AMX AXB-IRS4 RS-232 Protocol Commands Channel Pulse Time, RS-232 Protocol Commands Carrier

Page 19

Programming

RS-232 Protocol Commands (IR Output - Cont.)

 

 

Command

Description

 

 

ON[Dev,Chan]

Start IR output on the designated device and channel.

 

Variable:

 

Dev = 1-4, Chan = 1-252

 

Example:

 

ON[1,11]

 

Starts device 1 and transmits command number 11.

 

 

SP[Dev,Chan]

Transmit single IR code pulse. This command will pulse the actual IR code.

 

Pulse time is set by the CTON and CTOF commands.

 

Variable:

 

Dev = 1-4, Chan = 1-252

 

Example:

 

SP[1,2]

 

Transmits command number 2 pulses to device 1.

 

 

RS-232 Protocol Commands (Channel Pulse Time)

 

 

RS-232 Protocol Commands (Channel Pulse Time)

 

 

Command

Description

 

 

CTOF(Dev,Time)

Set the channel's off-time pulse in tenths of a second. Default time is 5 (0.5

 

second). Time is stored in non-volatile RAM.

 

Variable:

 

Dev = 1-4, Time = 1-255

 

Example:

 

CTOF(1,10)

 

Sets channel off-time pulse to one second on device 1.

 

 

CTON(Dev,Time)

Set the channel's on-time pulse in tenths of a second. Default time is 5 (0.5

 

second). Time is stored in non-volatile RAM.

 

Variable:

 

Dev = 1-4, Time = 1-255

 

Example:

 

CTON(1,10)

 

Sets on-time pulse to 1 second on device 1.

 

 

RS-232 Protocol Commands (Carrier)

RS-232 Protocol Commands (Carrier)

Command

Description

 

 

CAROFF(Dev)

Disable carrier from responding until a CARON command is received. This command

 

overrides the DIP switch setting on the front panel.

 

Variable:

 

Dev = 1-4

 

 

CARON(Dev)

Enable the carrier to respond according to DIP switch settings on the front panel.

 

Variable:

 

Dev = 1-4

 

 

AXB-IRS4 IR/Serial Interface (4 Ports)

15

 

 

 

 

Image 19
Contents AXB-IRS4 AMX Limited Warranty and Disclaimer Table of Contents Table of Contents Front panel components SpecificationsAXB-IRS4 Specifications Product InformationFront and rear views of the AXB-IRS4 Device DIP Switch Settings Configuration and InstallationSetting the Device DIP Switch Setting the Carrier/BAUD DIP switchRS-232 Baud Rate Settings Positions 1-4 Carrier signal enable/disablePosition 5 RS-232/PCTouch mode Positions 6-8 Baud rate settingAXlink communication Removing the circuit cardRS232 communication Preparing/connecting captive wires Wiring the AXB-IRS4Wiring Guidelines Wiring Guidelines at 125 mADB-9 Wiring Pinouts Using AXlink for data and powerUsing AXlink for data and a 12 VDC power supply Using the AXlink-to-DB-9 connector cable for a PC systemDB-25 Wiring Pinouts Using the AXlink-to-DB-25 connector cable for a PC systemSER Serial device wiring diagram Replacing the Lithium BatteryConnecting an IR device Connecting a serial deviceConfiguration and Installation Send Commands Channel Setting CommandsSend Commands Channel Setting CommandsSendcommand 2,CTON,10 Sendcommand 2, CH,18Sendcommand 2,CP,2 Sendcommand 2,CTOF,15Sendcommand IR1,XCH Sendcommand 1,SP,2Sendcommand IR1, XCH RS-232 Protocol Commands IR Output RS-232 Protocol CommandsRS-232 Protocol Commands IR Output RS-232 Protocol Commands Carrier RS-232 Protocol Commands Channel Pulse TimeRS-232 Protocol Commands Channel Pulse Time RS-232 Protocol Commands CarrierZAP!Dev RS-232 Protocol Commands MiscellaneousRS-232 Protocol Commands Miscellaneous ZapallProgramming AXB-IRS4 IR/Serial Interface 4 Ports AMX reserves