Allied Telesis GS900/5E manual Duplex Mode Store Forward

Page 19

Duplex Mode

Store and

Forward

Backpressure and Flow Control

AT-GS900/16, AT-GS900/24 Fanless Gigabit Ethernet Switches Installation Guide

Duplex mode refers to how an end-node receives and transmits data. If an end-node can either receive or transmit data, but not both simultaneously, the end-node is operating in what is referred to as half-duplex mode. If an end-node can both receive and transmit data simultaneously, the end- node is said to be operating in full-duplex mode. Naturally, an end-node capable of operating in full-duplex can handle data much faster than an end-node that can only operate in half-duplex mode.

The twisted pair ports on the AT-GS900/16 and AT-GS900/24 switches can operate in half- or full-duplex mode for 10/100 Mbps and full-duplex for 1000 Mbps. They are IEEE 802.3u-compliant and use Auto-Negotiation to set the duplex mode setting for you automatically.

An AT-GS900/16 or AT-GS900/24 switch uses store and forward as the method for receiving and transmitting frames. When a Ethernet frame is received on a switch port, the switch does not retransmit the frame from the destination port until it has received the entire frame and stored the frame in a port buffer. It then examines the frame to determine if it is a valid frame. Invalid frames, such as fragments or runts, are discarded by the switch. This process insures that only valid frames are transmitted from the switch ports and that damaged frames are not propagated on your network.

To maintain the orderly movement of data between the end-nodes, an Ethernet switch may periodically need to signal an end-node to stop sending data. This can occur under several circumstances. For example, if two end-nodes are operating at different speeds, the switch, while transferring data between the end-nodes, might need to instruct the faster end-node to stop transmitting data to allow the slower end-node to catch up. An example of this would be when a server operating at 100 Mbps is sending data to a workstation operating at only 10 Mbps.

How a switch signals an end-node to stop transmitting data differs depending on the duplex mode of the end-node and switch port. A twisted pair port operating in half-duplex mode stops an end-node from transmitting data by forcing a collision. A collision on an Ethernet network occurs when two end-nodes attempt to transmit data using the same data link at the same time. A collision causes an end-node to stop sending data, wait for a brief period of time, and then retransmit the same data. Once the switch is ready to receive data again, the switch stops forcing collisions. This is referred to as backpressure.

A port operating in full-duplex mode uses PAUSE frames, as specified in the IEEE 802.3x standard, to stop the transmission of data from an end- node. Whenever the switch wants an end-node to stop transmitting data, it issues this frame. The frame instructs the end-node to cease transmission for a period of time specified within the frame. The switch continues to issue PAUSE frames until it is ready again to receive data from the end- node. This is referred to as flow control.

19

Image 19
Contents Installation Guide Page Electrical Safety and Emissions Standards Translated Safety Statements Contents Contents Preface Symbol Meaning Description Safety Symbols Used in this DocumentWhere to Find Web-based Guides Contacting Allied Telesis WarrantyManagement Software Updates Chapter Product DescriptionStandards FeaturesFront Panels ComponentsTwisted Pair Ports Hardware Feature DescriptionMaximum Distance AC Power Connector MAC Address Table Ethernet Switching BasicsDuplex Mode Store Forward Network Topologies Power Workgroup TopologyCollapsed Backbone Installation Reviewing Safety Precautions Selecting a Site for the Switch Speed Type of Cable Maximum Planning the InstallationUnpacking the Switch Installing the Switch on a Table or Desktop Installation Attaching the brackets to the sides of the switch Installing the Switch on a Wall1303 Page Attaching Rackmounting Brackets Installing the Switch in a Rack606 Installation Cabling the Switch Powering On the Switch Troubleshooting Power Specifications Technical SpecificationsPhysical Specifications Environmental SpecificationsRJ-45 Twisted Pair Port Connectors Safety and Electromagnetic Emissions CertificationsCompliance Standards Pin Signal