AMX NI-700/900 manual Ethernet Ports Used By the Integrated Controller, Ethernet Port Descriptions

Page 27

 

Connections and Wiring

Ethernet Ports Used By the Integrated Controller

 

 

 

 

Ethernet Port Descriptions

 

 

 

 

Port type

Description

Standard Port #

 

 

 

FTP

The on-board Master has a built-in FTP server.

21/20 (TCP)

 

 

 

SSH

The SSH port functions using the same interface as Telnet but over a

22 (TCP)

 

secure shell where it uses SSL as a mechanism to configure and diagnose

 

 

a NetLinx system.

 

 

This port value is used for secure Telnet communication.

 

 

Note: SSH version 2 is only supported.

 

 

 

 

Telnet

The NetLinx Telnet server provides a mechanism to configure and

23 (TCP)

 

diagnose a NetLinx system.

 

 

For maximum flexibility, the Master can be configured to utilize a different

 

 

port than 23, or disable Telnet completely from either Telnet or the

 

 

Program Port located on the rear of the Master itself. Once disabled, the

 

 

only way to enable Telnet again is from the Master’s Program port.

 

 

 

 

HTTP

The Master has a built-in web server that complies with the HTTP 1.0

80 (TCP)

 

specification and supports all of the required features of HTTP v1.1.

 

 

This port is used for unsecure HTTP Internet communication between the

 

 

web browser’s UI and the target Master.

 

 

 

 

HTTPS/SSL

This port is used by a web browser to securely communicate between the

443 (TCP)

 

web server UI and the target Master. This port is also used to

 

 

simultaneously encrypt this data using the SSL certificate information on

 

 

the Master as a key.

 

 

 

 

ICSP

Peer-to-peer protocol used for both Master-to-Master and Master-to-

1319 (UDP/TCP)

 

device communications.

 

 

For maximum flexibility, the Master can be configured to utilize a different

 

 

port than 1319, or disable ICSP over Ethernet completely from either

 

 

Telnet or the Program Port located on the rear of the Master itself.

 

 

This type of communication is used by the various AMX product for

 

 

communication amongst themselves.

 

 

 

 

integration!

This feature on the Master uses, by default, port 10500 for the XML based

10500 (TCP)

Solutions

communication protocol. This port is connected to by the client web

 

 

browser’s JVM when integration! Solutions control pages are retrieved

 

 

from the on-board Master’s web server.

 

 

For maximum flexibility, the on-board Master can be configured to utilize a

 

 

different port than 10500 or to disable integration! Solutions completely.

 

 

 

 

While the NI-700 and NI-900 are capable of receiving 8 and 9 bit characters, they cannot receive 7 bit, 1 stop bit data from a serial device (ex: 9600, N,7,1).

NI-700 & NI-900 Hardware Reference Guide

23

 

 

Image 27
Contents NI-700/900 AMX Limited Warranty and Disclaimer Table of Contents Table of Contents NI-700 & NI-900 Hardware Reference Guide NI-700 Specifications NetLinx Integrated Master Controller FeaturesNI-700 Overview See the NI-700 On-Board Memory Specifications section on NI-700 SpecificationsIR RX Rear Panel ComponentsNI-700 Port Assignments NI-700 On-Board Memory SpecificationsNI-700 On-Board Memory Specifications NI-700 Port Assignment And FunctionalityNI-900 Overview NI-900 SpecificationsFront Panel Components NI-900 SpecificationsSurge damage NI-900 Port Assignments NI-900 Port Assignment And FunctionalityRelated Documents NI-900 On-Board Memory SpecificationsNI-900 On-Board Memory Specifications TimeKeeperIntroduction NI-700 & NI-900 Hardware Reference Guide DevicePortSystem DPS Installing into an Equipment RackInstallation Baud Rate Settings on the Configuration DIP Switch Setting the Configuration DIP Switch for the Program PortBaud Rate Settings Program Run Disable PRD ModeProgram Port Connector Pin Signal Program Port Connections and WiringWorking With the Configuration DIP Switch Program Port, Pinouts, and SignalsModes and LED Blink Patterns Modes and Front Panel LED Blink PatternsPort Assignments and Functionality AXlink Port and LEDWiring Guidelines NI-700 @ 280 mA Wiring GuidelinesWiring Length Guidelines Preparing Captive WiresUsing the 4-pin Mini-Phoenix Connector For Data and Power Wiring a Power ConnectionRS-232 RS-422 RS-485 DB9 Device Port Connections and WiringFunction IRX-RX Port Connection and WiringRS-232/422/485 Device Port Wiring Specifications PinInput/Output I/O Port Connections and Wiring Port Wiring SpecificationsPin Signal Function Ethernet RJ-45 Pinouts and Signals IR/Serial Port Connections and WiringEthernet/RJ-45 Port Connections and Wiring IR/Serial Connector Wiring Specifications per PortEthernet LEDs RJ-45 wiring diagramEthernet Ports Used By the Integrated Controller Ethernet Port DescriptionsPort type Description Standard Port # Page Page It’s Your World Take Control

NI-700/900 specifications

The AMX NI-700/900 series represents a significant advancement in the realm of audio-visual management solutions, catering primarily to corporate, educational, and large-scale event environments. Designed for versatility and ease of use, the NI-700 and NI-900 serve as pivotal components in modern audio-visual applications, ensuring seamless integration and superior performance.

The NI-700 features a compact design that is perfect for smaller installations, boasting a powerful processor capable of handling multiple video and audio sources simultaneously. It allows for flexible input configurations, with support for HDMI, VGA, and analog audio, making it compatible with a vast array of devices. The user interface is intuitive, designed for both novice and expert users, with customizable presets that streamline the operation of complex systems.

On the other hand, the NI-900 is engineered for larger environments, where its enhanced processing capabilities truly shine. It supports an extended range of inputs and outputs, including multiple HDMI ports and robust audio distribution options. The NI-900 also features advanced signal processing technology, ensuring high-quality audio and video performance, essential for critical presentations and high-stakes events. Both models incorporate built-in support for networked control, allowing users to manage and monitor their systems remotely.

One of the standout features of the AMX NI-700/900 series is their integration with AMX's extensive software ecosystem. This includes the AMX Rapid Project Maker, which simplifies the programming process, enabling quick deployment and configuration of AV systems. The devices also support various third-party control protocols, ensuring compatibility with existing infrastructure and devices.

Durability and reliability are key attributes of the NI-700 and NI-900. Built with high-quality components, these units are designed for continuous operation in demanding environments. Their foam-filled metal chassis protect against physical damage while maintaining a professional aesthetic.

In summary, the AMX NI-700/900 series epitomizes innovation in AV control technology. With their compact designs, extensive input/output options, advanced processing capabilities, and seamless integration with AMX software, these devices stand out as essential tools for achieving high-performance audio-visual management in diverse settings, ensuring that presentations and events are executed flawlessly.