Allied Telesis C613-02013-00 manual Rapier Switch User Guide

Page 36

36

Rapier Switch User Guide

indicating whether a VLAN is up or down, is passed to the Internet Protocol (IP) module. IP uses this information to determine route availability.

By default the switch is configured to include all ports as untagged members of a single default VLAN, with no VLAN tagging required on incoming frames, or added to outgoing frames. This default VLAN cannot be deleted from the switch. If all the devices on the physical LAN are to belong to the same logical LAN, that is, the same broadcast domain, then the default settings will be acceptable, and no additional VLAN configuration is required.

The ability to decouple logical broadcast domains from the physical wiring topology offers several advantages, which include:

Workstations can be grouped logically or functionally, regardless of their physical location on the network.

VLAN memberships can be changed at any time by software configuration, without moving the workstations physically, or by simply moving a cable from one port to another.

By using VLAN tagging, network servers or other network resources can be shared between different work groups without losing data isolation or security.

One port on the switch can be configured as an uplink to another 802.1Q- compatible switch. By using VLAN tagging, this one port can carry traffic from all VLANs on the switch. (With port based VLANs, one uplink port is required to uplink each VLAN to another switch.)

VLANs can consist of simple logical groupings of untagged ports, in which the ports receive and transmit untagged packets. Alternatively, VLANs can include tagged ports, which add VLAN tags to packets they transmit. A port can transmit either untagged packets or VLAN tagged packets to a VLAN of which it is a member, but not both. A port can be tagged for more than one VLAN, so that a single port can be used to uplink several VLANs to another compatible switch.

A VLAN can contain a mixture of VLAN tagged and untagged ports.

The switch is VLAN aware, in that it can accept VLAN tagged frames, and supports the VLAN switching required by such tags. A network can contain a mixture of VLAN aware devices, for instance other 802.1Q compatible switches, and VLAN unaware devices, for instance, workstations and legacy switches that do not support VLAN tagging. The switch can be configured to send VLAN tagged or untagged frames on each port, depending on whether or not the devices connected to the port are VLAN aware. By assigning a port to two different VLANs, to one as an untagged port and to another as a tagged port, it is possible for the port to transmit both VLAN-tagged and untagged frames. A port can be untagged for zero or one VLAN, and can be tagged for zero or more different VLANs. A port must belong to a VLAN at all times unless the port has been set as the mirror port for the switch.

A port can belong to only one Spanning Tree entity (STP), and STP membership is per VLAN. A port cannot be added to a VLAN that is in a different STP from the VLANs to which the port already belongs, with one exception. The exception is that an untagged port in the default VLAN, that is not tagged for any other VLANs, can be moved from the default VLAN to any other VLAN in any STP.

Rapier Switch Software Release 2.2.1 C613-02013-00 Rev A

Image 36
Contents User Guide Page Contents Documentation Roadmap Why Read This User Guide? ChapterWhere To Find More Information Technical supportWhat Can the Rapier Switch Do? Switching FeaturesRouting Features Advanced Feature Licence AT-RPFL3Upgrade Optional Features Simple Switching Command Line InterfaceGiving the Switch an IP Address Entering CommandsSET Password LoggingEnable AT-RPFL3Upgrade Feature Licence Enable GUIEnabling the GUI Graphical User Interface Starting the GUINavigating Monitoring User Privileges File SubsystemShow File Online CLI Help Show SystemConfiguration Scripts Saving Configuration Entered with the GUIDram NoneSaving Configuration Entered with the CLI EditorInstall Information Delete Install Show InstallReleases and Patches into the Switch Example Install Software Upgrade for Rapier Switch Load METHOD=HTTP DESTINATION=FLASHEnable Snmp Snmp and MIBsShow Load Enable Snmp Authenticatetrap Show SnmpSwitch Ports Enabling and Disabling Switch PortsEnabled ISO8802-3 CsmacdOFF STPAutonegotiation of Port Speed and Duplex Mode Acceptable Frames TypesPort Trunking SELECT=MACSRCMACDESTMACBOTHIPSRCIPDESTIPBOTHShow VLAN=ALL Packet Storm Protection Port Mirroring ADD Switch L3FILTER Match Enable Switch Mirror Disable Switch MirrorINTRUSIONACTION=NONEDISCARDTRAPDISABLE Port securityExample output from the Show Switch Port Intrusion command Virtual LANsRapier Switch User Guide Static and dynamic VLANs Creating VLANs Without Vlan TagsMarketing Vlan Switch Training Vlan Garp Trunk portsVlan Tagging Parameter MeaningFRAME=TAGGEDUNTAGGED Summary of Vlan Tagging Rules Tagged VLANsLayer 2 Switching Process Generic Vlan Registration Protocol GvrpIngress Rules Disable Switch Learning Learning ProcessEnable Switch Learning Enable Switch Ageingtimer Disable Switch AgeingtimerSET Switch AGEINGTIMER=10..1000000 Show SwitchExample output from the Show Switch Filter command Layer 2 FilteringEgress Rules FRAME=UNTAGGEDTAGGEDQuality of Service SET Switch QOS=P1,P2,P3,P4,P5,P6,P7,P8Show Switch QOS Spanning Tree Protocol STP Spanning Tree Port StatesConfiguring STP SET STP=stpnameALL PRIORITY=0..65535 Example output from the Show STP command Parameters To display STP port information, use the command To show STP counters, use the command TCN BpduInterfaces to Layer 3 Protocols Igmp SnoopingPurge STP INTERFACE=VLAN3Enable IP Igmp Disable IP Igmp SET IP Igmp TIMEOUT=1..65535 QUERYINTERVAL=1..65535Show IP Igmp Triggers Group ListEvent Page Internet Protocol IP Show IP InterfaceIP Multicasting Routing Information Protocol RIPNovell IPX Show IPX CircuitUplink Enable Rsvp AppleTalkResource Reservation Protocol Rsvp ActiveShow Rsvp Interface RAW

C613-02013-00 specifications

The Allied Telesis C613-02013-00 is a versatile and powerful network switch designed to meet the demands of modern networking environments. This device is part of Allied Telesis's extensive range of networking solutions, catering to both enterprise and industrial applications. It is engineered for high performance, reliability, and ease of management, making it a suitable choice for organizations that require robust connectivity solutions.

One of the main features of the C613-02013-00 is its support for advanced Layer 2 switching capabilities. This provides businesses with the necessary tools to manage and direct network traffic efficiently. The switch includes support for VLAN (Virtual Local Area Network) technology, which allows for the segmentation of network traffic, enhancing both security and performance. With VLANs, organizations can isolate critical workloads and improve network management while ensuring that sensitive information is protected from unauthorized access.

Another key characteristic of the C613-02013-00 is its extensive support for Power over Ethernet (PoE). This feature enables the switch to deliver electrical power along with data over standard Ethernet cabling. This is particularly beneficial for powering devices such as IP cameras, wireless access points, and VoIP phones, reducing the need for additional power supply infrastructure. With PoE capabilities, the switch simplifies installation and enhances flexibility in deploying network devices.

The C613-02013-00 also boasts advanced network management features, including support for SNMP (Simple Network Management Protocol) for efficient monitoring and troubleshooting. This ensures that network administrators can maintain optimal performance and quickly address any issues that arise. Additionally, the switch supports network redundancy features like Rapid Spanning Tree Protocol (RSTP), which helps to prevent network loops and minimizes downtime.

In terms of physical characteristics, the C613-02013-00 is designed for durability and ease of deployment in various environments. Its compact form factor allows for effective space utilization in data centers and network closets. Moreover, it features a fanless design, making it suitable for deployment in noise-sensitive environments such as offices and classrooms.

In summary, the Allied Telesis C613-02013-00 is a robust network switch offering advanced features such as Layer 2 switching, PoE support, and comprehensive network management capabilities. Its design and performance make it an excellent choice for businesses seeking to enhance their network infrastructure with reliable and secure connectivity solutions.