Allied Telesis SB251-08 manual Availability, PCR Module Ospf Network affecting No

Page 11

Patch SB251-08 For SwitchBlade 4000 Series Switches and AT-9800 Series Switches

11

PCR: 02587

Module: OSPF

Network affecting: No

When OSPF was enabled on startup, an OSPF interface would sometimes stay in the DOWN state. This issue has been resolved.

PCR: 03001

Module: SWI CLASSIFIER

Network affecting: No

The following parameters have been changed CREATE CLASSIFIER, SET

CLASSIFIER and SHOW CLASSIFIER commands:

The MACTYPE parameter has been changed to MACTYPE={L2UCASTL2MCASTL2BCASTANY}. This resolves an error with internal hardware tables.

The number of user-specified protocols in the PROTOCOL parameter has been increased from three to seven.

The minimum value of the IPXDADDRESS parameter has been decreased from 10000000 to 00000001.

PCR: 03006

Module: SWI

Network affecting: No

An issue which sometimes resulted in a broadcast storm within the internal ports on the SwitchBlade, a reduction in bandwidth, and a loss of pinging has been resolved.

PCR: 3008

Module: SWI

Network affecting: No

An issue which caused pings to fail when a control card was inserted in the left hand slot to act as a slave, has been resolved.

PCR: 03014

Module: IPG, SWI

Network affecting: No

Support has been added to allow for multicasting to any number of overlapping VLANs up to the maximum number of multicast forwarding entries.

PCR: 03018

Module: SWI

Network affecting: No

An issue with pings failing after network host routes disappeared from the switch due to an IP hashing error has been resolved.

PCR: 03020

Module: SWI

Network affecting: No

An issue with an interrupt occurring when waiting on the MDIO which caused the MDIO to read or write incorrect information has been resolved.

PCR: 03021

Module: SWI

Network affecting: No

Ping would sometimes not work correctly after a 48 line card was extracted, and after a restart reboot. This issue has been resolved.

Availability

Patches can be downloaded from the Software Updates area of the Allied Telesyn web site at www.alliedtelesyn.co.nz/support/updates/patches.html. A licence or password is not required to use a patch.

Patch SB251-08 for Software Release 2.5.1 C613-10361-00 REV H

Image 11
Contents Introduction PCR Module SWI Level Features in SB251-08PCR Module STP, SWI Level Features in SB251-07PCR Module SWI, Sysr Level Features in SB251-06Features in SB251-05 PCR Module SWIFeatures in SB251-04 PCR Module GUI Level2 Features in SB251-03PCR Module TCP Level3 PCR Module Firewall Level PCR Module CORE, SWI LevelPCR 03071 Module Core Level PCR Module IPG, SWI LevelPCR Module SWI Network affecting No Features in SB251-02PCR Module Switch Network affecting No PCR 02574 Module Dvmrp Network affecting NoPCR 03047 Module Core Network affecting No PCR Module SWITCH, IPG Network affecting NoPCR Module Firewall Network affecting No PCR Module QOS Network affecting NoPCR 02396 Module Dhcp Network affecting No Features in SB251-01PCR 02568 Module Core Network affecting No PCR Module IPG, SWI Network affecting No AvailabilityPCR Module Ospf Network affecting No PCR Module SWI Classifier Network affecting NoPatch Release Note