Allied Telesis X600-24TS manual Safety Symbols Used in this Document, Symbol Meaning Description

Page 10

Preface

Safety Symbols Used in this Document

This document uses the safety symbols defined in Table 1.

 

 

Table 1. Safety Symbols

 

 

Symbol

Meaning

Description

 

 

 

 

 

 

 

Caution

Performing or omitting a specific action may

 

 

result in equipment damage or loss of data.

 

 

 

 

Warning

Performing or omitting a specific action may

 

 

result in electrical shock.

 

 

 

10

Image 10
Contents Installation Guide Page Electrical Safety and Emissions Standards Translated Safety Statements Contents Optional Transceiver Cable Specifications Preface Product Documentation Starting a Management Session Safety Symbols Used in this Document Symbol Meaning DescriptionWhere to Find Web-based Guides Management Software Updates Contacting Allied TelesisOverview ChapterIntroduction Switch Descriptions 10/100/1000Base-T Ports Port, SFP, and SD LEDs Slot LEDsX600-24Ts/XP Switch X600-48Ts -Front Panel X600-48Ts/XP Switch Connector Type Speed Duplex Mode Maximum Distance 10/100/1000Base-T Twisted Pair PortsMDI-X SFP Transceiver Slots XFP Transceiver Slots Shows an example of an XFP transceiverRedundant Twisted Pair Ports Models Ports and SlotsSD Card Slot X600-24Ts/XPort LEDs 10/100/1000Base- T Twisted Pair Port LEDsXFP Transceiver Slot LEDs System LEDs X600-48Ts/XPStack LEDs MstrSecure Digital LEDs Terminal Port AT-RPS3204 Redundant Power Supply AT-LBM Module AC Power Connector Overview Installing the Hardware Reviewing Safety Precautions X600 Layer 3 Gigabit Ethernet Switch Installation Guide Unpacking a Switch Installing the Power Cord Retaining Clip Installing the Switches in an Equipment Rack Mounting the Switch in a Rack Resetting the Switch 24Ts/XPCabling the Network Ports Twisted Pair and Fiber Optic Cable Specifications Twisted Pair Cable SpecificationsOptional Transceiver Cable Specifications Installing Optional Transceivers Installing an SFP TransceiverSFP Handle 1334 Installing an XFP Transceiver Cabling the Network Ports Cabling the Twisted Pair and Fiber Optic Ports Powering on a Switch Starting a Local Management Session Warranty Registration Troubleshooting Power LED is Off Twisted Pair Port Link LED is Off SFP or XFP LED is Off Transceiver is Installed but the Status is Not Present System Fault LED is Blinking System Fault LED is Steadily On Cannot Establish a Local Out-of-Band Management Session Switch Functions Intermittently Troubleshooting Environmental Specifications Physical SpecificationsAppendix a Power Specifications CertificationsPin Signal RJ-45 Twisted Pair Port PinoutsPinout Pair RJ-45 Style Serial Terminal Port Pinouts RPS 21-pin D-combo Port and Connector Pinouts Pin DefinitionPin Appendix a Technical Specifications
Related manuals
Manual 112 pages 51.04 Kb