Agilent Technologies E1470A user manual Manufacturer’s Name, Manufacturer’s Address, Model Number

Page 7

 

 

DECLARATION OF CONFORMITY

 

 

 

 

According to ISO/IEC Guide 22 and CEN/CENELEC EN 45014

 

 

 

 

 

 

 

Manufacturer’s Name:

 

Agilent Technologies, Inc.

 

Manufacturer’s Address:

 

 

 

 

 

Measurement Products Unit

 

 

 

815 14th Street S.W.

 

 

 

Loveland, CO 80537 USA

 

Declares, that the product

 

 

 

 

Product Name:

 

 

 

 

 

Cascade RF Switch

 

Model Number:

 

E1470A

 

Product Options:

 

This declaration includes all options of the above product(s).

 

 

 

 

 

 

Conforms with the following European Directives:

The product herewith complies with the requirements of the Low Voltage Directive 73/23/EEC and the EMC Directive 89/336/EEC and carries the CE Marking accordingly.

Conforms with the following product standards:

 

EMC

Standard

Limit

 

IEC 61326-1:1997 + A1:1998 / EN 61326-1:1997 + A1:1998

 

 

CISPR 11:1997 + A1:1997 / EN 55011-1991

Group 1, Class A [1]

 

IEC 61000-4-2:1995+A1998 / EN 61000-4-2:1995

4 kV CD, 8 kV AD

 

IEC 61000-4-3:1995 / EN 61000-4-3:1995

3 V/m, 80-1000 MHz

 

IEC 61000-4-4:1995 / EN 61000-4-4:1995

0.5 kV signal lines, 1 kV power lines

 

IEC 61000-4-5:1995 / EN 61000-4-5:1995

0.5 kV line-line, 1 kV line-ground

 

IEC 61000-4-6:1996 / EN 61000-4-6:1996

3 V, 0.15-80 MHz

 

IEC 61000-4-11:1994 / EN 61000-4-11:1994

1 cycle, 100%

 

Canada: ICES-001:1998

 

 

Australia/New Zealand: AS/NZS 2064.1

 

Safety

IEC 61010-1:1990+A1:1992+A2:1995 / EN 61010-1:1993+A2:1995

 

 

Canada: CSA C22.2 No. 1010.1:1992

 

 

UL 3111-1

 

Supplemental Information:

[1] The product was tested in a typical configuration with Agilent Technologies test systems.

September 5, 2000

Date

Name

Quality Manager

Title

For further information, please contact your local Agilent Technologies sales office, agent or distributor. Authorized EU-representative: Agilent Technologies Deutschland GmbH, Herrenberger Straβ e 130, D 71034 Böblingen, Germany

Revision: A.03

Issue Date: 09/05/00

7

Image 7
Contents E1470-90002 Page Contents Appendix C RF Switch Error Messages Index Government Restricted Rights Agilent Technologies Warranty StatementDocumentation History Safety SymbolsModel Number Manufacturer’s NameManufacturer’s Address Declares, that the product Product NamePage Switching Diagram Using This ChapterChapter Cascade Relays COM 33 332 Creating Multiple Multiplexers Configuring the RF Switch ChapterOn this module RF Switch ConfigurationMaximum POWER. The maximum RF power that can be applied Chapter Configuring the RF SwitchSetting the Logical Address Setting the Interrupt Request Level Installing User Wiring Configuring the RF Switch Chapter Connecting User WiringSMB Connectors and Connector Housings Assembling SMB Connector JacksUser Connections Wiring RF Switch Installing Device DriversProgramming the RF Switch Chapter Addressing the SwitchProgramming Examples Chapter Programming the RF SwitchProgramming the RF Switch Chapter Example Closing a Signal Path Example Opening Closing Signal Paths Example Saving Recalling Module States Programming the RF Switch Chapter Chapter RF Switch Command Reference Command TypesCommon Commands Format Scpi Commands FormatLinking Commands Scpi Command ReferenceRF Switch Command Reference Chapter DIAGnosticCLOSe DIAGnosticReset to its power-on state Common to NC DIAGnosticCLOSe?DIAGnosticOPEN DIAGnosticOPEN relay,relay... opens individual relays onDIAGOPEN333 DIAGnosticOPEN?RSTDIAGThis programCLOS042,043,053,054,256REL?returns DIAGnosticRELAY?ROUTePATHCOMMon ROUTeExample Closing Channel Path 10002 SYSTem SYSTemERRor?SYSTemVERSion? Command Ieee 488.2 Common Commands Quick ReferenceDescription Commands Quick ReferenceAppendix a Appendix a RF Switch SpecificationsRF Switch Specifications Appendix a Addressing Overview Appendix BAbout This Appendix Register AddressingFigure B-1. Register Address Locations Within VXI A16 Base AddressA16 Address Space Outside the Command Module Register-Based Programming Appendix B Register DefinitionsTable B-1. General Register-based Programming Method Table B-2. Register MapTable B-4. Control Register Bit Pattern write Table B-3. Status Register Bit Patterns readRelay Control Registers Vxie Table B-10. Writing to Relay Control Registers Create and open a device session Register Programming ExampleWait 5 seconds before resetting module Void errhandler /* Error Handling Routine Register-Based Programming Appendix B Appendix C Appendix C RF Switch Error MessagesRF Switch Error Messages Appendix C Index IndexIndex E1470-90002