Adder Technology AdderLink IP manual Initial configuration, Part 1 Local configuration

Page 12

Configuration

Initial configuration

The initial configuration occurs as two distinct parts:

Part 1 – Local configuration

This part of the configuration takes place using the locally connected keyboard and video monitor. It allows you to set up key basic details, network essentials, modem/ISDN parameters and security key creation.

Part 2 – Remote configuration

This part of the configuration takes place using a remote connection (network or dial-up modem/ISDN). It allows fine tuning of the part 1 configuration items plus the creation of multiple user accounts and host details. Go to Part 2 - Remote configuration.



Part 1 – Local configuration

When you switch on the AdderLink IP unit for the first time it will take you (using the locally connected keyboard and video monitor) through a set up sequence consisting of four main screens:

AdderLink

IP

Unit

Config

 

 

 

 

 

AdderLink

IP Modem

Config

 

 

 

 

 

 

 

 

 

 

 

 

 

>

AdderLink

IP Network Config

>

>

 

 

 

 

 

>

Hardware

Rev

1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AdderLink

IP Secure

Keys

Firmware

Version

1.4

 

 

 

 

Server

IP

192.168.3.1

 

MAC

Address

00:0F:58:00:00:04

 

 

 

 

 

Keybd

Layout

UK

 

 

 

Client

IP

192.168.3.2

 

 

 

 

 

 

 

 

Use

DHCP

No

Random

data is required to

Admin

Passwd

 

 

 

 

Baud

Rate

115200

 

 

 

 

 

IP Address

192.168.42.154

 

generate encryption keys

Unit

Name

 

 

 

 

Init

String

ATZHS0=1

 

 

 

 

 

Net

Mask

255.255.255.0

 

for secure

VNC

access

 

Hot Keys

Ctrl+Alt

 

Gateway

 

 

 

 

 

 

Please

move

the

mouse

or

Screensaver

10

mins

 

 

 

 

 

 

 

press

keys

until the

bar

 

VNC

Port

5900

 

 

 

 

 

Time

 

21 : 27 : 31

 

 

 

Initialize Port

becomes full

 

 

 

HTTP

Port

80

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Date

 

15

Apr

2004

 

 

 

Restore

Defaults

 

 

 

 

 

Encryption

Prefer

Off

 

 

 

 

Save

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Save

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Save

  

Unit config screen

Allows you to determine a mixture of basic and fundamental setup details such as the keyboard layout, admin password, time and date.

Network config screen

Requires you to configure the various key aspects of the IP network port addressing.

Modem config screen

Allows you to optionally alter the current settings for the serial port that is used to connect a modem or ISDN terminal adapter. The IP addresses are used to emulate a two-port network connection and are suitable for most situations.

Secure keys screen

This screen uses your mouse movements or keyboard inputs to create random data. This unpredictable information is then combined with several other factors to develop the basis of the encryption keys that are used to establish secure remote links.



Controlling the local configuration menus The local menus use only the keyboard. Use the keyboard arrow keys to move the green highlight indicator to the required position. Then, either type the required information or use the left and right arrows to change multiple choice items, as appropriate.

Problems?

The AdderLink IP asks for an unknown admin password

The AdderLink IP does not display the configuration sequence

continued

11

Image 12
Contents AdderLink IP Contents Index Four simultaneous remote users Local userModem/ISDN port IP network/InternetAdderView IP features front and rear What’s in the box What you may additionally need    Mounting Single unit rack bracketsDouble unit rack brackets  Host computer or KVM switch ConnectionsLocal keyboard, video monitor and mouse IP network portTo connect a local keyboard, video monitor and mouse To connect the IP network portPower supply connection To connect the power supplyModem/ISDN port To connect a modem or Isdn portPower control port To connect and address the switch boxesInitial configuration Part 1 Local configurationPart 1 Local configuration Part 2 Remote configurationTo perform the initial local configuration Admin passwordTime and Date EncryptionEncryption settings AdderLink IP encryption settingsViewer encryption settings EncryptionWhich restore setting do I use? To restore mouse operation when hot pluggingHot plugging and mouse restoration Recognising an IntelliMouse-style mouseResetting the configuration AdderLink IP asks for an unknown admin passwordTo invoke a configuration reset by switch AdderLink IP does not display the configuration sequencePart 2 Remote configuration To perform the remote configurationNetworking issues Port settingsPositioning AdderLink IP in the network Placing AdderLink IP behind a firewallAddressing To discover a DHCP-allocated IP addressDNS addressing Firewall/router addressPlacing AdderLink IP alongside the firewall Ensuring sufficient securityPorts Power switching configuration Power control sequencesTo configure the power sequences for each host computer To control two or more ports simultaneouslyPerforming a flash upgrade To perform a flash upgradeConfigure network option Important Wait until the upgrade is completeConnecting to the AdderLink IP Local connectionTo make a local connection To view the local control menuRemote connections To avoid the ‘hall of mirrors’ effectTo connect using the VNC viewer To connect using your Web browserRemote connection by VNC viewer Remote connection by Web browserUsing the viewer window When using the viewer windowMenu bar Configure Mouse pointersHost selection To select a hostAccess mode shared/private Power controlAuto calibrate Re-synchronise mouseControls Setting the Threshold manually PhaseContrast  Connecting via dial up modem or Isdn link Downloading VNC viewer from the AdderLink IPIf you need to enter a port number Viewer encryption settings Supported web browsersWindows LinuxTroubleshooting When logging on using VNC viewer, I cannot enter a usernameGetting assistance US +1 888 275Appendix 1 Local configuration menus To access the local configuration menusUnit configuration Network configuration Modem configuration Reset configuration To reset the AdderLink IP configurationClear IP access control What is IP access control?To clear IP access control Appendix 2 VNC viewer connection options Colour/EncodingAuto select Preferred encodingInputs MiscDefaults Reload defaultsSave as defaults Save configuration file asAppendix 3 VNC viewer window options Appendix 4 Browser viewer options Encoding and colour levelSecurity Appendix 5 Remote configuration menus To access the remote configuration menusMain configuration menu Logged on users User accounts Screensaver timeout Hardware VersionFirmware Version Host Keyboard LayoutAdvanced unit configuration Idle timeoutProtocol timeout Force VNC protocolIP access control IP network maskIP gateway Setting IP access control To define a new IP access control entryTo reorder access control entries To edit/remove access control entriesSerial port configuration Power control portModem port Host configuration To create a new host entryLogging and status To copy and paste the logOccurred Click to clear All log entries Refresh ListAppendix 6 Addresses, masks and ports IP addressesNet masks Net masks the binary explanation Inside a bit-wise and functionBinary equivalent Binary octet afterCalculating the mask for IP access control Single locationsAll locations Address rangesSecurity issues with ports PortsRouter/firewall address Appendix 7 Cable and connector specifications AdderLink IP to power switch cableRS232 serial mouse to PS/2 converter cable Appendix 8 Hotkey sequence codes Warranty Safety informationOther products in the Adder range Radio Frequency Energy European EMC directive 89/336/EECFCC Compliance Statement United States United States of America Index 

AdderLink IP specifications

Adder Technology's AdderLink IP is a cutting-edge solution designed to extend and manage KVM (Keyboard, Video, Mouse) signals over IP networks. This innovative technology facilitates the remote access and control of computers and servers, making it an essential tool for organizations that require efficient management of their IT resources.

One of the main features of AdderLink IP is its ability to transmit high-resolution video signals with minimal latency. Supporting resolutions up to 4K at 60Hz, it ensures that users experience clarity and responsiveness that is comparable to direct connections. This capability is crucial for industries such as broadcasting, media production, and any environment where graphics-intensive applications are commonplace.

The AdderLink IP employs advanced digitization techniques to ensure high-quality video transmission over standard IP networks. Its use of H.264 video compression allows for efficient bandwidth usage while maintaining image integrity. With this feature, users can easily adapt to various network conditions without compromising performance.

Another standout characteristic is the support for real-time remote access through a web browser, allowing users to connect to their systems from virtually anywhere in the world. Whether for troubleshooting, maintenance, or system management, the AdderLink IP empowers IT professionals with the flexibility they need to perform their duties effectively. The built-in security protocols ensure that access is both secure and reliable.

Moreover, AdderLink IP is designed to be user-friendly. Configuration and management can be performed via an intuitive web interface, simplifying the setup process for users of all technical skill levels. Compatibility with a range of operating systems and devices further enhances its versatility.

Furthermore, the system supports multi-user access, enabling multiple operators to connect to the same devices simultaneously without conflicts. This functionality is particularly useful in collaborative environments where teams need concurrent access to critical systems.

In summary, Adder Technology's AdderLink IP stands out as a robust solution for KVM over IP needs. With its high-quality video transmission, real-time remote access, ease of use, and enhanced security features, it enables organizations to effectively manage their IT infrastructure, thereby boosting productivity and operational efficiency. As the demand for remote access increases, AdderLink IP remains a pivotal component in the evolution of IT management solutions.