00-05,10-13,20-25,30-33
000-002,010-012,020-022,030-032,040-042,050-052,100-102,110-112,120-122,130-132,200-202,210-212,220-222,230-232,240-242,250-252,300-302,310-312,320-322,330-332
!Connects COMMON in Bank 02 !to channel 1 in bank 00

Example Closing Channel Path

[ROUTe:]PATH[:COMMon]?PATH2,1

[ROUTe:]PATH[:COMMon]?<comm>,<channel> returns either a 1 or a 0 indicating whether the specified path is closed (continuity exists) or open (the signal path is broken). <comm> is a 2-digit number and <channel> is a 3-digit number.

Parameters

NameTypeRange of Values

<comm> numeric

<channel> numeric

Comments Continuity Results. The output buffer contains an unquoted string signifying the result: 0 = the specified path does NOT have continuity or 1 = the specified path DOES have continuity

Command is Hardware Readback. PATH? is a hardware readback command. It returns the current state of the hardware controlling the specified path. PATH? does not account for a failed relay.

NOTE Use PATH? to determine if a path is closed. Closing one path may open another path if both paths use the same relays. See Chapter 1 to determine if this might happen.

Invalid Values. Invalid <comm> and <channel> values or combinations may cause one of the following errors:

2001, “Invalid Channel Number” for invalid channel< >

2023, “Invalid Common Bank Number” for invalid comm< >.

2024, “Invalid Source Bank Number” for invalid channel< >

2025, “Invalid common-source combination” for invalid combination of <comm> and <channel> parameters.

*RST Condition. Channel bb0 connects to COM bb for all 3-to-1 multiplexer banks. This is equivalent to PATH bb,bb0 (where bb is the <comm> number).

34 RF Switch Command Reference

Chapter 3

Image 34
Contents E1470-90002 Page Contents Appendix C RF Switch Error Messages Index Agilent Technologies Warranty Statement Government Restricted RightsSafety Symbols Documentation HistoryDeclares, that the product Product Name Manufacturer’s NameManufacturer’s Address Model NumberPage Switching Diagram Using This ChapterChapter Cascade Relays COM 33 332 Configuring the RF Switch Chapter Creating Multiple MultiplexersChapter Configuring the RF Switch RF Switch ConfigurationMaximum POWER. The maximum RF power that can be applied On this moduleSetting the Logical Address Setting the Interrupt Request Level Connecting User Wiring Installing User Wiring Configuring the RF Switch ChapterAssembling SMB Connector Jacks SMB Connectors and Connector HousingsUser Connections Wiring Installing Device Drivers RF SwitchAddressing the Switch Programming the RF Switch ChapterChapter Programming the RF Switch Programming ExamplesProgramming the RF Switch Chapter Example Closing a Signal Path Example Opening Closing Signal Paths Example Saving Recalling Module States Programming the RF Switch Chapter Scpi Commands Format Command TypesCommon Commands Format Chapter RF Switch Command ReferenceLinking Commands Scpi Command ReferenceRF Switch Command Reference Chapter DIAGnostic DIAGnosticCLOSeDIAGnosticOPEN relay,relay... opens individual relays on DIAGnosticCLOSe?DIAGnosticOPEN Reset to its power-on state Common to NCDIAGnosticOPEN? DIAGOPEN333DIAGnosticRELAY? RSTDIAGThis programCLOS042,043,053,054,256REL?returnsROUTe ROUTePATHCOMMonExample Closing Channel Path 10002 SYSTem SYSTemERRor?SYSTemVERSion? Ieee 488.2 Common Commands Quick Reference CommandCommands Quick Reference DescriptionAppendix a RF Switch Specifications Appendix aRF Switch Specifications Appendix a Register Addressing Appendix BAbout This Appendix Addressing OverviewBase Address Figure B-1. Register Address Locations Within VXI A16A16 Address Space Outside the Command Module Table B-2. Register Map Register DefinitionsTable B-1. General Register-based Programming Method Register-Based Programming Appendix BTable B-3. Status Register Bit Patterns read Table B-4. Control Register Bit Pattern writeRelay Control Registers Vxie Table B-10. Writing to Relay Control Registers Register Programming Example Create and open a device sessionWait 5 seconds before resetting module Void errhandler /* Error Handling Routine Register-Based Programming Appendix B Appendix C RF Switch Error Messages Appendix CRF Switch Error Messages Appendix C Index IndexIndex E1470-90002