Allied Telesis SB251-08 manual PCR Module CORE, SWI Level, PCR 03071 Module Core Level

Page 7

Patch SB251-08 For SwitchBlade 4000 Series Switches and AT-9800 Series Switches

7

PCR: 03060

Module: CORE, SWI

Level: 3

Support has been added, to the MIB-2 interface MIB, for the port interface.

This means that port counters can now be shown.

PCR: 03066

Module: SWI

Level: 2

If a hardware filter was added to the switch, with a source VLAN and a destination port of 1, then a host connected to the switch could not PING a host on a different port. This issue has been resolved.

PCR: 03071 Module: CORE

Level: 2

An unexpected restart that occurred when upgrading a SwitchBlade from

Release 2.4.4 to Release 2.5.1 was caused by NVS generating an SNMP trap.

This issue has been resolved.

PCR: 03079

Module: IPG, SWI

Level: 1

Static routes were occasionally not added to all hardware tables across all instances. This would affect connectivity if an instance had a default route added to its table that pointed out one of its ports. This issue has been resolved.

PCR: 03088

Module: SWI

Level: 2

Ports could not be added to the default VLAN after a hotswap, if the default VLAN was Protocol, Subnet, MAC address, or Limited protocol based. This issue has been resolved.

PCR: 03105

Module: FIREWALL

Level: 3

Incorrect handling of TCP sessions, and poor load balancing performance could be caused by TCP virtual balancers not selecting a new resource if required. This issue has been resolved.

PCR: 03112

Module: IPV6

Level: 3

The ADD IPV6 ND command now has a PORT parameter which means that it can be associated with the VLAN parameter.

PCR: 03118

Module: CORE

Level: 4

Changes have been made to the SysDescription.

PCR: 03119

Module: CLASSIFIER

Level: 4

TCP source and TCP destination ports were swapped when viewed in the

GUI. This issue has been resolved.

PCR: 03138

Module: SWI

L evel: 2

Packets that were sent out a default route could have an incorrect source IP address, if the interface route to the destination IP address existed but was down. This issue has been resolved.

PCR: 03141

Module: IPG

Level: 3

Packets could be sent with an incorrect source address if a route was added to a VLAN and another VLAN had an IP interface configured that was in the same subnet as the route. This issue has been resolved.

Patch SB251-08 for Software Release 2.5.1 C613-10361-00 REV H

Image 7
Contents Introduction PCR Module SWI Level Features in SB251-08PCR Module STP, SWI Level Features in SB251-07PCR Module SWI, Sysr Level Features in SB251-06Features in SB251-05 PCR Module SWIFeatures in SB251-04 PCR Module TCP Level3 Features in SB251-03PCR Module GUI Level2 PCR Module Firewall Level PCR Module CORE, SWI LevelPCR 03071 Module Core Level PCR Module IPG, SWI LevelPCR Module SWI Network affecting No Features in SB251-02PCR Module Switch Network affecting No PCR 02574 Module Dvmrp Network affecting NoPCR 03047 Module Core Network affecting No PCR Module SWITCH, IPG Network affecting NoPCR Module Firewall Network affecting No PCR Module QOS Network affecting NoPCR 02568 Module Core Network affecting No Features in SB251-01PCR 02396 Module Dhcp Network affecting No PCR Module IPG, SWI Network affecting No AvailabilityPCR Module Ospf Network affecting No PCR Module SWI Classifier Network affecting NoPatch Release Note