Altinex MT105-120/121 manual 14. …P Path, 16. IO, Clr

Page 15

MULTI-TASKER™

14.[…P] – PATH

This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card can be preloaded. See the examples in the ON and OFF command descriptions.

Example:

There is an MT105-120in slot #4. Currently, Input 1 is connected to all outputs and all outputs are ON. The PATH command has been used to set Input 2 to Output 1 and turn OFF Outputs 2 and 3 at the same time. If checking the status prior to sending the [SW] command, the feedback will appear as follows for the above connection settings:

In1-Out1 ON P=2

In1-Out2 ON P=OFF

In1-Out3 ON P=OFF

In1-Out4 ON

In1-Out5 ON

In1-Out6 ON

In1-Out7 ON

The notation "P=" at the end of the line indicates the path condition is active. "P=2" on the Output 1 line indicates that after the [SW] command, Input 2 will be connected to Output 1.

The notation "P=OFF" on lines 2 and 3 indicates that Outputs 2 and 3 will be turned OFF after the [SW] command is executed.

15. [SW] – SWITCH

This command immediately connects inputs and outputs previously set with the PATH command. The command switches all paths set on this card and all other cards in the enclosure.

Example:

The following commands set the path for turning ON Output 1 of the card in slot #6 and turning OFF Output 3 of the card in slot #7. Nothing happens until the [SW] command is sent. At that time, Output 1 will be enabled and Output 3 will be disabled.

[ON1C6P]

[OFF3C7P]

[SW]

16.[IO]

This command will connect a single input with one or all outputs. It will not effect the ON/OFF status of the output.

Command Format: [IxOyCnUi]

x = Input (x = # from 1 to max inputs)

y = Output (y = # from 1 to max, or [ for all)

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

An MT105-120is in slot #4 Connect Input 1 to all outputs by sending the command [I1O[C4]. After the command is sent, Input 1 will be connected to all outputs. In order to turn ON all the outputs, send the command [ONC4].

17.[CLR]

This command resets the card configuration to the factory defaults. After the [CLR] command, Input 1 will be connected to all outputs and all outputs will be ON.

Command Format: [CLRCnUi]

Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

Send the command [CLRC4] to reset the card in slot #4 to its factory defaults.

400-0362-003

14

Image 15
Contents MT105-120/121 Table of Contents MT105-120/121 InstallationCleaning GeneralAbout Your MULTI-TASKER Technical Specifications MT105-120 Front Panel Diagram 1 Typical Setup Diagram 2 MT105-120 Internal View Diagram 3 MT105-121 Internal View Description of Commands RS-232 Control1 RS-232 Interface VER CnS?CnUi STA +MA+ON Sigo SDLSDLm=s SigiFeedback Operation 10. onSingle Card Operation Path OperationOFF Group OperationOFF1C6P OFF3C7P 14. …P Path 16. IOCLR 21. WR MATmXnCiTest HelpRMC RMG24. RD Clrg CLMG1=EMPTY Menu Mode Menu Command DefinitionsUsing Menu Mode 4 MT105-120/121 Menus Menu TypesESC GO Back KEY= SET Matrix Config Save this SETTING?Reset Card to Factory Default Switch IN-OUT Enter a NumberTurn OFF Output Menu Mode ExamplesSet Sync Delay for Output 1 to 2 seconds Connect Input 2 to OutputLimited WARRANTY/RETURN Policy Card is not RecognizedNo Display