AMX AXB-TM5 Wiring the Rear Panel, Preparing/connecting captive wires, Wiring Guidelines

Page 8

Connection and Wiring

Wiring the Rear Panel

Preparing/connecting captive wires

You will need a wire stripper and flat-blade screwdriver to prepare and connect the captive wires.

Never pre-tin wires for compression-type connections.

Do not connect power to the AXB-TM5 until the wiring is complete. If you are using power from AXlink, disconnect the wiring from the control system before wiring the AXB-TM5. If you are using an optional 12 VDC power supply, apply power to the AXB-TM5 only after installation is complete.

1.Strip 0.25 inch of wire insulation off all wires.

2.Insert each wire into the appropriate opening on the connector according to the wiring diagrams and connector types described in this section.

3.Do not tighten the screws excessively; doing so may strip the threads and damage the connector.

Wiring Guidelines

The AXB-TM5 requires 12 VDC power to operate properly. The power can be supplied by the AMX system's AXlink cable or with an optional 12 VDC power supply. The maximum wiring distance between the control system and AXB-TM5 is determined by power consumption, supplied voltage, and the wire gauge used for the cable. The following table lists wire sizes and the maximum lengths allowable between the AXB-TM5 and the control system. The maximum wiring lengths are based on a minimum of 13.5 volts available at the control system's power supply.

Wiring Guidelines @ 200 mA

Wire size

Maximum wiring length

 

 

18 AWG

586.55 feet (178.78 meters)

 

 

20 AWG

371.29 feet (113.17 meters)

 

 

22 AWG

231.48 feet (70.56 meters)

 

 

24 AWG

145.91 feet (44.47 meters)

 

 

If the AXB-TM5 is installed farther away from the control system than recommended in the above table, connect an external 12 VDC power supply to the two-pin PWR connector on the rear panel.

Using the AXlink connector for data and power

To use the AXlink 4-pin connector for data communication and for power supply, the incoming PWR and GND cable from the control system must be connected to the AXlink cable connector going to the control system as sown in the AXlink wiring diagram (FIG. 3).

PWR +

 

 

 

 

 

 

 

 

 

 

PWR +

 

 

 

 

 

 

 

 

 

 

AXP/TX

 

 

 

 

 

 

 

 

 

 

AXP/TX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AXM/RX

 

 

 

 

 

 

 

 

 

 

AXM/RX

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND -

 

 

 

 

 

 

 

 

 

 

GND -

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

To the AXB-TM5

To the Control system

FIG. 3 AXlink connector wiring diagram

 

 

 

 

 

 

 

4

AXB-TM5 Television Manager

 

 

 

Image 8
Contents AXB-TM5 AMX Limited Warranty and Disclaimer Table of Contents Table of Contents Specifications SpecificationsProduct Information Front PanelFront Panel Components Rear Panel ComponentsConnection and Wiring Device DIP SwitchDevice DIP switch settings Position ValueWiring the Rear Panel Preparing/connecting captive wiresWiring Guidelines Wiring Guidelines @ 200 mACC-IRC emitter wiring connections IR emitter to device installationPCS connections AXlink data and 12 VDC power supply connectionsTV sensor connections AXlink 12 VDC power supply wiring example IRX-SM connectionsConnection and Wiring Channel Setting Commands AXB-TM5 Channel SettingsProgramming Device AssignmentSystem SendCommands System SendCommandsSendcommand AXBTMX,CTON,20 Sendcommand AXBTMX,?CTONSendcommand AXBTMX,DC,145,24 Sendcommand AXBTMX,DE,10Sendcommand AXBTMX,?DE Sendcommand AXBTMX,DKSendcommand AXBTMX,PIF Sendcommand AXBTMX,PINSendcommand AXBTMX,PTOF,15 Sendcommand AXBTMX,?PTOFSendcommand AXBTMX,PTON,20 Sendcommand AXBTMX,?PTONSendcommand AXBTMX,RO,5 Sendcommand AXBTMX,SP,25Sendcommand DEV,XCH Channel RO,offsetSendcommand DEV,XCH-Mode Sendcommand AXBTMX,XCHSendcommand IR1, XCH XchmAMX reserves