Allied Telesis SB251-08 manual Features in SB251-02, PCR Module Switch Network affecting No

Page 8

8

Patch Release Note

PCR: 03142

Module: SWI

Level: 1

If a BIST was run at low temperatures, for example 5 or 10 degress celcius, on a G8 card, then a watchdog timer restart could occur. The switch now checks for the real course of the external interrupts that occur when running BIST.

PCR: 03148

Module: IPG

Level: 3

If the Gratuitous ARP feature was enabled on an IP interface, and an ARP packet arrived, (either ARP request, or reply) that had a Target IP address that was equal to the SenderIP address, then the ARP cache was not updated with the ARP packet’s source data. This issue has been resolved.

PCR: 03191

Module: SWI

Level: 1

If two line cards were inserted in quick succession, then a software restart could occasionally occur. This issue has been resolved.

PCR: 03192

Module: SWI

Level: 2

When the Built-In Self Test was run, a fault would occasionally be reported which said that a MAC address was not learnt during the loopback test. The ports in the BIST loopback test now remain in loopback.

Features in SB251-02

Table 7: Patch file details for Patch SB251-02.

Base Software Release File

sb-251.rez

 

 

Patch Release Date

25-Jan-2003

 

 

Compressed Patch File Name

sb251-02.paz

 

 

Compressed Patch File Size

48608 bytes

 

 

Patch SB251-02 includes all issues resolved and enhancements released in previous patches for Software Release 2.5.1, and the following enhancements:

PCR: 02553

Module: SWITCH

Network affecting: No

64 bit MIB counters were not incremented or cleared for port interfaces. This issue has been resolved.

PCR: 02574 Module: DVMRP

Network affecting: No

Some change actions, and the resending of prune messages were not operating correctly. This issue has been resolved.

PCR: 02582

Module: SWI

Network affecting: No

Pause flow control is now disabled by default on all ports. This improves performance of the switch when it is congested.

The DPORT parameter in the ADD SWITCH HWFILTER command was omitted when the configuration was generated. This issue has been resolved.

Patch SB251-08 for Software Release 2.5.1 C613-10361-00 REV H

Image 8
Contents Introduction Features in SB251-08 PCR Module SWI LevelFeatures in SB251-07 PCR Module STP, SWI LevelFeatures in SB251-06 Features in SB251-05PCR Module SWI PCR Module SWI, Sysr LevelFeatures in SB251-04 PCR Module GUI Level2 Features in SB251-03PCR Module TCP Level3 PCR Module CORE, SWI Level PCR 03071 Module Core LevelPCR Module IPG, SWI Level PCR Module Firewall LevelFeatures in SB251-02 PCR Module Switch Network affecting NoPCR 02574 Module Dvmrp Network affecting No PCR Module SWI Network affecting NoPCR Module SWITCH, IPG Network affecting No PCR Module Firewall Network affecting NoPCR Module QOS Network affecting No PCR 03047 Module Core Network affecting NoPCR 02396 Module Dhcp Network affecting No Features in SB251-01PCR 02568 Module Core Network affecting No Availability PCR Module Ospf Network affecting NoPCR Module SWI Classifier Network affecting No PCR Module IPG, SWI Network affecting NoPatch Release Note