Command Format: [SIGOmCnUi]

m= Output (m = # from 1 to max outputs) Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example 1:

The card in slot #4 has Input 1 connected to Output 1 and Output 1 is turned ON. Verify the output signal is detected by sending the command [SIGO1C4] and receiving feedback equal to "1".

10.[ON]

This command will enable one or more outputs for a single card, or a group of cards.

SINGLE CARD OPERATION

Command Format: [ONmCnUi]

m= Output (m = # from 1 to max outputs) Cn = Card ID (n = # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

Example:

There is an MT105-120card in slot #5. All of the outputs on the card are OFF.

1)[ON1C5]: Turns ON only Output 1 of the MT105-120 card.

2)[ON12C5]: Turns ON Outputs 1 and 2.

3)[ONC5]: Turns ON all Outputs.

GROUP OPERATION Command Format: [ONmGkUi]

This command enables Output "m" for each card in group "k" of unit "i".

m= Output (m = # from 1 to max outputs) Gk = Group number (k = # from 1-8)

Ui = Unit ID (i = # from 0-9)

Example:

[ON1G1]: Turns ON Output 1 for each card in Group 1. See the GROUP commands for a detailed explanation.

PATH OPERATION

This command will set the path for the output, but it is not active until the switch command, [SW], is executed. Commands ending in "P" are not executed immediately. The path for outputs on multiple cards or the same card may be preloaded.

Command Format: [ONmCnUiP]

m= Output (m = # from 1 to max outputs) Cn = Card ID (n = slot # from 1 to max slots)

Ui = Unit ID (i = # from 0 to 9)

P= Path

Example:

There are two MT105-120cards in slots 6 and

7.Enable Output 1 of card 6 and Output 3 of card 7 simultaneously. To do this, send the following commands:

[ON1C6P]

[ON3C7P]

[SW]

If "F" is included, use the [ONmCnPF] command or the [ONmCnFP] command.

FEEDBACK OPERATION

After processing a command, an OK or ER will be returned as feedback if "F" is included at the end of a command string.

Command Format: [ON…..F]

Example:

[ON1C2F]: if path is not set

[ON1C2PF]: if path is set

400-0362-003

12

Image 13
Contents MT105-120/121 Table of Contents Cleaning InstallationGeneral MT105-120/121About Your MULTI-TASKER Technical Specifications MT105-120 Front Panel Diagram 1 Typical Setup Diagram 2 MT105-120 Internal View Diagram 3 MT105-121 Internal View RS-232 Control Description of Commands1 RS-232 Interface CnS VER?CnUi +MA STA+ON SDLm=s SDLSigi SigoSingle Card Operation 10. onPath Operation Feedback OperationGroup Operation OFFOFF1C6P OFF3C7P 16. IO 14. …P PathCLR Test MATmXnCiHelp 21. WRRMG RMC24. RD CLM ClrgG1=EMPTY Menu Command Definitions Menu ModeUsing Menu Mode 4 MT105-120/121 Menus Menu TypesReset Card to Factory Default Save this SETTING?Switch IN-OUT Enter a Number ESC GO Back KEY= SET Matrix ConfigSet Sync Delay for Output 1 to 2 seconds Menu Mode ExamplesConnect Input 2 to Output Turn OFF OutputCard is not Recognized Limited WARRANTY/RETURN PolicyNo Display