AMX NI-700/900 manual Wiring Guidelines, Wiring Length Guidelines, Preparing Captive Wires

Page 20

Connections and Wiring

NI-700NI-900

FIG. 1 AXlink connector and LED

The AXlink port can be used to supply power to downstream AXlink-compatible devices as long as both the power required is LESS THAN 2 Amps total and the external power supply feeding the NI unit has the necessary power capability.

Wiring Guidelines

The Integrated Controllers use a 12 VDC-compliant power supply to provide power to the Controller through the rear 2-pin 3.5 mm mini-Phoenix PWR connector. Use the power requirements information described in the product’s Specifications table to determine the power draw.

The incoming PWR and GND cable from the power supply must be connected to the corresponding locations within the PWR connector.

This unit should only have one source of incoming power.

Using more than one source of power to the Controller can result in damage to the internal components and a possible burn out.

Apply power to the unit only after installation is complete.

Wiring Length Guidelines

Refer to the following tables for the wiring length information used with your particular NetLinx Integrated Controller:

Wiring Guidelines - NI-700 @ 280 mA

Wire size

Maximum wiring length

 

 

18 AWG

387.10 feet (117.99 meters)

 

 

20 AWG

245.74 feet (74.90 meters)

 

 

22 AWG

158.50 feet (48.31 meters)

 

 

24 AWG

96.70 feet (29.47 meters)

 

 

Wiring Guidelines - NI-900 @ 300 mA

Wire size

Maximum wiring length

 

 

18 AWG

361.27 feet (110.12 meters)

 

 

20 AWG

229.36 feet (69.91 meters)

 

 

22 AWG

147.93 feet (45.01 meters)

 

 

24 AWG

90.25 feet (27.51 meters)

 

 

Preparing Captive Wires

You will need a wire stripper and flat-blade screwdriver to prepare and connect the captive wires.

Never pre-tin wires for compression-type connections.

1.Strip 0.25 inch (6.35 mm) of insulation off all wires.

2.Insert each wire into the appropriate opening on the connector (according to the wiring diagrams and connector types described in this section).

3.Tighten the screws to secure the wire in the connector. Do not tighten the screws excessively doing so may strip the threads and damage the connector.

16

NI-700 & NI-900 Hardware Reference Guide

Image 20
Contents NI-700/900 AMX Limited Warranty and Disclaimer Table of Contents Table of Contents NI-700 & NI-900 Hardware Reference Guide NI-700 Overview NI-700 SpecificationsNetLinx Integrated Master Controller Features NI-700 Specifications See the NI-700 On-Board Memory Specifications section onRear Panel Components IR RXNI-700 On-Board Memory Specifications NI-700 On-Board Memory SpecificationsNI-700 Port Assignment And Functionality NI-700 Port AssignmentsNI-900 Specifications NI-900 OverviewNI-900 Specifications Front Panel ComponentsSurge damage NI-900 Port Assignment And Functionality NI-900 Port AssignmentsNI-900 On-Board Memory Specifications NI-900 On-Board Memory SpecificationsTimeKeeper Related DocumentsIntroduction NI-700 & NI-900 Hardware Reference Guide Installing into an Equipment Rack DevicePortSystem DPSInstallation Setting the Configuration DIP Switch for the Program Port Baud Rate SettingsProgram Run Disable PRD Mode Baud Rate Settings on the Configuration DIP SwitchProgram Port Connections and Wiring Working With the Configuration DIP SwitchProgram Port, Pinouts, and Signals Program Port Connector Pin SignalModes and Front Panel LED Blink Patterns Port Assignments and FunctionalityAXlink Port and LED Modes and LED Blink PatternsWiring Guidelines Wiring Length GuidelinesPreparing Captive Wires Wiring Guidelines NI-700 @ 280 mAWiring a Power Connection Using the 4-pin Mini-Phoenix Connector For Data and PowerDB9 Device Port Connections and Wiring RS-232 RS-422 RS-485IRX-RX Port Connection and Wiring RS-232/422/485 Device Port Wiring SpecificationsPin FunctionPin Signal Function Input/Output I/O Port Connections and WiringPort Wiring Specifications IR/Serial Port Connections and Wiring Ethernet/RJ-45 Port Connections and WiringIR/Serial Connector Wiring Specifications per Port Ethernet RJ-45 Pinouts and SignalsRJ-45 wiring diagram Ethernet LEDsPort type Description Standard Port # Ethernet Ports Used By the Integrated ControllerEthernet Port Descriptions Page Page It’s Your World Take Control

NI-700/900 specifications

The AMX NI-700/900 series represents a significant advancement in the realm of audio-visual management solutions, catering primarily to corporate, educational, and large-scale event environments. Designed for versatility and ease of use, the NI-700 and NI-900 serve as pivotal components in modern audio-visual applications, ensuring seamless integration and superior performance.

The NI-700 features a compact design that is perfect for smaller installations, boasting a powerful processor capable of handling multiple video and audio sources simultaneously. It allows for flexible input configurations, with support for HDMI, VGA, and analog audio, making it compatible with a vast array of devices. The user interface is intuitive, designed for both novice and expert users, with customizable presets that streamline the operation of complex systems.

On the other hand, the NI-900 is engineered for larger environments, where its enhanced processing capabilities truly shine. It supports an extended range of inputs and outputs, including multiple HDMI ports and robust audio distribution options. The NI-900 also features advanced signal processing technology, ensuring high-quality audio and video performance, essential for critical presentations and high-stakes events. Both models incorporate built-in support for networked control, allowing users to manage and monitor their systems remotely.

One of the standout features of the AMX NI-700/900 series is their integration with AMX's extensive software ecosystem. This includes the AMX Rapid Project Maker, which simplifies the programming process, enabling quick deployment and configuration of AV systems. The devices also support various third-party control protocols, ensuring compatibility with existing infrastructure and devices.

Durability and reliability are key attributes of the NI-700 and NI-900. Built with high-quality components, these units are designed for continuous operation in demanding environments. Their foam-filled metal chassis protect against physical damage while maintaining a professional aesthetic.

In summary, the AMX NI-700/900 series epitomizes innovation in AV control technology. With their compact designs, extensive input/output options, advanced processing capabilities, and seamless integration with AMX software, these devices stand out as essential tools for achieving high-performance audio-visual management in diverse settings, ensuring that presentations and events are executed flawlessly.