Redundant Twisted Pair Ports

Four of the twisted pair ports on the x600-24-Ts and x600-24-Ts/XP switches are paired with SFP slots. The twisted pair ports are identified with the letter “R” for “Redundant” as part of their number on the faceplate of the unit. The ports and slots are listed in Table 2.

Table 2. Twisted Pair Ports Matched with SFP Slots

Models

Ports and Slots

 

 

x600-24Ts and

21R with SFP slot 21

x600-24Ts/XP

22R with SFP slot 22

 

23R with SFP slot 23

 

24R with SFP slot 24

 

 

Follow these guidelines when using these ports and slots:

ˆOnly one port in a pair can be active at a time. It can be either the twisted pair port or the corresponding SFP module.

ˆThe twisted pair port is the active port when its SFP slot is empty, or when an SFP module is installed but has not established a link to an end node.

ˆThe twisted pair port automatically changes to the redundant status mode when an SFP module establishes a link with an end node.

ˆA twisted pair port automatically transitions back to the active status when the link is lost on the SFP module.

ˆIn nearly all cases, a twisted pair port and an SFP module share the same configuration settings, including port settings, VLAN assignments, access control lists, and Spanning Tree Protocol settings.

ˆAn exception to the shared settings is port speed. If you disable Auto- Negotiation on a twisted pair port and set the speed and duplex mode manually, the speed reverts to Auto-Negotiation when an SFP module establishes a link with an end node.

23

Image 23
Contents Installation Guide Page Electrical Safety and Emissions Standards Translated Safety Statements Contents Optional Transceiver Cable Specifications Preface Product Documentation Starting a Management Session Symbol Meaning Description Safety Symbols Used in this DocumentWhere to Find Web-based Guides Contacting Allied Telesis Management Software UpdatesChapter OverviewIntroduction 10/100/1000Base-T Ports Port, SFP, and SD LEDs Slot LEDs Switch DescriptionsX600-24Ts/XP Switch X600-48Ts -Front Panel X600-48Ts/XP Switch 10/100/1000Base-T Twisted Pair Ports Connector Type Speed Duplex Mode Maximum DistanceMDI-X SFP Transceiver Slots Shows an example of an XFP transceiver XFP Transceiver SlotsModels Ports and Slots Redundant Twisted Pair PortsX600-24Ts/X SD Card Slot10/100/1000Base- T Twisted Pair Port LEDs Port LEDsXFP Transceiver Slot LEDs X600-48Ts/XP System LEDsMstr Stack LEDsSecure Digital LEDs Terminal Port AT-RPS3204 Redundant Power Supply AT-LBM Module AC Power Connector Overview Installing the Hardware Reviewing Safety Precautions X600 Layer 3 Gigabit Ethernet Switch Installation Guide Unpacking a Switch Installing the Power Cord Retaining Clip Installing the Switches in an Equipment Rack Mounting the Switch in a Rack 24Ts/XP Resetting the SwitchCabling the Network Ports Twisted Pair Cable Specifications Twisted Pair and Fiber Optic Cable SpecificationsOptional Transceiver Cable Specifications Installing an SFP Transceiver Installing Optional TransceiversSFP Handle 1334 Installing an XFP Transceiver Cabling the Network Ports Cabling the Twisted Pair and Fiber Optic Ports Powering on a Switch Starting a Local Management Session Warranty Registration Troubleshooting Power LED is Off Twisted Pair Port Link LED is Off SFP or XFP LED is Off Transceiver is Installed but the Status is Not Present System Fault LED is Blinking System Fault LED is Steadily On Cannot Establish a Local Out-of-Band Management Session Switch Functions Intermittently Troubleshooting Appendix a Physical SpecificationsEnvironmental Specifications Certifications Power SpecificationsRJ-45 Twisted Pair Port Pinouts Pin SignalPinout Pair RJ-45 Style Serial Terminal Port Pinouts Pin Definition RPS 21-pin D-combo Port and Connector PinoutsPin Appendix a Technical Specifications