AMX AXB-IRS4 Using AXlink for data and power, Using AXlink for data and a 12 VDC power supply

Page 11

Configuration and Installation

Using AXlink for data and power

Connect the Central Controller's AXlink connector to the AXlink/RS-232 connector, on the rear panel of the AXB-IRS4, for data and 12 VDC power, as shown in FIG. 6.

12 VDC PWR connector

PWR (+)

on AXB-IRS4

GND (-)

 

PWR(+)

no connection

PWR

AXlink/RS232 connector

AXP/TX

on AXB-IRS4

AXM/RX

 

GND (-)

FIG. 6 AXlink data and power wiring diagram

AXP

AXM GND

Axcess Control System

Using AXlink for data and a 12 VDC power supply

Connect the Central Controller's AXlink connector to the AXlink/RS-232 connector, on the rear panel of the AXB-IRS4, and the optional 12 VDC power supply, as shown in FIG. 7.

12 VDC PWR connector

PWR (+)

on AXB-IRS4

GND (-)

 

PWR(+)

AXlink/RS232 connector

AXP/TX

on AXB-IRS4

AXM/RX

 

GND (-)

12 VDC power supply

PWR

AXP

AXM

Axcess Control System

 

GND

 

FIG. 7 AXlink and optional 12 VDC power supply wiring diagram

Use the 12 VDC power supply when the distance between the AMX system and AXB-IRS4 exceeds the limits described in the Wiring Guidelines at 125 mA table on page 6. Make sure to connect only the GND wire on the AXlink/RS-232 connector when using a 12 VDC power supply. Do not connect the PWR wire to the AXlink connector's PWR opening.

Using the AXlink-to-DB-9 connector cable for a PC system

To use a PC, set the internal jumpers for RS-232 communication mode and the DEVICE DIP switch positions 1 - 8 off (down).

The AXlink/RS-232 connector, on the back of the AXB-IRS4, can be connected to a PC system using a DB-9 connector cable. Connector pins 2, 3, and 5 are used for data and ground. The following table lists the DB-9 wiring pinouts.

DB-9 Wiring Pinouts

Pin

Signal

Function

Pin

Signal

Function

 

 

 

 

 

 

1

N/A

Not used

6

N/A

Not used

 

 

 

 

 

 

2

RXD

Receive data

7

RTS

Request to send (not used)

 

 

 

 

 

 

3

TXD

Transmit data

8

CTS

Clear to send (not used)

 

 

 

 

 

 

4

DTR

Data terminal ready (not used)

9

N/A

Not used

 

 

 

 

 

 

5

GND

Signal ground

 

 

 

 

 

 

 

 

 

AXB-IRS4 IR/Serial Interface (4 Ports)

7

 

 

 

 

Image 11
Contents AXB-IRS4 AMX Limited Warranty and Disclaimer Table of Contents Table of Contents Front panel components SpecificationsAXB-IRS4 Specifications Product InformationFront and rear views of the AXB-IRS4 Device DIP Switch Settings Configuration and InstallationSetting the Device DIP Switch Setting the Carrier/BAUD DIP switchRS-232 Baud Rate Settings Positions 1-4 Carrier signal enable/disablePosition 5 RS-232/PCTouch mode Positions 6-8 Baud rate settingRS232 communication Removing the circuit cardAXlink communication Preparing/connecting captive wires Wiring the AXB-IRS4Wiring Guidelines Wiring Guidelines at 125 mADB-9 Wiring Pinouts Using AXlink for data and powerUsing AXlink for data and a 12 VDC power supply Using the AXlink-to-DB-9 connector cable for a PC systemDB-25 Wiring Pinouts Using the AXlink-to-DB-25 connector cable for a PC systemSER Serial device wiring diagram Replacing the Lithium BatteryConnecting an IR device Connecting a serial deviceConfiguration and Installation Send Commands Channel Setting CommandsSend Commands Channel Setting CommandsSendcommand 2,CTON,10 Sendcommand 2, CH,18Sendcommand 2,CP,2 Sendcommand 2,CTOF,15Sendcommand IR1, XCH Sendcommand 1,SP,2Sendcommand IR1,XCH RS-232 Protocol Commands IR Output RS-232 Protocol CommandsRS-232 Protocol Commands IR Output RS-232 Protocol Commands Carrier RS-232 Protocol Commands Channel Pulse TimeRS-232 Protocol Commands Channel Pulse Time RS-232 Protocol Commands CarrierZAP!Dev RS-232 Protocol Commands MiscellaneousRS-232 Protocol Commands Miscellaneous ZapallProgramming AXB-IRS4 IR/Serial Interface 4 Ports AMX reserves