AMX NXC-ME260 Route Mode, Directnormal, Sendcommand DPS, Sendstring DPS, Set Dns Dps, Set Ip Dps

Page 23

Programming

Program Port Commands (Cont.)

Command

Description

 

 

 

 

ROUTE MODE

Sets the Master-to-Master route mode:

DIRECTNORMAL

• Normal mode - allows a Master to communicate with any Master

 

accessible via the routing tables (shown with the SHOW ROUTE

 

command). This includes a directly-connected Master (route metric =1)

 

and indirectly connected masters (route metric greater than 1, but less

 

than 16).

 

 

 

• Direct mode - allows communication only with masters that are directly

 

connected (route metric = 1). Indirectly connected masters cannot be

 

communicated within this mode.

 

Examples:

 

 

 

>ROUTE MODE DIRECT

 

 

 

Route Mode "Direct" Set

 

 

>ROUTE MODE NORMAL

 

 

 

Route Mode "Normal" Set

 

 

 

SEND_COMMAND <D:P:S>

Sends a command to a device. The device can be on any system the Mas-

 

ter you are connected to can reach. You can specify the device number,

 

port, and system; or the name of the device that is defined in the

 

DEFINE_DEVICE section of the NetLinx Program. The data of the string is

 

entered with NetLinx string syntax.

 

 

SEND_STRING <D:P:S>

Sends a string to a device. The device can be on any system the Master

 

you are connected to can reach. You can specify the device number, port,

 

and system; or the name of the device defined in the DEFINE_DEVICE

 

section of the NetLinx Program. The data of the string is entered with

 

NetLinx string syntax.

 

 

 

 

SET DNS <D:P:S>

Prompts you to enter a Domain Name, DNS IP #1, DNS IP #2, and DNS IP

 

#3. Then, enter Y (yes) to approve/store the information in the Master

 

Card. Entering N (no) cancels the operation.

 

Example:

 

 

 

>SET DNS [0:1:0]

 

 

 

-- Enter New Values or just hit Enter to keep current settings --

 

Enter Domain Suffix: amx.com

 

Enter DNS Entry 1

: 192.168.20.5

 

Enter DNS Entry 2

: 12.18.110.8

 

Enter DNS Entry 3

: 12.18.110.7

 

You have entered: Domain Name: amx.com

 

 

DNS Entry 1: 192.168.20.5

 

 

DNS Entry 2: 12.18.110.8

 

 

DNS Entry 3: 12.18.110.7

 

Is this correct? Type Y or N and Enter -> Y

 

Settings written. Device must be rebooted to enable new settings

 

 

SET IP <D:P:S>

Prompts you to enter a Host Name, Type (DHCP or Fixed), IP address,

 

Subnet Mask, and Gateway IP address.

 

Enter Y (yes) to approve/store the information in the Master Card.

 

Entering N (no) cancels the operation.

 

Example:

 

 

 

>SET IP [0:1:0]

 

 

 

--- Enter New Values or just hit Enter to keep current settings ---

 

Enter Host Name:

MLK_INSTRUCTOR

 

Enter IP type. Type D for DHCP or S for Static IP and then Enter: DHCP

 

Enter Gateway IP:

192.168.21.2

 

You have entered: Host Name

MLK_INSTRUCTOR

 

Type

DHCP

 

Gateway IP

192.168.21.2

 

Is this correct? Type Y or N and Enter -> y

 

Settings written. Device must be rebooted to enable new settings.

 

 

 

 

NXC-ME260 NetLinx Master-Ethernet Card/Module

19

 

 

 

 

Image 23
Contents NXC-ME260 AMX Limited Warranty and Disclaimer Table of Contents Main Security Menu Default Security Configuration Input LED yellow Output LED red Status LED green Product InformationFront and rear panel components NXM-ME260 Specifications SpecificationsEthernet Ports Used by the ME260 Ethernet ports used by the ME260Rear panel LEDs ICSNet/ICSHub Modes and front panel LED blink patternsModes and LED Blink Patterns Layout of Ethernet LEDs Rear panel LEDs EthernetProduct Information Program Run Disable PRD mode Installation and WiringSetting the Program Port DIP Switch Baud rate settingsDB-9 Program Port, Pinouts, and Signals Program Port Connections/WiringSetting the Program Port DIP switch Preparing/connecting captive wiresICSNet RJ-45 Pinouts/Signals ICSNet RJ-45 Connections/WiringICSHub RJ-45 Connections/Wiring Pin Program Port Pinouts and SignalsICSHub OUT port Ethernet 10/100 Base-T RJ-45 Connections/WiringICSHub in port Expansion in port RJ-11 SPE Port Connection/WiringRJ-45 Plug RJ-45 wiring diagram SPE cable pinout information SPE Connector Pinouts and SignalsExpansion OUT connector on rear of NXC-ME260 TX enable No connectMaster Card slot on NXF CardFrame rear panel RJ-11 Plug RJ-11 wiring diagramMounting the Modules Into an Equipment Rack Mounting the NXC-ME260 in an NXF CardFrame or NXIReplacing the Lithium Batteries Battery CR2032 type 20mm coin cell SocketProgramming Program Port CommandsPC COM Port Communication Settings Program Port CommandsDevice Status DPS SET DateTime SET TimeMEM Disk FreeGET IP DPS Program Info Reboot DPSPass DPS Ping IP AddressSendstring DPS Route ModeSendcommand DPS DirectnormalDisplays a list of any combined devices Example SET URL DPSShow Combine Show Device DPSShow Notify Show LOGShow System Show RemoteShow Route URL List DPS ESC Pass CodesESC Pass Codes TCP ListLinux Telnet client Windows client programsSending Firmware to a NetLinx Device KIT file Firmware TransfersFirmware Transfers User NetLinx Security FeaturesNetLinx Security Security Terms Used in This DocumentGroup Name PasswordAccess Rights User NameCont Initial Setup via Telnet or Terminal ConnectionAccessing the Security configuration options Getting connectedMaster must be rebooted after changing the Http setting Display system security options for NetLinx Master Security Options MenuEdit User Menu Add userEdit User Edit User Menu Access Rights MenuAdd Group Access Rights MenuDelete user Show the list of authorized usersSubdirectories in the user directory Enables access to the user directory and all filesEdit Group Menu Edit Group Menu Add directory associationEdit Group menu List directory associations Edit Group menu Change Access RightsEdit Group menu Delete directory association Delete Group Edit Group menu Display Access RightsEdit Group Make changes permanent by saving to flash Set Telnet Timeout in secondsDisplay Telnet Timeout in seconds Show List of Authorized GroupsMain Security Menu Main Security MenuDefault Security Configuration Help Menu Options Help menuLogging Into a Session Help Security Setup SecurityLogout AMX reserves
Related manuals
Manual 106 pages 58.54 Kb

NXC-ME260 specifications

The AMX NXC-ME260 is a cutting-edge piece of machinery designed to meet the demands of modern industrial environments. This equipment stands out due to its superior performance, enhanced efficiency, and innovative technologies, making it suitable for a wide range of applications.

One of the primary features of the NXC-ME260 is its robust design. Built with high-quality materials, this machine is engineered to withstand rigorous operating conditions, ensuring durability and longevity. The compact structure allows it to fit seamlessly into various workspaces, making it an ideal choice for operations with limited space.

Equipped with a powerful motor, the NXC-ME260 delivers exceptional speed and torque. This enables it to handle demanding tasks with ease, resulting in increased productivity. The machine’s advanced control system ensures precise operation, making it user-friendly and efficient. Its intuitive interface allows operators to quickly adapt to its functionalities, minimizing training time and boosting operational efficiency.

The NXC-ME260 integrates state-of-the-art technologies that enhance its performance. One of the standout features is its energy-efficient design, which reduces power consumption without compromising output. This makes the machine not only cost-effective but also an environmentally responsible choice for companies looking to reduce their carbon footprint.

Another significant technology incorporated in the NXC-ME260 is its intelligent monitoring system. This system provides real-time data on machine performance, allowing operators to make informed decisions and perform proactive maintenance. By predicting potential issues before they arise, the NXC-ME260 minimizes downtime and maintenance costs, ensuring uninterrupted operations.

Safety is paramount in any industrial setting, and the NXC-ME260 excels in this regard. It is equipped with multiple safety features, including emergency stop mechanisms and overload protection, ensuring operator safety and reducing the risk of accidents.

In summary, the AMX NXC-ME260 represents a convergence of power, efficiency, and safety-focused design. Its robust construction, advanced motor performance, intelligent monitoring system, and energy-efficient operation make it an invaluable asset for any industrial operation. Whether in manufacturing, logistics, or other sectors, the NXC-ME260 is engineered to enhance productivity while ensuring a safe working environment. Overall, this machine exemplifies the future of industrial equipment, bringing together technology and efficiency for optimal performance.