Patch | 11 |
PCR: 02587 | Module: OSPF | Network affecting: No |
When OSPF was enabled on startup, an OSPF interface would sometimes stay in the DOWN state. This issue has been resolved.
PCR: 03001 | Module: SWI CLASSIFIER | Network affecting: No |
The following parameters have been changed CREATE CLASSIFIER, SET
CLASSIFIER and SHOW CLASSIFIER commands:
•The MACTYPE parameter has been changed to MACTYPE={L2UCASTL2MCASTL2BCASTANY}. This resolves an error with internal hardware tables.
•The number of
•The minimum value of the IPXDADDRESS parameter has been decreased from 10000000 to 00000001.
PCR: 03006 | Module: SWI | Network affecting: No |
An issue which sometimes resulted in a broadcast storm within the internal ports on the SwitchBlade, a reduction in bandwidth, and a loss of pinging has been resolved.
PCR: 3008 | Module: SWI | Network affecting: No |
An issue which caused pings to fail when a control card was inserted in the left hand slot to act as a slave, has been resolved.
PCR: 03014 | Module: IPG, SWI | Network affecting: No |
Support has been added to allow for multicasting to any number of overlapping VLANs up to the maximum number of multicast forwarding entries.
PCR: 03018 | Module: SWI | Network affecting: No |
An issue with pings failing after network host routes disappeared from the switch due to an IP hashing error has been resolved.
PCR: 03020 | Module: SWI | Network affecting: No |
An issue with an interrupt occurring when waiting on the MDIO which caused the MDIO to read or write incorrect information has been resolved.
PCR: 03021 | Module: SWI | Network affecting: No |
Ping would sometimes not work correctly after a 48 line card was extracted, and after a restart reboot. This issue has been resolved.