Agilent Technologies E1470A user manual Cascade Relays

Page 10

COM 00 010 002

011

001 012 000

COM 01

COM 02

030

022

031

021

032

020

COM 03

COM 04

050

042

051

041

052

040

COM 05

COM 10 110

102

111

101 112 100

COM 11

COM 12

130

122

131

121

132

120

COM 13

Channel Numbers are in the form bbc where

bb is the COM bank (00-05, 10-13, 20-25, or 30-33) c is the individual number (0, 1, or 2).

Channel

 

Cascade Relays

 

 

 

Numbers

K001

K002

 

K003

 

 

 

 

 

 

000

 

 

 

 

COM 00

 

 

 

 

 

 

(3:1)

 

001

 

 

 

 

 

 

002

 

 

 

 

 

 

 

K011

K012

K014

K013

 

 

010

 

 

 

 

COM 01

 

 

 

 

 

 

(6:1)

 

011

 

 

 

 

 

 

012

 

 

 

 

 

 

 

K021

K022

K024

K023

 

 

020

 

 

 

 

COM 02

 

 

 

 

 

 

(9:1)

 

021

 

 

 

 

 

 

022

 

 

 

 

 

 

 

K031

K032

K034

K033

 

 

030

 

 

 

 

COM 03

 

 

 

 

 

 

(12:1)

 

031

 

 

 

 

 

 

032

 

 

 

 

 

 

 

K041

K042

K044

K043

 

 

040

 

 

 

 

COM 04

 

 

 

 

 

 

(15:1)

 

041

 

 

 

 

 

 

042

 

 

 

 

 

 

 

K051

K052

K054

 

 

 

050

 

 

 

K056

K053

 

 

 

 

 

18:1

COM 05

 

 

 

 

 

 

 

051

 

 

 

12:1

(30:1)

 

 

 

 

 

A

052

 

 

 

 

Output

 

 

 

 

 

 

 

 

K055

 

to Right-Side

 

 

 

 

 

Board

 

 

No Connection

 

 

 

 

 

 

 

 

 

 

12:1 Input

 

 

 

 

 

K101

K102

 

K103

 

 

100

 

 

 

 

COM 10

 

 

 

 

 

 

(3:1)

 

101

 

 

 

 

 

 

102

 

 

 

 

 

 

 

K111

K112

K114

K113

 

 

110

 

 

 

 

COM 11

 

 

 

 

 

 

(6:1)

 

111

 

 

 

 

 

 

112

 

 

 

 

 

 

 

K121

K122

K124

K123

 

 

120

 

 

 

 

COM 12

 

 

 

 

 

 

(9:1)

 

121

 

 

 

 

 

 

122

 

 

 

 

 

 

 

K131

K132

K134

K133

 

 

130

 

 

 

 

COM 13

 

 

 

 

 

 

(12:1)

 

131

 

 

 

 

 

 

132

 

 

 

 

 

 

Figure 1-2. Cascade RF Switch Switching Diagram (continued on next page)

10 Configuring the RF Switch

Chapter 1

Image 10
Contents E1470-90002 Page Contents Appendix C RF Switch Error Messages Index Agilent Technologies Warranty Statement Government Restricted RightsSafety Symbols Documentation HistoryDeclares, that the product Product Name Manufacturer’s NameManufacturer’s Address Model NumberPage Switching Diagram Using This ChapterChapter Cascade Relays COM 33 332 Configuring the RF Switch Chapter Creating Multiple MultiplexersChapter Configuring the RF Switch RF Switch ConfigurationMaximum POWER. The maximum RF power that can be applied On this moduleSetting the Logical Address Setting the Interrupt Request Level Connecting User Wiring Installing User Wiring Configuring the RF Switch ChapterAssembling SMB Connector Jacks SMB Connectors and Connector HousingsUser Connections Wiring Installing Device Drivers RF SwitchAddressing the Switch Programming the RF Switch ChapterChapter Programming the RF Switch Programming ExamplesProgramming the RF Switch Chapter Example Closing a Signal Path Example Opening Closing Signal Paths Example Saving Recalling Module States Programming the RF Switch Chapter Scpi Commands Format Command TypesCommon Commands Format Chapter RF Switch Command ReferenceLinking Commands Scpi Command ReferenceRF Switch Command Reference Chapter DIAGnostic DIAGnosticCLOSeDIAGnosticOPEN relay,relay... opens individual relays on DIAGnosticCLOSe?DIAGnosticOPEN Reset to its power-on state Common to NCDIAGnosticOPEN? DIAGOPEN333DIAGnosticRELAY? RSTDIAGThis programCLOS042,043,053,054,256REL?returnsROUTe ROUTePATHCOMMonExample Closing Channel Path 10002 SYSTem SYSTemERRor?SYSTemVERSion? Ieee 488.2 Common Commands Quick Reference CommandCommands Quick Reference DescriptionAppendix a RF Switch Specifications Appendix aRF Switch Specifications Appendix a Register Addressing Appendix BAbout This Appendix Addressing OverviewBase Address Figure B-1. Register Address Locations Within VXI A16A16 Address Space Outside the Command Module Table B-2. Register Map Register DefinitionsTable B-1. General Register-based Programming Method Register-Based Programming Appendix BTable B-3. Status Register Bit Patterns read Table B-4. Control Register Bit Pattern writeRelay Control Registers Vxie Table B-10. Writing to Relay Control Registers Register Programming Example Create and open a device sessionWait 5 seconds before resetting module Void errhandler /* Error Handling Routine Register-Based Programming Appendix B Appendix C RF Switch Error Messages Appendix CRF Switch Error Messages Appendix C Index IndexIndex E1470-90002