Programming
Programming
You can program the
Channel Setting Commands
The
AXB-TM5 Channel Settings
Channel | Function |
|
|
1 | Generates IR/Serial functions 1, else Off |
|
|
2 - 127 | Channels the generate IR code for the corresponding functions |
|
|
128 - 247 | Push and release channels for received IR code |
|
|
248 | A push on this channel indicates a power failure error |
|
|
249 | Response LED blinks when channels 249 and 250 are On |
|
|
250 | Response LED lights when channel is On |
|
|
251 | I/O is On (switch to GND) when channel is On |
|
|
252 | I/O 2 is On (switch to GND) when channel is On |
|
|
253 | I/O 3 is On (switch to GND) when channel is On |
|
|
254 | I/O 4 is On (switch to GND) when channel is On |
|
|
255 | Channel is On if the TV Power Sensor detects a horizontal scan frequency |
|
|
Turning a channel (IR/Serial function) on while another one is currently on will automatically turn the current one off first. Contact closure inputs on I/O 1 through I/O 4 will also generate PUSHes and RELEASEs on channels 251 through 254, respectively.
Device Assignment
The device assignment must be the same as the device number set on the Device DIP switches
(FIG. 2 on page 3).
9 |
| |
|
|
|