8 | Patch Release Note |
PCR: 03142 | Module: SWI | Level: 1 |
If a BIST was run at low temperatures, for example 5 or 10 degress celcius, on a G8 card, then a watchdog timer restart could occur. The switch now checks for the real course of the external interrupts that occur when running BIST.
PCR: 03148 | Module: IPG | Level: 3 |
If the Gratuitous ARP feature was enabled on an IP interface, and an ARP packet arrived, (either ARP request, or reply) that had a Target IP address that was equal to the SenderIP address, then the ARP cache was not updated with the ARP packet’s source data. This issue has been resolved.
PCR: 03191 | Module: SWI | Level: 1 |
If two line cards were inserted in quick succession, then a software restart could occasionally occur. This issue has been resolved.
PCR: 03192 | Module: SWI | Level: 2 |
When the
Features in SB251-02
Table 7: Patch file details for Patch
Base Software Release File | |
|
|
Patch Release Date | |
|
|
Compressed Patch File Name | |
|
|
Compressed Patch File Size | 48608 bytes |
|
|
Patch
PCR: 02553 | Module: SWITCH | Network affecting: No |
64 bit MIB counters were not incremented or cleared for port interfaces. This issue has been resolved.
PCR: 02574 Module: DVMRP | Network affecting: No |
Some change actions, and the resending of prune messages were not operating correctly. This issue has been resolved.
PCR: 02582 | Module: SWI | Network affecting: No |
Pause flow control is now disabled by default on all ports. This improves performance of the switch when it is congested.
The DPORT parameter in the ADD SWITCH HWFILTER command was omitted when the configuration was generated. This issue has been resolved.
Patch