Twisted Pair Port Link LED is Off

When a twisted pair port on the switch is connected to a properly operating end node, the Link LED for the port should be on. If a Link LED is off, do the following:

Note

A 1000Base-T connection can take from five to ten seconds to establish a link.

ˆVerify that the end node connected to the port is powered ON and is operating properly.

ˆCheck that the twisted pair cable is securely connected to the port on the switch and to the port on the end node.

ˆMake sure that the twisted pair cable does not exceed 100m (328 ft).

ˆVerify that you are using the appropriate category of twisted pair cable. For information, refer to Table 9 on page 44.

ˆDetermine if a crossover cable is required. Since the twisted pair ports feature auto MDI/MDI-X, you should be able to use a straight-through cable regardless of the type of device you connect to a port. However, if you disable Auto-Negotiation on a port and set a port’s speed and duplex mode manually, the port defaults to MDI-X. Disabling Auto- Negotiation may require manually configuring a port’s MDI/MDI-X setting or using a crossover cable.

ˆMake sure that the operating parameters of a port on the switch are compatible with the end node to which the port is connected. This may require using the switch’s operating system software.

ˆFor a switch port to successfully Auto-Negotiate its duplex mode with an end node, the end node should also be using Auto-Negotiation. Otherwise, a duplex mode mismatch can occur. A switch port using Auto-Negotiation defaults to half-duplex if it detects that the end node is not using Auto-Negotiation. This can result in a mismatch if the end node is operating at a fixed duplex mode of full-duplex.

To avoid this problem, disable Auto-Negotiation on a switch port and set the port’s speed and duplex mode manually if the end node has a fixed duplex mode of full-duplex.

ˆThe switch has a bad cable detection feature that enables it to determine if a twisted pair cable has a electrical short that might cause a network loop. If the switch detects a bad cable on a port, it does not establish a link on that port. In this situation, replace the cable.

57

Image 57
Contents Installation Guide Page Electrical Safety and Emissions Standards Translated Safety Statements Contents Optional Transceiver Cable Specifications Preface Product Documentation Starting a Management Session Symbol Meaning Description Safety Symbols Used in this DocumentWhere to Find Web-based Guides Contacting Allied Telesis Management Software UpdatesChapter OverviewIntroduction 10/100/1000Base-T Ports Port, SFP, and SD LEDs Slot LEDs Switch DescriptionsX600-24Ts/XP Switch X600-48Ts -Front Panel X600-48Ts/XP Switch 10/100/1000Base-T Twisted Pair Ports Connector Type Speed Duplex Mode Maximum DistanceMDI-X SFP Transceiver Slots Shows an example of an XFP transceiver XFP Transceiver SlotsModels Ports and Slots Redundant Twisted Pair PortsX600-24Ts/X SD Card Slot10/100/1000Base- T Twisted Pair Port LEDs Port LEDsXFP Transceiver Slot LEDs X600-48Ts/XP System LEDsMstr Stack LEDsSecure Digital LEDs Terminal Port AT-RPS3204 Redundant Power Supply AT-LBM Module AC Power Connector Overview Installing the Hardware Reviewing Safety Precautions X600 Layer 3 Gigabit Ethernet Switch Installation Guide Unpacking a Switch Installing the Power Cord Retaining Clip Installing the Switches in an Equipment Rack Mounting the Switch in a Rack 24Ts/XP Resetting the SwitchCabling the Network Ports Twisted Pair Cable Specifications Twisted Pair and Fiber Optic Cable SpecificationsOptional Transceiver Cable Specifications Installing an SFP Transceiver Installing Optional TransceiversSFP Handle 1334 Installing an XFP Transceiver Cabling the Network Ports Cabling the Twisted Pair and Fiber Optic Ports Powering on a Switch Starting a Local Management Session Warranty Registration Troubleshooting Power LED is Off Twisted Pair Port Link LED is Off SFP or XFP LED is Off Transceiver is Installed but the Status is Not Present System Fault LED is Blinking System Fault LED is Steadily On Cannot Establish a Local Out-of-Band Management Session Switch Functions Intermittently Troubleshooting Physical Specifications Environmental SpecificationsAppendix a Certifications Power SpecificationsRJ-45 Twisted Pair Port Pinouts Pin SignalPinout Pair RJ-45 Style Serial Terminal Port Pinouts Pin Definition RPS 21-pin D-combo Port and Connector PinoutsPin Appendix a Technical Specifications