Allied Telesis SB251-08 manual Features in SB251-03, PCR Module TCP Level3, PCR Module GUI Level2

Page 6

6

Patch Release Note

PCR: 03243

Module: SWI

Level: 2

After autonegotiation had finished between two ports, the port on the SwitchBlade would not show link up status when the SHOW SWITCH PORT command was executed. The autonegotiation process is now restarted if autonegotiation is completed and the link is shown as down.

PCR: 03249

Module: SWI

Level: 4

The LEDs on line cards now continue to flash when activity exists. Previously if a cable was connected and disconnected to Line 48 and G8 ports, with traffic being transmitted from the other end, then the LED would stop flashing, even when there was activity on the link.

Features in SB251-03

Patch file details are listed in Table 6.

Table 6: Patch file details for Patch SB251-03.

Base Software Release File

sb-251.rez

 

 

Patch Release Date

12-Mar-2003

 

 

Compressed Patch File Name

sb251-03.paz

 

 

Compressed Patch File Size

68784 bytes

 

 

Patch SB251-03 includes all issues resolved and enhancements released in previous patches for Software Release 2.5.1, and the following enhancements:

PCR: 02361

Module: SWI

Level: 4

The SwitchBlade mirror port field on the second instance of a switch chip was displaying as though it was the first instance. For example, if 2.26 was configured as the mirror port, the GUI mirror object would return 2.2. The first chip instance was not affected. This issue has been resolved.

PCR: 02527

Module: TCP

Level:3

TCP6 did not send a TCP Reset message under some circumstances, for example when the Telnet server was disabled. This issue has been resolved.

PCR: 03025

Module: GUI

Level:2

A buffer address was incrementing and not returning buffers for reuse when the command line interface was accessed via the GUI interface. This issue has been resolved.

PCR: 03055

Module: SWI

Level: 4

If the SET SWITCH BLADE command was executed with the default settings, then the default settings were added to the configuration file. The SET SWITCH BLADE settings are now only added to the configuration file if they differ from the default settings.

Patch SB251-08 for Software Release 2.5.1 C613-10361-00 REV H

Image 6
Contents Introduction Features in SB251-08 PCR Module SWI LevelFeatures in SB251-07 PCR Module STP, SWI LevelPCR Module SWI Features in SB251-06Features in SB251-05 PCR Module SWI, Sysr LevelFeatures in SB251-04 Features in SB251-03 PCR Module TCP Level3PCR Module GUI Level2 PCR Module IPG, SWI Level PCR Module CORE, SWI LevelPCR 03071 Module Core Level PCR Module Firewall LevelPCR 02574 Module Dvmrp Network affecting No Features in SB251-02PCR Module Switch Network affecting No PCR Module SWI Network affecting NoPCR Module QOS Network affecting No PCR Module SWITCH, IPG Network affecting NoPCR Module Firewall Network affecting No PCR 03047 Module Core Network affecting NoFeatures in SB251-01 PCR 02568 Module Core Network affecting NoPCR 02396 Module Dhcp Network affecting No PCR Module SWI Classifier Network affecting No AvailabilityPCR Module Ospf Network affecting No PCR Module IPG, SWI Network affecting NoPatch Release Note