8 | Patch Release Note |
PCR: 40540 | Module: SWI | Level: 2 |
Problems could occur if hardware filters or QOS policies were created using a classifier matching on: a Layer 2 attribute other than MAC Destination (e.g. MACSA or VLAN ID), and one or more other parameters that match on IPv4 frames (e.g. IP address, UDP/TCP parameters), and another classifier matching on Layer 2 attributes only.
The possible problems were; a generic Layer 2 match only succeeding if the frame was not of IP type, or
PCR: 40541 | Module: CLASSIFIER | Level: 2 |
If a classifier was created that used the ethformat and protocol parameters, the resulting entry in a script created using the create config command or show config dynamic commands was not always correct. This issue has been resolved.
PCR: 40543 Module: SWMX | Level: 2 |
When a Novell IPX packet was received by a port in a a
PCR: 40544 Module: VLAN | Level: 2 |
1.) A port was remaining in the default VLAN after having been added to a nested VLAN.
2.) A port was being returned to the default VLAN when deleted from one nested VLAN even if it was still a member of another nested VLAN.
3.) A port associated with a protocol or subnet rule was not being returned to the default VLAN when deleted from a nested VLAN.
These issues have all been resolved.
PCR: 40549 | Module: SWI | Level: 2 |
The receipt of two IP packets whose destination IP addresses were subnet addresses caused the switch to reboot. This issue has been resolved.
PCR: 40550 Module: SWMX | Level: 2 |
Wrong bits were being set in the ASIC rule table for classifiers that matched on IPX source socket. As the result, the classifiers would match on incorrect values of IPX source socket. This issue has been resolved.
PCR: 40554 | Module: QoS | Level: 2 |
Some MIB values for the
PCR: 40561 Module: SWMX | Level: 2 |
After the disable switch learn command had been executed successfully, automatic MAC learning was still operating. This issue has been resolved.