AMX NXC-ME260 instruction manual NXM-ME260 Specifications

Page 6

Product Information

Specifications

NXM-ME260 Specifications

Power consumption

750 mA @ 12 VDC

 

 

Memory

• Compact Flash: 16 MB standard (upgradeable)

 

• Volatile: 16 MB

 

Non-volatile: 1 MB

 

 

Microprocessor

Coldfire 5407 (32-bit )

 

 

Front Panel Components:

 

Program port

DB-9 (male) connector that supports RS-232 communications to your PC for

 

system programming and diagnostics. You set the port's communication speed

 

with the Baud Rate DIP switch. See the Setting the Program Port DIP

 

Switch section on page 7 for details.

 

There are Program ports located on the front and rear panels of the Master

 

Card for easy access. Because these ports share the same circuitry, you

 

should never use both at the same time; doing so will result in communication

 

and/or programming errors.

 

 

Status LED

Green LED blinks to indicate that the system is programmed and communicat-

 

ing properly.

 

 

Output LED

Red LED blinks when the Master Card transmits data, sets channels on and

 

off, sends data strings, etc.

 

 

Input LED

Yellow LED blinks when the Master Card receives data from button pushes,

 

strings, commands, channel levels, etc.

 

 

Front Panel LEDs -

These LEDs also display special blink patterns when a mode is activated. See

blink patterns

the Modes and front panel LED blink patterns section on page 4 for details.

 

 

Program Port DIP Switch

8-position DIP switch located behind the front panel for setting the baud rate for

 

the Program port. The baud rate settings are 9600, 38,400 (default), 57,600

 

and 115,200 (bps). See the Setting the Program Port DIP Switch section on

 

page 7 for details.

 

 

Rear Panel Components:

 

PWR connector

2-pin (male) green captive-wire connector for 12 VDC power supply.

 

 

EXPANSION OUT port

RJ11 connector connects to an AXB-SPE Server Port Expander.

 

 

Ethernet 10/100 port

RJ-45 Ethernet 10/100 connector. The Ethernet Port automatically negotiates

 

the connection speed (10 Mbps or 100 Mbps) and whether to use half duplex

 

or full duplex mode.

 

 

Ethernet 10/100 LEDs

LEDs that show communication activity, connections, speeds, and mode infor-

 

mation:

 

A-activity - Yellow LED blinks when receiving Ethernet data packets.

 

L-link - Green LED lights when the Ethernet cables are connected and

 

terminated correctly.

 

• SPEED - Green LED lights when transmitting data at 100 Mbps, and is off

 

when transmitting at 10 Mbps.

 

FD-full duplex - Green LED lights when running in full duplex mode, and is off

 

when running half duplex mode.

 

 

AXlink connector

Black 4-pin (male) captive-wire connector that provides data and power to

 

external control devices.

 

• Power rating = 6 A max; actual load depends on connected power supply.

 

 

Axlink Status LED

Green LED blinks to show AXlink and expansion port data activity.

 

 

PROGRAM port

5-pin (male) gray connector for system programming and diagnostics. There is

 

a Program port located on the front and rear of the Master Cards for easy

 

access. Because these ports share the same circuitry, you should never use

 

both ports at the same time. Doing so will result in communication and/or pro-

 

gramming errors.

 

 

 

2

NXC-ME260 NetLinx Master-Ethernet Card/Module

 

 

 

Image 6
Contents NXC-ME260 AMX Limited Warranty and Disclaimer Table of Contents Main Security Menu Default Security Configuration Product Information Front and rear panel componentsInput LED yellow Output LED red Status LED green Specifications NXM-ME260 SpecificationsEthernet ports used by the ME260 Ethernet Ports Used by the ME260Modes and front panel LED blink patterns Modes and LED Blink PatternsRear panel LEDs ICSNet/ICSHub Rear panel LEDs Ethernet Layout of Ethernet LEDsProduct Information Baud rate settings Installation and WiringSetting the Program Port DIP Switch Program Run Disable PRD modePreparing/connecting captive wires Program Port Connections/WiringSetting the Program Port DIP switch DB-9 Program Port, Pinouts, and SignalsPin Program Port Pinouts and Signals ICSNet RJ-45 Connections/WiringICSHub RJ-45 Connections/Wiring ICSNet RJ-45 Pinouts/SignalsEthernet 10/100 Base-T RJ-45 Connections/Wiring ICSHub in portICSHub OUT port SPE Port Connection/Wiring RJ-45 Plug RJ-45 wiring diagramExpansion in port RJ-11 TX enable No connect SPE Connector Pinouts and SignalsExpansion OUT connector on rear of NXC-ME260 SPE cable pinout informationMounting the NXC-ME260 in an NXF CardFrame or NXI RJ-11 Plug RJ-11 wiring diagramMounting the Modules Into an Equipment Rack Master Card slot on NXF CardFrame rear panelBattery CR2032 type 20mm coin cell Socket Replacing the Lithium BatteriesProgram Port Commands Program Port CommandsPC COM Port Communication Settings ProgrammingSET Time SET DateTime Device Status DPSDisk Free GET IP DPSMEM Ping IP Address Reboot DPSPass DPS Program InfoDirectnormal Route ModeSendcommand DPS Sendstring DPSShow Device DPS SET URL DPSShow Combine Displays a list of any combined devices ExampleShow LOG Show NotifyShow Remote Show RouteShow System TCP List ESC Pass CodesESC Pass Codes URL List DPSWindows client programs Linux Telnet clientFirmware Transfers Sending Firmware to a NetLinx Device KIT fileFirmware Transfers Security Terms Used in This Document NetLinx Security FeaturesNetLinx Security UserUser Name PasswordAccess Rights Group NameGetting connected Initial Setup via Telnet or Terminal ConnectionAccessing the Security configuration options ContMaster must be rebooted after changing the Http setting Security Options Menu Display system security options for NetLinx MasterAdd user Edit UserEdit User Menu Access Rights Menu Edit User MenuShow the list of authorized users Access Rights MenuDelete user Add GroupEdit Group Menu Add directory association Enables access to the user directory and all filesEdit Group Menu Subdirectories in the user directoryEdit Group menu Change Access Rights Edit Group menu Delete directory associationEdit Group menu List directory associations Edit Group menu Display Access Rights Edit GroupDelete Group Show List of Authorized Groups Set Telnet Timeout in secondsDisplay Telnet Timeout in seconds Make changes permanent by saving to flashMain Security Menu Main Security MenuDefault Security Configuration Help menu Help Menu OptionsLogging Into a Session Setup Security LogoutHelp Security AMX reserves
Related manuals
Manual 106 pages 58.54 Kb

NXC-ME260 specifications

The AMX NXC-ME260 is a cutting-edge piece of machinery designed to meet the demands of modern industrial environments. This equipment stands out due to its superior performance, enhanced efficiency, and innovative technologies, making it suitable for a wide range of applications.

One of the primary features of the NXC-ME260 is its robust design. Built with high-quality materials, this machine is engineered to withstand rigorous operating conditions, ensuring durability and longevity. The compact structure allows it to fit seamlessly into various workspaces, making it an ideal choice for operations with limited space.

Equipped with a powerful motor, the NXC-ME260 delivers exceptional speed and torque. This enables it to handle demanding tasks with ease, resulting in increased productivity. The machine’s advanced control system ensures precise operation, making it user-friendly and efficient. Its intuitive interface allows operators to quickly adapt to its functionalities, minimizing training time and boosting operational efficiency.

The NXC-ME260 integrates state-of-the-art technologies that enhance its performance. One of the standout features is its energy-efficient design, which reduces power consumption without compromising output. This makes the machine not only cost-effective but also an environmentally responsible choice for companies looking to reduce their carbon footprint.

Another significant technology incorporated in the NXC-ME260 is its intelligent monitoring system. This system provides real-time data on machine performance, allowing operators to make informed decisions and perform proactive maintenance. By predicting potential issues before they arise, the NXC-ME260 minimizes downtime and maintenance costs, ensuring uninterrupted operations.

Safety is paramount in any industrial setting, and the NXC-ME260 excels in this regard. It is equipped with multiple safety features, including emergency stop mechanisms and overload protection, ensuring operator safety and reducing the risk of accidents.

In summary, the AMX NXC-ME260 represents a convergence of power, efficiency, and safety-focused design. Its robust construction, advanced motor performance, intelligent monitoring system, and energy-efficient operation make it an invaluable asset for any industrial operation. Whether in manufacturing, logistics, or other sectors, the NXC-ME260 is engineered to enhance productivity while ensuring a safe working environment. Overall, this machine exemplifies the future of industrial equipment, bringing together technology and efficiency for optimal performance.