Connections and Wiring

Modes and Front Panel LED Blink Patterns

The following table lists the modes and blink patterns for the front panel LEDs associated with each mode. These patterns are not evident until after the unit is powered.

Modes and LED Blink Patterns

 

 

LEDs and Blink Patterns

 

 

 

 

 

 

 

STATUS

OUTPUT

INPUT

Mode

Description

(green)

(red)

(yellow)

 

 

 

 

 

OS Start

Starting the operating system (OS).

On

On

On

 

 

 

 

 

Boot

On-board Master is booting.

On

Off

On

 

 

 

 

 

Contacting DHCP

On-board Master is contacting a DHCP

On

Off

Fast Blink

server

server for IP configuration information.

 

 

 

 

 

 

 

 

Unknown DHCP

On-board Master could not find the

Fast Blink

Off

Off

server

DHCP server.

 

 

 

 

 

 

 

 

Downloading Boot

Downloading Boot firmware to the

Fast Blink

Fast Blink

Fast Blink

firmware

Master’s on-board flash memory.

 

 

 

 

Do not cycle power during this process!

 

 

 

 

 

 

 

 

No program running

There is no program loaded, or the

On

Normal

Normal

 

program is disabled.

 

 

 

 

 

 

 

 

Normal

On-board Master is functioning normally.

1 blink per second

Indicates

Indicates

 

 

 

activity

activity

 

 

 

 

 

Port Assignments and Functionality

The Port Assignments are as follows:

NI-700 Port Assignments

Port

ICSP Port #

 

 

Serial Port #1

1

 

 

Serial Port #2

2

 

 

IR/Serial Port

3

 

 

I/O Port

4

 

 

IR RX Port

5

 

 

NI-900 Port Assignments

Port

ICSP Port #

 

 

Serial Port #1

1

 

 

IR/Serial Port #1

2

 

 

IR/Serial Port #2

3

 

 

IR/Serial Port #3

4

 

 

I/O Port

5

 

 

IR RX Port

6

 

 

AXlink Port and LED

Both the NI-700 and NI-900 have an AXlink port and adjacent status LED (FIG. 1). This port allows the NI to support AMX Legacy AXlink devices such as G3 touch panels (ex: CP4/A) and PosiTrack Pilot devices. A green LED shows AXlink data activity. When the AXlink port is operating normally, blink patterns include:

Off - No power, or the controller is not functioning properly

1 blink per second - Normal operation.

3 blinks per second - AXlink bus error. Check all AXlink bus connections.

NI-700 & NI-900 Hardware Reference Guide

15

 

 

Image 19
Contents NI-700/900 AMX Limited Warranty and Disclaimer Table of Contents Table of Contents NI-700 & NI-900 Hardware Reference Guide NetLinx Integrated Master Controller Features NI-700 SpecificationsNI-700 Overview See the NI-700 On-Board Memory Specifications section on NI-700 SpecificationsIR RX Rear Panel ComponentsNI-700 Port Assignments NI-700 On-Board Memory SpecificationsNI-700 On-Board Memory Specifications NI-700 Port Assignment And FunctionalityNI-900 Overview NI-900 SpecificationsFront Panel Components NI-900 SpecificationsSurge damage NI-900 Port Assignments NI-900 Port Assignment And FunctionalityRelated Documents NI-900 On-Board Memory SpecificationsNI-900 On-Board Memory Specifications TimeKeeperIntroduction NI-700 & NI-900 Hardware Reference Guide DevicePortSystem DPS Installing into an Equipment RackInstallation Baud Rate Settings on the Configuration DIP Switch Setting the Configuration DIP Switch for the Program PortBaud Rate Settings Program Run Disable PRD ModeProgram Port Connector Pin Signal Program Port Connections and WiringWorking With the Configuration DIP Switch Program Port, Pinouts, and SignalsModes and LED Blink Patterns Modes and Front Panel LED Blink PatternsPort Assignments and Functionality AXlink Port and LEDWiring Guidelines NI-700 @ 280 mA Wiring GuidelinesWiring Length Guidelines Preparing Captive WiresUsing the 4-pin Mini-Phoenix Connector For Data and Power Wiring a Power ConnectionRS-232 RS-422 RS-485 DB9 Device Port Connections and WiringFunction IRX-RX Port Connection and WiringRS-232/422/485 Device Port Wiring Specifications PinPort Wiring Specifications Input/Output I/O Port Connections and WiringPin Signal Function Ethernet RJ-45 Pinouts and Signals IR/Serial Port Connections and WiringEthernet/RJ-45 Port Connections and Wiring IR/Serial Connector Wiring Specifications per PortEthernet LEDs RJ-45 wiring diagramEthernet Port Descriptions Ethernet Ports Used By the Integrated ControllerPort type Description Standard Port # Page Page It’s Your World Take Control

NI-700/900 specifications

The AMX NI-700/900 series represents a significant advancement in the realm of audio-visual management solutions, catering primarily to corporate, educational, and large-scale event environments. Designed for versatility and ease of use, the NI-700 and NI-900 serve as pivotal components in modern audio-visual applications, ensuring seamless integration and superior performance.

The NI-700 features a compact design that is perfect for smaller installations, boasting a powerful processor capable of handling multiple video and audio sources simultaneously. It allows for flexible input configurations, with support for HDMI, VGA, and analog audio, making it compatible with a vast array of devices. The user interface is intuitive, designed for both novice and expert users, with customizable presets that streamline the operation of complex systems.

On the other hand, the NI-900 is engineered for larger environments, where its enhanced processing capabilities truly shine. It supports an extended range of inputs and outputs, including multiple HDMI ports and robust audio distribution options. The NI-900 also features advanced signal processing technology, ensuring high-quality audio and video performance, essential for critical presentations and high-stakes events. Both models incorporate built-in support for networked control, allowing users to manage and monitor their systems remotely.

One of the standout features of the AMX NI-700/900 series is their integration with AMX's extensive software ecosystem. This includes the AMX Rapid Project Maker, which simplifies the programming process, enabling quick deployment and configuration of AV systems. The devices also support various third-party control protocols, ensuring compatibility with existing infrastructure and devices.

Durability and reliability are key attributes of the NI-700 and NI-900. Built with high-quality components, these units are designed for continuous operation in demanding environments. Their foam-filled metal chassis protect against physical damage while maintaining a professional aesthetic.

In summary, the AMX NI-700/900 series epitomizes innovation in AV control technology. With their compact designs, extensive input/output options, advanced processing capabilities, and seamless integration with AMX software, these devices stand out as essential tools for achieving high-performance audio-visual management in diverse settings, ensuring that presentations and events are executed flawlessly.