AMX NXC-ME260 instruction manual Show Remote, Show Route, Show System

Page 26

Programming

Program Port Commands (Cont.)

Command

Description

 

 

 

 

 

 

 

SHOW REMOTE

Displays a list of the devices this system requires input from and the types

 

of information needed. If when a NetLinx Master connects to another

 

NetLinx Master, the newly connecting system has a device that the local

 

system desires input from; the new system is told what information is

 

desired from what device.

 

 

 

 

Example:

 

 

 

 

 

 

 

>SHOW REMOTE

 

 

 

 

 

Device List of Remote Devices requested by this System

 

Device

Port

System

Needs

 

 

 

------------------------------------------------------

 

00001

00001

00001

Channels Commands

 

 

 

00002

00001

00001

Channels Commands

 

 

 

33000

00001

00001

Channels Commands

 

 

 

00128

00001

00108

Channels Commands Strings Levels

 

33000

00001

00108

Channels Commands

 

 

 

 

SHOW ROUTE

Displays information about how this NetLinx Master is connected to other

 

NetLinx masters.

 

 

 

 

 

Example:

 

 

 

 

 

 

 

 

>SHOW ROUTE

 

 

 

 

 

 

Route Data:

 

 

 

 

 

System Route

Metric

PhyAddress

 

 

 

--------------------------------

 

 

 

-> 50

50

0

Axlink

 

 

 

 

SHOW SYSTEM

Provides a list of all devices in all systems currently on-line. The systems

 

lists are either directly connected to this Master (i.e. 1 hop away), or are

 

referenced in the DEFINE_DEVICE section of the NetLinx program.

 

Optionally, you may provide the desired system number as a parameter to

 

display only that system's information (e.g. SHOW SYSTEM 2001). The

 

systems listed are in numerical order.

 

 

 

Example:

 

 

 

 

 

 

 

>SHOW SYSTEM

 

 

 

 

 

 

Local devices for system #50 (This System)

 

 

 

------------------------------------------------------------

 

 

Device (ID)Model

 

(ID)Mfg

FWID

Version

 

00000

 

(00256)Master

(00001)AMX Corp.

00256

v2.10.75

 

 

(PID=0:OID=0) Serial='2010-12090',0,0,0,0,0,0

 

 

 

 

Physical Address=NeuronID 000239712501

 

 

 

 

 

(00256)vxWorks Image

(00001)

00257

v2.00.77

 

 

 

(PID=0:OID=1) Serial=N/A

 

 

 

 

 

(00256)BootROM

(00001)

00258

v2.00.76

 

 

 

(PID=0:OID=2) Serial=N/A

 

 

 

 

 

(00256)AXLink I/F uContr(00001)

00270

v1.02

 

 

 

(PID=0:OID=3) Serial=0000000000000000

 

 

 

00096

(00192)VOLUME 3 CONTROL BO(00001)AMX Corp.

00000

v2.10

 

 

(PID=0:OID=0) Serial=0000000000000000

 

 

 

 

Physical Address=Axlink

 

 

 

00128

(00188)COLOR LCD TOUCH PAN(00001)AMX Corp.

32778

v5.01d

 

 

(PID=0:OID=0) Serial=0000000000000000

 

 

 

 

Physical Address=Axlink

 

 

 

05001

 

(00257)NXI Download

(00001)AMX Corp.

00260

v1.00.20

 

 

(PID=0:OID=0) Serial=0,0,0,0,0,0,0,0,0,0,0,0,

 

 

 

 

Physical Address=NeuronID 000189145801

 

 

 

 

 

(00257)NXI/NXI-1000 Boot(00001)

00261

v1.00.00

 

 

 

(PID=0:OID=1) Serial=0,0,0,0,0,0,0,0,0,0,0,0,

 

 

 

10002

 

(00003)PHAST PLK-IMS

(00001)Phast Corp.

0003

v3.12

 

 

(PID=0:OID=0) Serial=0000000000000000

 

 

 

 

Physical Address=NeuronID 0100417BD800

 

 

 

 

 

 

 

 

 

 

 

 

22

NXC-ME260 NetLinx Master-Ethernet Card/Module

 

 

 

Image 26
Contents NXC-ME260 AMX Limited Warranty and Disclaimer Table of Contents Main Security Menu Default Security Configuration Input LED yellow Output LED red Status LED green Product InformationFront and rear panel components Specifications NXM-ME260 SpecificationsEthernet ports used by the ME260 Ethernet Ports Used by the ME260Rear panel LEDs ICSNet/ICSHub Modes and front panel LED blink patternsModes and LED Blink Patterns Rear panel LEDs Ethernet Layout of Ethernet LEDsProduct Information Baud rate settings Installation and WiringSetting the Program Port DIP Switch Program Run Disable PRD modePreparing/connecting captive wires Program Port Connections/WiringSetting the Program Port DIP switch DB-9 Program Port, Pinouts, and SignalsPin Program Port Pinouts and Signals ICSNet RJ-45 Connections/WiringICSHub RJ-45 Connections/Wiring ICSNet RJ-45 Pinouts/SignalsICSHub OUT port Ethernet 10/100 Base-T RJ-45 Connections/WiringICSHub in port Expansion in port RJ-11 SPE Port Connection/WiringRJ-45 Plug RJ-45 wiring diagram TX enable No connect SPE Connector Pinouts and SignalsExpansion OUT connector on rear of NXC-ME260 SPE cable pinout informationMounting the NXC-ME260 in an NXF CardFrame or NXI RJ-11 Plug RJ-11 wiring diagramMounting the Modules Into an Equipment Rack Master Card slot on NXF CardFrame rear panelBattery CR2032 type 20mm coin cell Socket Replacing the Lithium BatteriesProgram Port Commands Program Port CommandsPC COM Port Communication Settings ProgrammingSET Time SET DateTime Device Status DPSMEM Disk FreeGET IP DPS Ping IP Address Reboot DPSPass DPS Program InfoDirectnormal Route ModeSendcommand DPS Sendstring DPSShow Device DPS SET URL DPSShow Combine Displays a list of any combined devices ExampleShow LOG Show NotifyShow System Show RemoteShow Route TCP List ESC Pass CodesESC Pass Codes URL List DPSWindows client programs Linux Telnet clientFirmware Transfers Sending Firmware to a NetLinx Device KIT fileFirmware Transfers Security Terms Used in This Document NetLinx Security FeaturesNetLinx Security UserUser Name PasswordAccess Rights Group NameGetting connected Initial Setup via Telnet or Terminal ConnectionAccessing the Security configuration options ContMaster must be rebooted after changing the Http setting Security Options Menu Display system security options for NetLinx MasterEdit User Menu Add userEdit User Access Rights Menu Edit User MenuShow the list of authorized users Access Rights MenuDelete user Add GroupEdit Group Menu Add directory association Enables access to the user directory and all filesEdit Group Menu Subdirectories in the user directoryEdit Group menu List directory associations Edit Group menu Change Access RightsEdit Group menu Delete directory association Delete Group Edit Group menu Display Access RightsEdit Group Show List of Authorized Groups Set Telnet Timeout in secondsDisplay Telnet Timeout in seconds Make changes permanent by saving to flashMain Security Menu Main Security MenuDefault Security Configuration Help menu Help Menu OptionsLogging Into a Session Help Security Setup SecurityLogout AMX reserves
Related manuals
Manual 106 pages 58.54 Kb

NXC-ME260 specifications

The AMX NXC-ME260 is a cutting-edge piece of machinery designed to meet the demands of modern industrial environments. This equipment stands out due to its superior performance, enhanced efficiency, and innovative technologies, making it suitable for a wide range of applications.

One of the primary features of the NXC-ME260 is its robust design. Built with high-quality materials, this machine is engineered to withstand rigorous operating conditions, ensuring durability and longevity. The compact structure allows it to fit seamlessly into various workspaces, making it an ideal choice for operations with limited space.

Equipped with a powerful motor, the NXC-ME260 delivers exceptional speed and torque. This enables it to handle demanding tasks with ease, resulting in increased productivity. The machine’s advanced control system ensures precise operation, making it user-friendly and efficient. Its intuitive interface allows operators to quickly adapt to its functionalities, minimizing training time and boosting operational efficiency.

The NXC-ME260 integrates state-of-the-art technologies that enhance its performance. One of the standout features is its energy-efficient design, which reduces power consumption without compromising output. This makes the machine not only cost-effective but also an environmentally responsible choice for companies looking to reduce their carbon footprint.

Another significant technology incorporated in the NXC-ME260 is its intelligent monitoring system. This system provides real-time data on machine performance, allowing operators to make informed decisions and perform proactive maintenance. By predicting potential issues before they arise, the NXC-ME260 minimizes downtime and maintenance costs, ensuring uninterrupted operations.

Safety is paramount in any industrial setting, and the NXC-ME260 excels in this regard. It is equipped with multiple safety features, including emergency stop mechanisms and overload protection, ensuring operator safety and reducing the risk of accidents.

In summary, the AMX NXC-ME260 represents a convergence of power, efficiency, and safety-focused design. Its robust construction, advanced motor performance, intelligent monitoring system, and energy-efficient operation make it an invaluable asset for any industrial operation. Whether in manufacturing, logistics, or other sectors, the NXC-ME260 is engineered to enhance productivity while ensuring a safe working environment. Overall, this machine exemplifies the future of industrial equipment, bringing together technology and efficiency for optimal performance.