebootc xConfiguration IP Address Loadlimit Services SessionServices Service 1..64 Enabled On/Off Services Service 1..64 Name S 0 Services Service 1..64 ServiceFile S 0c xConfiguration SIP Mode On SIP Interface Transport Default TCP/UDP/TLSc xConfiguration SIP Interface Server Address c xConfiguration SIP Interface Server Type Autoc xConfiguration SNMP SystemLocation c xConfiguration SNMP SystemContactc xConfiguration SNMP HostIPAddr 1 c xConfiguration SNMP HostIPAddr 2 c xConfiguration SNMP HostIPAddr 3Command ExternalManager NTP Options 4.2.2. General Video Portal Commandsc xConfiguration ExternalManager Address c xConfiguration Options 1 Key 115201SS7-1-55C3EBB7Command Dialplan Disk 4.2.3. System Status CommandsExample DiskEthernet Ethernet ExternalManager Feedback 1MacAddress Speed MacAddress 000E0C5CB57D Speed 100full *s/endH323Gatekeeper H323Gatekeeper IPStatus Address Port Address Port 1719 *s/endNTP Options Address Port Last Update Last CorrectionName Address SubnetMask Gateway 10.31.0.1 DNS ServerService Service SystemLoad SystemUnitOptions SystemLoadConfiguration Telephony VideoTelephony Hardware Version EP Configuration Telephony VideoTelephonyProductType Uptime Software Version Name ReleaseDate PRI TemperatureCelcius TemperatureFahrenheit4.2.5. Special Xcommand Commands 4.2.4. Debug CommandsCommand Syslog Level Mask VolumeDefaultValuesSet Level 1 CheckDisk ClearDialplanEntries ClearServiceEntries DefaultValuesSetExample restore all default factory setting xCommand DefaultValuesSet Parameters Dial DialplanEntryDelete DialplanEntrySwap DisconnectCallOK Result parameter Session ID S 1 Example Parameter DialplanEntryNumber ExampleID 1 ERROR Result parameters OK Result parameters ID 1 ERROR Result parametersEraseDisk FeedbackDeregister FeedbackRegister Expression 1 .. 15 S 0, 256 XPath expression OK Result parametersServiceEntryDelete OptionKeyAdd OptionKeyDelete RestoreDefaultServicesExample Delete Option Key nr. 1 xCommand OptionKeyDelete Parameters ServiceEntryNumberrExample Delete Service nr. 10 xCommand ServiceEntryDelete ServiceEntrySwapParameters ServiceEntryNumberr ServiceEntryNumber2r Example Swap Service nr. 10About Help or ? Licence Relkey Xfeedback General User Commandshelp Licensexhistory ? XhistoryExamples xhistory call