AMX AXB-TM5 Connection and Wiring, Device DIP Switch, Device DIP switch settings, Position Value

Page 7

Connection and Wiring

Connection and Wiring

Device DIP Switch

The eight-position Device DIP switch, shown in FIG. 2, sets the AXlink device number. Every device on the bus must have a unique device code. An eight-position DIP switch is used to set the device number for the AXB-TM5. The device number must match the number assigned in the Axcess software program. The AXlink device number range is 1-255 and is sent according to the Device DIP switch positions and their values.

After setting the AXlink device number, remove and reconnect the AXlink connector on the AXB-TM5 to store the new number into memory.

As an example, FIG. 2 is set to 85 (1 + 4 + 16 + 64 = 85), which is the factory default setting.

FIG. 2 Device Code DIP switch setting example

The following table describes the Device Code DIP switch settings and its corresponding DIP switch arrangements.

Device DIP switch settings

Position

1

2

3

4

5

6

7

8

 

 

 

 

 

 

 

 

 

Value

1

2

4

8

16

32

64

128

 

 

 

 

 

 

 

 

 

The device number takes effect only on power-up. If you later change the device number, remove and reconnect the AXlink connector. This enters the new device number into memory.

AMX standard device numbers are assigned as follows:

!Cards are 1 through 25.

!Boxes are 96 through 127.

!Panels are 128 through 255.

AXB-TM5 Television Manager

3

 

 

 

 

Image 7
Contents AXB-TM5 AMX Limited Warranty and Disclaimer Table of Contents Table of Contents Front Panel SpecificationsSpecifications Product InformationRear Panel Components Front Panel ComponentsPosition Value Connection and WiringDevice DIP Switch Device DIP switch settingsWiring Guidelines @ 200 mA Wiring the Rear PanelPreparing/connecting captive wires Wiring GuidelinesIR emitter to device installation CC-IRC emitter wiring connectionsTV sensor connections AXlink data and 12 VDC power supply connectionsPCS connections IRX-SM connections AXlink 12 VDC power supply wiring exampleConnection and Wiring Device Assignment Channel Setting CommandsAXB-TM5 Channel Settings ProgrammingSystem SendCommands System SendCommandsSendcommand AXBTMX,DE,10 Sendcommand AXBTMX,CTON,20Sendcommand AXBTMX,?CTON Sendcommand AXBTMX,DC,145,24Sendcommand AXBTMX,PIN Sendcommand AXBTMX,?DESendcommand AXBTMX,DK Sendcommand AXBTMX,PIFSendcommand AXBTMX,?PTON Sendcommand AXBTMX,PTOF,15Sendcommand AXBTMX,?PTOF Sendcommand AXBTMX,PTON,20RO,offset Sendcommand AXBTMX,RO,5Sendcommand AXBTMX,SP,25 Sendcommand DEV,XCH ChannelXchm Sendcommand DEV,XCH-ModeSendcommand AXBTMX,XCH Sendcommand IR1, XCHAMX reserves