Allied Telesis C613-02013-00 manual Show VLAN=ALL

Page 31

Layer 2 Switching

31

DESTROY SWITCH TRUNK=trunk

Port trunk groups can only be destroyed on the switch if no ports belong to them.

All the ports in a trunk group must belong to the same VLAN. Ports in a trunk group can be added to other VLANs, either as individual ports or as an entire group. A port in a trunk group cannot be deleted from any of the VLAN(s) to which the whole trunk group belongs, unless it is first removed from the trunk group. The members of a trunk group can be specified when it is created, and ports can be added to or removed from a trunk group using the commands:

ADD SWITCH TRUNK=trunk PORT=port-list

DELETE SWITCH TRUNK=trunk PORT={port-listALL}

Ports which are members of a trunk group must operate in full duplex mode. When a port is added to a trunk group, the speed setting for the group overrides the speed setting previously configured for the port. When a port is removed from a trunk group, the port returns to its previously configured speed and duplex mode settings. The speed of the trunk group can either be specified when it is created, or set using the command:

SET SWITCH TRUNK=trunk

[SELECT={MACSRCMACDESTMACBOTHIPSRCIPDESTIPBOTH}]

[SPEED={10M100M1000M}]

The SELECT parameter specifies the port selection criterion for the trunk group. Each packet to be sent on the trunk group is checked, using the selection criterion, and a port in the trunk group chosen down which to send the packet. If MACSRC is specified, the source MAC address is used. If MACDEST is specified, the destination MAC address is used. If MACBOTH is specified, both source and destination MAC addresses are used. If IPSRC is specified, the source IP address is used. If IPDEST is specified, the destination IP address is used. If IPBOTH is specified, both the source and destination IP addresses are used. The user of the switch should choose the value of this parameter to try to spread out the load as evenly as possible on the trunk group. The default for this parameter is MACDEST.

The SPEED parameter specifies the speed of the ports in the trunk group. For gigabit ports, only the value 1000M is allowed. For switch ports, values of 10M and 100M are allowed. The default is 100M. When a port is added to a trunk group, its current speed and duplex mode settings are ignored and the port uses the speed of the trunk group and full duplex mode.

To display information about trunks on the switch, use the command:

SHOW SWITCH TRUNK[=trunk]

To display the VLANs to which the ports in the trunk groups belong, use the command:

SHOW VLAN[=ALL]

Port trunking must be configured on both ends of the link, or network loops may result.

Rapier Switch Software Release 2.2.1 C613-02013-00 Rev A

Image 31
Contents User Guide Page Contents Documentation Roadmap Chapter Why Read This User Guide?Technical support Where To Find More InformationSwitching Features What Can the Rapier Switch Do?Routing Features Advanced Feature Licence AT-RPFL3Upgrade Optional Features Command Line Interface Simple SwitchingLogging Giving the Switch an IP AddressEntering Commands SET PasswordEnable GUI Enable AT-RPFL3Upgrade Feature LicenceEnabling the GUI Starting the GUI Graphical User InterfaceNavigating Monitoring File Subsystem User PrivilegesShow File Show System Online CLI HelpNone Configuration ScriptsSaving Configuration Entered with the GUI DramEditor Saving Configuration Entered with the CLIInstall Information Show Install Delete InstallReleases and Patches into the Switch Load METHOD=HTTP DESTINATION=FLASH Example Install Software Upgrade for Rapier SwitchSnmp and MIBs Enable SnmpShow Load Show Snmp Enable Snmp AuthenticatetrapEnabling and Disabling Switch Ports Switch PortsSTP EnabledISO8802-3 Csmacd OFFAcceptable Frames Types Autonegotiation of Port Speed and Duplex ModeSELECT=MACSRCMACDESTMACBOTHIPSRCIPDESTIPBOTH Port TrunkingShow VLAN=ALL Packet Storm Protection Port Mirroring Port security ADD Switch L3FILTER MatchEnable Switch Mirror Disable Switch Mirror INTRUSIONACTION=NONEDISCARDTRAPDISABLEVirtual LANs Example output from the Show Switch Port Intrusion commandRapier Switch User Guide Creating VLANs Without Vlan Tags Static and dynamic VLANsMarketing Vlan Switch Training Vlan Trunk ports GarpParameter Meaning Vlan TaggingFRAME=TAGGEDUNTAGGED Tagged VLANs Summary of Vlan Tagging RulesGeneric Vlan Registration Protocol Gvrp Layer 2 Switching ProcessIngress Rules Learning Process Disable Switch LearningShow Switch Enable Switch LearningEnable Switch Ageingtimer Disable Switch Ageingtimer SET Switch AGEINGTIMER=10..1000000Layer 2 Filtering Example output from the Show Switch Filter commandFRAME=UNTAGGEDTAGGED Egress RulesSET Switch QOS=P1,P2,P3,P4,P5,P6,P7,P8 Quality of ServiceShow Switch QOS Spanning Tree Port States Spanning Tree Protocol STPConfiguring STP SET STP=stpnameALL PRIORITY=0..65535 Example output from the Show STP command Parameters To display STP port information, use the command TCN Bpdu To show STP counters, use the commandINTERFACE=VLAN3 Interfaces to Layer 3 ProtocolsIgmp Snooping Purge STPSET IP Igmp TIMEOUT=1..65535 QUERYINTERVAL=1..65535 Enable IP Igmp Disable IP IgmpShow IP Igmp Group List TriggersEvent Page Show IP Interface Internet Protocol IPRouting Information Protocol RIP IP MulticastingShow IPX Circuit Novell IPXUplink Active Enable RsvpAppleTalk Resource Reservation Protocol RsvpRAW Show Rsvp Interface

C613-02013-00 specifications

The Allied Telesis C613-02013-00 is a versatile and powerful network switch designed to meet the demands of modern networking environments. This device is part of Allied Telesis's extensive range of networking solutions, catering to both enterprise and industrial applications. It is engineered for high performance, reliability, and ease of management, making it a suitable choice for organizations that require robust connectivity solutions.

One of the main features of the C613-02013-00 is its support for advanced Layer 2 switching capabilities. This provides businesses with the necessary tools to manage and direct network traffic efficiently. The switch includes support for VLAN (Virtual Local Area Network) technology, which allows for the segmentation of network traffic, enhancing both security and performance. With VLANs, organizations can isolate critical workloads and improve network management while ensuring that sensitive information is protected from unauthorized access.

Another key characteristic of the C613-02013-00 is its extensive support for Power over Ethernet (PoE). This feature enables the switch to deliver electrical power along with data over standard Ethernet cabling. This is particularly beneficial for powering devices such as IP cameras, wireless access points, and VoIP phones, reducing the need for additional power supply infrastructure. With PoE capabilities, the switch simplifies installation and enhances flexibility in deploying network devices.

The C613-02013-00 also boasts advanced network management features, including support for SNMP (Simple Network Management Protocol) for efficient monitoring and troubleshooting. This ensures that network administrators can maintain optimal performance and quickly address any issues that arise. Additionally, the switch supports network redundancy features like Rapid Spanning Tree Protocol (RSTP), which helps to prevent network loops and minimizes downtime.

In terms of physical characteristics, the C613-02013-00 is designed for durability and ease of deployment in various environments. Its compact form factor allows for effective space utilization in data centers and network closets. Moreover, it features a fanless design, making it suitable for deployment in noise-sensitive environments such as offices and classrooms.

In summary, the Allied Telesis C613-02013-00 is a robust network switch offering advanced features such as Layer 2 switching, PoE support, and comprehensive network management capabilities. Its design and performance make it an excellent choice for businesses seeking to enhance their network infrastructure with reliable and secure connectivity solutions.